Text

T. e

t

.

DEC 131985

Docket Nos. 50-317

50-318

Baltimore Gas and Electric Company

ATTN: Mr. A. E. Lundvall, Jr.

.

Vice President, Supply

P. O. Box 1475

Baltimore, Maryland 21203

Gentlemen:

Subject: Ccmbined Inspection Report Nos. 50-317/85-31 and 50-318/85-26

A routine radiological safety inspection was conducted on November 18 - 22,

1985 of activities associated with the 1985 outage at the Calvert Cliffs

Nuclear Power Plant, Units 1 and 2. Areas inspected included external dosimetry,

training, respiratory protection, exposuta control, surveys, procedures, out-

standing items, and posting and labeling. Also, the findings of the recent

Control Room Habitability review were discussed with members of your staff.

Within the scope of the review, no violations were identified. Radiological

controls implemented for outage work were acceptable. ALARA controls imple-

mented for installation of steam generator nozzle dams were commendable.

Section 11 of the enclosed inspection report identiffes deficiencies in the

area of Control Room Habitability. You are requested to reply to the

deficiencies within 30 days of the date of this letter.

The responses directed by this letter are not subject to the clearance pro-

cedures of the Office of Management and Budget as required by the Paperwork

Reduction Act of 1980, PL 96-511. Your cooperation with us in this matter is

appreciated.

Sincerely,

'

Original Signed ys

h *Y

3 homas T artin, Director

Division of Radiation Safety

and Safeguards

Enclosure: NRC Region I Combined Inspection Report Nos. 50-317/85-31 and

50-318/85-26

$k NO k

O

OFFICIAL RECORD COPY CC 85-31 - 0001.0.0

12/13/85 f

%

.

.

Baltimore Gas and Electric Co. 2

cc w/ enc 1:

R. M. Douglass, Manager, Quality Assurance

L. B. Russell, Plant Superintendent

Thomas Magette, Administrator, Nuclear Evaluations

R. C. L. Olson, Principal Engineer

J. A. Tiernan, Manager, Nuclear Power

R. E.~ Denton, General Supervisor, Training and Technical Services

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of Maryland (2)

bcc w/ enc 1:

Region I. Docket Room (with concurrences)

Management Assistant, DRMA (w/o enc 1)

DRP Section Chief

M. McBride, RI, Pilgrim

-T. Kenny, SRI, Salem

.D.'Jaffe, LPM, NRR

.

RI:DRSS RI:DRSS s

'

R- S

Cle /mjh/mmb/ft Bellamy Ma tin

Shanba

SLP ky(o-

12//7285 12/lb/85 12/0/85 12/))/85

0FFICIAL RECORD COPY CC 85-31 - 0002.0.0

12/12/85