Concurs w/850703 Assessment That Rev to Tech Specs for Max Closing Time Not Required Since Table 3.7.1 Requires 5 Stroke Time Limitation.Surveillance Tech Specs for Purge/Vent Valves Unnecessary
ML20138L749
Person / Time
Site: Peach Bottom  
Issue date: 10/24/1985
From: Stolz J
Office of Nuclear Reactor Regulation
To: Bauer E
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
References
NUDOCS 8510310397
Download: ML20138L749 (2)


Text

October 24, 1985 Dockets Nos. 50-277 DISTRIBUTION and 50-278

~ Docket file -

BGrimes NRC PDR JPartlow 4

1 Mr. Edward G. Bauer, Jr.

L PDR ACRS-10 Vice President and General Counsel ORB #4 Rdg Ringram Philadelphia Electric Company HThompson GGears i

2301 Market Street 0 ELD Gray File Philadelphia, Pennsylvania 19101 EJordan RGallo

Dear Mr. Bauer:

SUBJECT:

CONTAINMENT PURGE AND VENT Re:

Peach Bottom Atomic Power Station, Units 2 and 3 By letter dated July 3,1985 you responded to our request of February 20, 1985 to consider additions to the Peach Bottom Technical Specifications (TSs) to reflect the approved open position limitations and the maximum five second closing time limitation for all Peach Bottom containment purge and vent valves.

You have indicated in the above submittal that Table 3.7.1 (Primary Containment Isolation Valves) of the current Peach Bottom TSs requires a five second stroke time limitation and, therefore, a TS revision is not required for maximum closing time. We concur with your assessment.

In the same submittal, you proposed that the limitations on the open position for purge and vent valves be considered as design features and that these design changes be incorporated into the Updated Final Safety Analysis Report In the same submittal, you proposed that the limitations on the open position for purge and vent valves be considered as design features and that these design changes be incorporated into the Updated Final Safety Analysis Report I

(FSAR) with appropriate Bases. You have provided in this submittal together with follcw-up telephone conversations with the staff, the following details of the Peach Bottom mechanical stop design features:

The containment purge valve modifications incorporate a travel stop feature. A travel stop bar is attached to the valve push rod and is restrained by stud nuts. These stud nuts are to be welded to the studs to prevent tampering of the stroke limit settings.

i We find these design features are such that the approved stroke limit settings (i.e. valve open position limitations) will not change. Therefore, since these mechanical stops are design features which are permanent, that is, not removed or allured for any reason during all modes of operation, 4

based on our review of your proposal, we find that surveillance Technical 1

Specification for these valves are not necessary.

Sincerely, l

% c that naum Br Am J. 32%4*

8510310397e5M$77 John F. Stolz, Chief i

PDR ADOCK O PDR Operating Reactors Branch #4 P

Division of Licensing cc: See next page 0

OR L

GG r

JSto:

1 5

108 /85

Mr. E. G. Bauer, Jr.

Peach Bottom Atomic Power Station.

Philadelphia Electric Company Units 2 and 3 cc:

Mr. Eugene J. Bradley Mr. R. A. Heiss, Coordinator Assistant General Counsel Pennsylvania State Clearinghouse Philadelphia Electric Company Governor's Office of State Planning 2301 Market Street and Development Philadelphia, Pennsylvania 19101 P.O. Box 1323 Harrisburg, Pennsylvania l'i;20 Troy B. Conner, Jr., Esq.

1747 Pennsylvania Avenue, N.W.

Mr. Thomas M. Gerusky, Director Washington, D.C.

20006 Bureau of Radiation Protection Pennsylvania Department of Thomas A. Deming, Esq.

Environmental Resources Assistant Attorney General P.O. Box 2063 Department of Natural Resources Harrisburg, Pennsylvania 17120 Annapolis, Maryland 21401 Mr. Albert R. Steel. Chairman Philadelphia Electric Company Board of Supervisors ATTN: Mr. R. Fleishmann Peach Bottom Township Peach Bottom Atomic R. D. #1 Power Station Delta, Pennsylvania 17314 Delta, Pennsylvania 17314 Mr. M. J. Cooney, Superintendent Generation Division - Nuclear Philadelphia Electric Company 2301 Market Street Philadelphia, Pennsylvania 19101 Mr. Anthony J. Pietrofitta, General Manager Power Production Engineering Atlantic Electric P. O. Box 1500 1199 Black Horse Pike Pleasantville, New Jersey 08232 Resident Inspector U.S. Nuclear Regulatory Commission Peach Bottom Atomic Power Station P.O. Box 399 Delta, Pennsylvania 17314 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 l

\\

.-