ML20138D128

From kanterella
Jump to navigation Jump to search
Suppl 1 to NUREG-0737 Crdr,Addendum 2 to Summary Rept
ML20138D128
Person / Time
Site: Millstone 
Issue date: 11/30/1985
From:
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20138D101 List:
References
RTR-NUREG-0737, RTR-NUREG-737 NUDOCS 8512130158
Download: ML20138D128 (5)


Text

.-

_~

i i

i Docket No. 50-423 i

J Attachment No. I Millstone Nuclear Power Station, Unit No. 3 i

i f

I Supplement I to NUREG-0737

. Addendum No. 2 to Summary Report Control Room Design Review a

=

r i

t l

4

)

f f

8512130158 851114 PDR ADOCK.05000423 F

~

PDR November,1985 J

. =.

-o Millstone Unit No. 3 I

Control Room Design Review Summary Report Addendum No. 2 NUREG-0737, Supplement 1, NRC Task Action Plan requests all licensees of nuclear power plants and applicants for operating licenses to conduct a control room design review. This is Northeast Nuclear Energy Company's Addendum No. 2 to the Summary Report for its Millstone Unit No. 3 plant.

4 4

l I

1 t

~

~,

-. -.... ~.

.ai,,.-..,;c,

,,~,.,,. -,.. -.. -,,, - - '

Table of Contents Introduction Section 1.5.3 - Environmental, Computer and Communications Surveys o

Methodology o

Findings and Corrections 1

i

Introduction This document constitutes Addendum No. 2 to the Control Room Design Review (CRDR) Summary Report for Millstone Unit No. 3.

This report documents the results of the eleven (11) checklist open items identified in Addendum No. I to the CRDR Summary Report, which was submitted to the NRC Staff on September 12, 1985. The following section corresponds to the same section in Addendum No.1.

Section 1.5.3 - Environmental, Computer and Communications Surveys Methodology Addendum No. I to the Summary Report indicated that the control room had been reviewed against Sections 6.1, 6.2 and 6.7 of NUREG-0700 with the exception of the following eleven (11) checklist items:

6.1.5.1 Temperature and Humidity 6.* 5.2 Ventilation 6.1-5.3 Emergency Lighting 6.2.1.2 Conventional Powered Telephone System 6.2.1.3 Sound Powered Telephone System 6.2.1.6 Announcing System 6.2.1.8 Emergency Communications 6.2.2.1 Use of Auditory Signals 6.7.1.7 Computer Response Times 6.7.1.8 Access Aids 6.7.2.7m(l)

Red-Green Combinations

,.. The review of the control room against these checklist items has been completed.

Findings and Corrections 4

1 The checklists produced two (2) additional HEDs: HED No. E-01 against the Ventilation Section and HED No. CM-02 against the Announcing System Section.

Specifically, HED No. E-01 identified an excessive air velocity in one area of the control room and is currently being corrected by balancing the ventilation system. HED No. CM-02 concerns " dead spots" in the announcing system in some areas of the plant (i.e., outside the control room). This HED has been assigned a j

Priority 2, Code A and will be corrected prior to commercial operation.

?

l

-<n-

- -.. - -. - -