Text
. _ _ _
October 17, 1985 Docket No. 50-334 DISTRIBUTION 4 Docket File /
NRC PDR L~PDR
- 0RB#1 Rdg i
Gray File HThompson Mr. J. J. Carey, Vice President 0 ELD PTam Nuclear Group EJordan CParrish Duquesne Light Company BGrimes JPartlow Post Office Box 4 ACRS 10 Shippingport, PA 15077
Dear Mr. Carey:
SUBJECT:
DRAFT TECHNICAL EVALUATION REPORT (TER) FOR SALEM ATWS ITEM 1.2, j
GENERIC LETTER 83-28 (LICENSING ACTION TAC 53569)
Re:
Beaver Valley Unit 1 We have completed a preliminary review to assess the completeness and adequacy of licensee responses to Generic Letter 83-28, Item 1.2.
For J
Beaver Valley Unit 1, your response was found to be incomplete in 3 of the
]
areas evaluated.
The enclosed TER provides a technical evaluation representing our initial judgment of the areas evaluated.
Pen and ink changes have been made to the TER to make the wording consistent with our approach.
In order to preserve our present review schedule, we would appreciate your i
cooperation in obtaining additional information that will permit us to complete our review. It would appear that the needed information on your j
facility could be obtained by telephone conference within one week of your receipt of the draft TER. Your project manager, Mr. P. Tam, will be i
working with you to arrara
'n acceptable time to conduct the necessary l
conference calls, i
}
Sincerely, i
/s/SVarga Steven A. Varga, Chief Operating Reactors Branch #1 Division of Licensing
Enclosure:
i Draft TER on Salem ATWS Item 1.2 cc w/ enclosure:
See next page ORBA1:DL ORB #1:0
- 1:DL
'(
l CParrish PTan;/85
- ps /
ar 10/$85 10/'g 10 35 l
i 8510310007 851017 PDR ADOCK 05000334 P
Mr. J. J. Carey Beaver Valley 1 Power Station Duquesne Light Company cc:
Mr. W. S. Lacey Mr. Thomas J. Czerpah Station Superintendent Mayor of the Burrough of Duquesne Light Company Shippingport Beaver Valley Power Station Post Office Box 26 Post Office Box 4 Shippingport, Pennsylvania 15077 Shippingport, Pennsylvania 15007 Pennsylvania Power Company Mr. K. Grada, Superintendent Ray E. Sempler of Licensing and Compliance One E. Washington Street Duquesne Light Company New Castle, Pennsylvania 16103 Post Office Box 4 Shippingport, Pennsylvania 15077 Ohio Environmental Protection Agency Division of Planning Mr. John A. Levin Environmental Assessment Section Public Utility Comission Post Office Box 1049 Post Office Box 3265 Columbus, Ohio 43216 Harrisburg, Pennsylvania 17120 Office of the Governor Gerald Charnoff, Esquire State of West Virginia N
Jay E. Silberg, Esquire Charleston, West Virginia 25305 Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.
Charles A. Thomas, Esquire Washington, DC 20036 Thomas and Thomas 212 Locust Street Karin Carter, Esquire Box 999 Special Assistant Attorney General Harrisburg, Pennsylvania 17108 Bureau of Administrative Enforcement
~
5th Floor, Executive House Irwin A. Popwsky, Equire Harrisburg, Pennsylvania 17120 Office of Consumer Advocate 1425 Strawberry Square Marvin Fein Harrisburg, Pennsylvania 17120 Utility Counsel City of Pittsburgh Governor's Office of State Planning 313 City-County Building and Development Pittsburg, Pennsylvania 15219 ATTN: Coordinator, Pennsylvania State Clearinghouse Resident Inspector Post Office Box 1323 U.S. Nuclear Regulatory Comission Harrisburg, Pennsylvania 17120 Post Office Box 298 Shippingport, Pennsylvania 15077 Mr. Jess T. Shumate, Comissioner State of West Virginia Department Department of Environmental Resources of Labor ATTN: Director, Office of 1900 Washington Street, East Radiological Health Charleston, West Virginia 25305 Post Office Box 2063 Harrisburg, Pennsylvania 17105 3
Duquesne Light Company Beaver Valley 1 Power Station cc:
David K. Heydinger, M.D.
State Director of Health State Department of Health 1800 Washington Street, East Charleston, West Virginia 25305 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Thomas M. Gerusky, Director Bureau of Radiation Protection Pennysivania Department of Environmental Resources P.O. Box 2063 Harrisburg, Pennsylvania 17120
}
- ~
- -