Application for Amend to License SNM-1665,authorizing 2 Test Instruments Located at Corporate Headquarters
ML20138J863
Person / Time
Site: 07002272
Issue date: 05/22/1978
From: Ellis J
PEABODY COAL CO. (SUBS. OF PEABODY HOLDING CO., INC.)
To: Jonathan Brown, Gilbert D
ARIZONA, STATE OF, US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20136B478 List: ... further results
References
FOIA-96-314 NUDOCS 9702130299
Download: ML20138J863 (7)


Text

.

. ' r.

3

)f).- f27,q l p^y

~_

PEABODY COAL COMPANY

';;K*#

3ol NORTH MEMORIAL DRIVE ST. LoulS. MISSOURI 631o2

)

//

USNRC

' (\\

g.g JUN 191978 ) pa C

W Nass

. ?2.1'./ ~

/R 9 38 i.wt secuct:

J 3Ccxtr Cta.c h

'O

\\

May 22,1978 y-7, ml 4

.. g. 4 N Mr. Joseph M. Brown, Jr.

Applicant,$. f k. fr'.. d//6..... l Radioisotopes Licensing Branch enos; b.9 (C...

,.mun;, r ce N;oguj.['/of.

U. S. Nuclear Regulatory Commission

.'iss!FJ b.+L A.# '

Washington, D. C.

20555

.Ma Check n, a'd.

(.:3

.l Mr. Donald C. Gilbert

"CU3d D > M * #N - {

I Executive Director v

Arizona Atomic Energy Commission 2929 West Indian School Avenue Phoenix, Arizona 85017 Gentlemen:

The purpose of this letter is to verify our recent conversations and to amend the U. S. and Arizona Licenses for several radioactive sources as outlined below.

A.

U. S. Nuclear Regulatory Commission Materials License: SNM-1665 It is our desire to be able to have two test instru-ments located at the Peabody Coal Company Cor-J porate Headquarters in St. Louis. These test in-struments contain two sources each or a total of four sources. These test instruments will be us-ed for occasional demonstration purposes and then stored. The instruments are:

RECElVED BY LFMB A.1 Sortex Company of North America Model Date.# /M.........

Phase II A and Model Phase III A-2 online

^

  • h M "it*'-

Thi* unit c**tni"* tw tag.bj.71.d-6.@.

Plutonium 238 Amersham /Searle Model By................. -

PPCL sources not to exceed 10 millicuries O rig. To................

each.

V Acttn Compi............

A.2 A Texas Nuclear Model 9200 Series por-table analyzer..This instrument contains two sources:

g 21 g 9 970106 e9460 NEITZEL96-314 pop

f

~

Page 2 May 22,1978 Mr.' Joseph M. Brown, Jr.

~ Radioisotopes Licensing Branch -

U. S. Nuclear Regulatory Commission Mr.. Donald C. Gilbert Executive Director 4

l Arizona Atomic Energy Commission 4

1.

Plutonium: 238 4

1 x 30 mil 11 curies, Amershan/

Searle Model PPCX 2.

Ame ricium: 241 1 x 0. 5 millicuries, Amersham /

i Searle Model AMM.4 B.

Arizona Atomic' Energy Commission License Peabody now operates one'Sortex Ash Analyzer at its Black Mesa Mine and intends within the next year to install two additional Sortex Phase III A-2 Ash Analyzers at the Black Mesa mining complex consisting of two mines, the Kayenta Mine and the Black Mesa Mine both located about 35 miles southwest of the city of Kayenta, Arizona. Peabody desires to be licensed to have:

B.1 Eight Plutonium 238, Amersham /

Searle Model PPCI sources not to exceed 10 millic.uries each. Six sources will be used in the Sortex analyzers and two will be used for demonstration or stored.

B. 2' A Texas Nuclear Model 9200 Series portable analyzer. This instrument contains two sources:

1.

Plutonium 238 1.x 30 mil 11 curies, Amersham /

Searle-Model PPCX

2. ' Americium 241 t'

t, Page 3 May 22,1978 Mr. Joseph M. Brown, Jr.

Radioisotopes Licensing. Branch U. S. Nuclear Regulatory Commission Mr. Donald C. Gilbert Executive Director Arizona Atomic Energy Commission 1 x 0. 5 millicuries, Amersham /Searle Model AMM. 4 We are attaching suggested word changes for both licenses and would be pleased to hear from you at your convenience.

i Very truly yours, Jack J. Ellis

Director, Analytical & Technical Services JJE: eh attachments cc: Mr. Kenneth S. Canfield Mr. M. M. Schindler Mr. John P. Smith

. AMENDhENT TO U. S. NUCLEAR ' REGULATORY COMMISSION MATERIALS LICENSE License Number: SNM-1665 L

6.

By product, sour'ce, and/or special nuclear material A.

Plutonium: 238 B.

Plutonium: 238 Americium: 241 7.-

Chemical and/or physical form A.

Scaled sources (Amersham /Searle Model PPCL)

B.

Amersham /Searle Model PPCX Amersham /Searle Model AMM.4 8.

Maximum amount that licensee may possess at any one time under this license A..

2 sources not to exceed 10 millicuries each B.

I x 30 millicuries 1 x 0. 5 -!!!L..... -

m. 'e
  • a'~ ~ '~

9.

Authorized use A.

To be used in a Sortex Company of North' America Model Phase III A and Model Phase III A-2 Coal Ash Analyzer to analyze ash content of coal. Sources will be used to demonstrate analyzer on an infrequent basis and primarily will be stored. The head unit a sketch of

.which is attached contains one half inch awr y

v ywiw-4

. ~

Page 2

' Amendment to U. S. Nuclear ' Regulatory Commis sion Materials License License Number: SNM-1665 thick steel on two of the four side s.

The third cide contains a graphite reference block and the fourth side is open to direct the sources onto the sample of '

c oal. Our intended use unit for demonstration purposes is to elevate the head unit about three inches over a metal table. Then to insert test trays of coal under the sources. At all other times the source holder will be rotated to face the safe steel side.

During storage the two sources will be placed in a one inch by two inch cylindrical lead storage holder and placed in a vault.

Radiation warning labels will be positioned at appropriate places.

The Texas Nuclear portable ana-lyzer containing the two source identified in 6. B. shall be used as designed by the manufacture for demonstration purposes.

The instrument head provides adequate shielding for the radio-active source.

10.

The licenced material shall be used only at the licensee's corporate headquarters located at St. Louis, Missouri.

12.

Licensed material shall be used by or under the su-pervision of Pete Bacchetti, Jack Ellis, James Addington or William Emke. Messers Bacchetti

.f

r 1

4 i

Page 3 Amendment to U. S. Nuclear Regulatory Commission Materials License License Number: SNM-1665 4

and Ellis have instructed Messers Addington and Emke in the proper use of the sources. We intend to have the instruction and maintenance manual present and follow the instructions for both test instruments at anytime the instruments are demon-strated or maintained.

1 13.

B. shall be modified to include that the test kit will be supplied by Texas Nuclear, Austin, Texas Kit Number QT/25 15.

Pete Bacchetti, Jack Ellis, James Addington and William Emke 17.

Also this letter requesting license amendment.

l i

i

l g '

,'4

. 3 O

t t

AMENDMENT TO ARIZONA ATOMIC ENERGY COMMISSION LICENSE FORM:

A EC - 313 (2-73) 10 CFR 30 4.

James H. Addington -

Manager,

(Jim)

Analytical Services

Director, Jack J. Ellis Analytical &

Technical Service s William B. Emke

Manager, (Bill)

Fuel Utilization Assistant Quality Kenneth Hallack Control Supervisor Supervisor, M. M. Schindler (Bill)

Quality Control 6.

A.

Plutonium: 238 Americium: 241 Plutonium: 238 B.

1 x 30 millicuries, Amersham /Searle i

Model PPCX 1

1 x 0. 5 millicuries, Amersham /Searle Model AMM. 4 8 x 10 millicuries, Amersham /Searle Model PPC L

,