ML20137Y117

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amend 6 to License NPF-35
ML20137Y117
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 02/24/1986
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20137Y111 List:
References
NUDOCS 8603120144
Download: ML20137Y117 (10)


Text

,

na a%

o UNITED STATES

^g 8

NUCLEAR REGULATORY COMMISSION g

WASHINGTON, D. C. 20555 rj

%,...../

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO.6 TO FACILITY OPERATING LICENSE NPF-35 CATAWBA NUCLEAR STATION, UNIT 1 DUKE POWER COMPANY NORTH CAROLINA ELECTRIC MEMBERSHIP CORPORATION SALUDA RIVER ELECTRIC COOPERATIVE, INC.

. INTRODUCTION By letters dated March 15, August 7 October 30, November 7, December ll, December 20, and December 23, 1985, Duke Power Company (DPC or Licensee) pro--

posed changes to the Catawba Unit I facility Technical Specifications to eliminate typographical errors, provide additional clarification, improve consistency, adjust nomenclature, bring portions of the Specifications into confonnance with current NRC staff positions, incorporate Unit 2 Specifications where appropriate, and make other minor changes.

The NRC staff renumbered many pages to accommodate the additional specifications needed for Unit 2.

The changes included in this amendment do not cover all the changes requested by Duke Power Company; some of the changes not included in this amendment are still under consideration by the NRC staff.

A primary objective of this amendment is to achieve a single Technical Specifications document that is comon for the nearly identical Units 1 and 2 with individual specifications for each Unit clearly identified, as appropriate.

EVALUATION The NRC staff has reviewed the licensee's submittals dated March 15, August 7, October 30, November 7, December 17, December 20, and December 23, 1985, and finds'that their primary objective is to achieve a single Technical Specifications document that is comon for Catawba Units 1 and 2 facilities because these units are nearly identical although there are some differences in design. The operating staff was licensed on both units, with a designated crew h fh P

! l assigned and dedicated to each unit on each shift. The licensee concluded that the Technical Specifications for both units can and should be identical to a great extent. Accordingly, the licensee proposed one set of Technical Specifi-cations, common to both units, with unit-specific specifications due to differences in design and operations appropriately identified.

The proposed changes have been evaluated by the NRC staff, and only those changes that are found acceptable are being issued as ar amendment to Catawba Unit 1 Facility Operating License NPF-35 concurrent wich the issuance of the 4

Catawba Unit 2 Facility Low-Power Operating License NPF-48.

These proposed changes will revise the previous Catawba Unit 1 Facility Technical Specifi-cations to make them identical to those to be issued with the Catawba Unit 2 Facility Low-Power License with unit-specific specifications clearly identified. Thus, Appendix A to the operating licenses for Units 1 and 2 J

facilities will be identical.

The following items provide descriptions and justifications of the proposed changes to the current Unit 1 Facility Technical Specifications:

1.

Page V of the Table of Contents is revised to change page numbers for two figures that have been rearranged for a more consistent format.

2.

Page VII of the Table of Contents is revised to indicate that a new section 3/4.4.11 has been added.

3.

Page 2-2 Specification 2.1, Figure 2.1-1, "1700 psia" is changed to "1775 psia" to corre::t a typographical error.

4.

Pages 2-5, 3/4 3-21, and 3-31, Specifications 2.2.1 and 3.3.2, Tables 2.2-1 and 3.3-3 are revised to incorporate Unit 2 trip setpoints.

5.

Page 2-8, Specification 2.2.1, Table 2.2-1 is revised to read "590.8'F (Nominal T,y allowed by Safety Analysis)" for clarification of a parenthetica statement.

. 6.

Page 2-8, Specification 2.2.1, Table 2.2-1 is revised to read "q

-9b IS t

is more positive than -6.5%"

more negative than -43%," and to read "qt -9b to clarify the nomenclature by replacing the word " exceeds."

7.

A new page 3/4 0-2, Specification 3.0.5 is added as a clarification to specify the applicability of all specificatiens to Units 1 and 2 individually and jointly.

8.

Page 3/41-12, Specification 3.1.2.6 is revised to correct a typographical error in the specification number.

9.

Page 3/4 2-7, Specification 4.2.2.2 is revised to replace "F

=F xy xy

[1+0.3(1-P)]" with "F

=F f1+0.2(1-P)]" to correct a typographical error.

xy xy 10.

Pages 3/4 2-6 through 2-8 are rearranged and renumbered for a more consistent format.

11.

Pages 3/4 2-10 and 2-11 are rearranged and renumbered for a more consistent format.

12. Pages 3/4 3-3, 3-8, and 3-10, Specifications 3.3.1. and 4.3.1.1, Tables 3.3-1, 3.3-2, and 4.3-1 are revised to incorporate Unit 2 specific values.
13. Pages 3/4 3-15, 3-23, 3-27, 3-34, 3-37, 3-38, 3-39, 3-42, 3-49, and 3-53, Specifications 3/4.3.2, and 3/4.3.3, Tables 3.3-3, 3.3-4, 3.3-5, 4.3-2, and 3.3-6 are revised to delete the word " ventilation" for a functional unit to correct and clarify the nomenclature of the functional unit.
14. Pages 3/4 3-18 and 3-19, Specification 3.3.2, Table 3.3-3 is revised to replace the word " loop" with " steam generator" to clarify the nomenclature for the actual system.
15. Page 3/4 3-21, Specification 3.3.2, Table 3.3-3 is revised to correct a typographical error by replacing an instrument number "5231" with "5232".

r

. 16. Page 3/4 3-26, Specification 3.3.2, Table 3.3-3 is revised to add the words "with flow through the HEPA filters and carbon adsorbers" at the end of ACTION 24 to correct an inconsistency with other specifications.

17. Pages 3/4 3-29 through 3-32, Specification 3.3.2, Table 3.3-4 is revised to replace the symbol for "less than" with the symbol for "less than or equal to to correct a typographical error and to incorporate Unit 2 d

specific trip setpoints.

18. Page 3/4 3-40, Specification 3.3.2, Table 3.3-5 is revised to delete "N/A" from line containing "13.

Loss-of-Offsite Power" to correct a typographical error.

19.

Page 3/4 3-41, Specification 3.3.2, Table 3.3-5 is revised to clarify that the KC valves apply to both Units 1 and 2 to correct an inconsistency for equipment designation.

20.

Pages 3/4 3-52 and 3-54, Specification 3.3.3.1, Tables 3.3-6 and 4.3-3 are revised to replace " EMF-15" with "1 EMF-15, 2 EMF-4" to incorporate a Unit 2 design difference and to replace "All" with "1,2,3,4" under applicable modes for functional uns; item 4 to correct an inconsistency with other specifications.

21.

Page 3/4 3-53, Specification 3.3.3.1, Table 3.3-6 is revised to replace

" charcoal" with " carbon" in ACTIONS 31, 34, and 35 to ensure the consistency of the nomenclature for adsorbers.

22.

Pages 3/4 3-62 and 3-65, Specifications 3.3.3.5 and 3.3.3.6 are revised to replace " HOT SHUTOOWN within the naxt 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />" with " HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />" to correct an inconsistency in the ACTION item with other specifications.

23. Pages 3/4 3-67 and 3-69, Specifications 3.3.3.6 and 4.3.3.6, Tables 3.3-10 and 4.3-7 are revised to replace "(EMF-26, 27, 28, or 29)" with "(1 EMF-26, 27, 28, or 29 and 2 EMF-10,11,12, or 13)" to incorporate Unit 2 design differences.

. 24.

Page 3/4 3-70, Specification 3.3.3.7, is revised to replace " system" with

" System" to correct a typographical error in reference to the Chlorine Detection System.

25.

Page 3/4 3-71, Specification 4.3.3.8, is revised to replace " fire detection" with " smoke detection or flame detection " to replace the words " Fire detectors" with " Detectors," and to replace the words " fixed temperature / rate of rise" with " heat" to make the specification consistent with the correct nomenclature used in Table 3.3-11, 26.

Pages 3/4 3-73 to 3-76, Specification 3.3.3.8, Table 3.3-11 is revised to add multiple fire detection instruments and locations for Unit 2 and to correct typographical errors.

27.

Pages 3/4 3-79, Specification 3.3.3.10, Table 3.3-12 is revised to replace

",1" with "I per station" in 1.a., 2., 3.a., 3.b., and 3.c. to clarify applicability of instrumentation on a station basis.

28. Page 3/4 3-82, Specification 4.3.3.10, Table 4.3-8 is revised to corrs,t a spelling error in "CHAht:dL".
29. Page 3/4 3-84, Specification 3.3.3.11, Table 3.3-13 is revised to replace "1" with "1 per station in 1.a. and 1.b., and to replace "1/ train" with "1/ train per station" in 2.a., and "2/ train" with "2/ train per station" in 2.b. to clarify the applicability of systems to both units.

30.

Pages 3/4 3-77 to 3-84 have been renumbered to accommodate additional equipment for Unit 2 incorporated into pages 3/4 3-73 to 3-76.

31. Page 3/4 4-10, Specification 3.4.4, ACTION c. is revised to replace "With both PORV(s)" with "With more than one PORV" to clarify the action statement for a plant containing more than 2 PORVs.

32.

Page 3/4 4-17, Specification 4.4.5.1, Table 4.4-1 has multiple revisions to clarif.y the information regarding Catawba as a plant with 4 steam generators.

6-

33. Pages 3/4 4-22 and 4-23, Specification 3.4.6.2, Table 3.4-1 is revised to l

clarify the applicability of the valves to both units, and to correct typographical errors.

2

34. Page 3/4 4-40, a new Specification 3.4.11 is added to provide the Limiting Condition for Operation and Surveillance Requirements found in NUREG-0737 for the Reactor Coolant System Vents.

35.

Page 3/4 5-4, Specification 4.5.1.2 is revised to replace "...the water l

level is 93.2'[plus or minus) 2.7 inches above...." with "...the water level is 93.2 [plus'or minus) 2.7 inches (Unit 1) and 93.1 [plus or minus) 2.7 inches (Unit 2) above..." to incorporate Unit 2 specifications.

36.

Pages 3/4 5-6 and 5-7, Specification 4.5.2 is revised to replace "1NI" with "NI" to clarify the applicability of the valves to both units.

37.

Page 3/4 6-7, Specification 3.6.1.2, Table 3.6-1 is revised to include a Unit 2 specific penetration and a footnote regarding its applicability to i

Unit 1.

38.

Pages 3/4 6-14, 6-15, 7-13, 7-14, 7-15, 9-5, 9-6, 9-14, and 9-15 j

Specifications 4.6.1.8, 3.7.6, 4.7.6, 4.9.4.2, 4.9.11.1, and 4.9.11.2 are i

revised to replace the word " charcoal" with " carbon" to ensure the consistency of the nomenclature of adsorbers.

39.

Page 3/4 6-17, Specification 4.6.1.9.4 is revised to replace " Containment Air Release and Addition System" with " Containment Air Release and Addition

}

System valves" to correct a typographical omission.

l

40. Pages 3/4 6-15, 7-14, 7-17, 9-6, and 9-15, Specifications 4.6.1.8, 4.7.6, 4.7.7, 4.9.4.2, and 4.9.11.2 are revised to delete "when tested in accordance with ANSI N510-1980" because this ANSI standard does not have test procedures for heat dissipators.

l

,mmn..

n-_-

.,.-,_,_,_._,_n n,,,-

, 41. Pap 3/4 7-1, Specification 3.7.1.1 is revised to replace " COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />" with " HOT SHUTOOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />" to make the ACTION statement consistent with the APPLICABILITY statement for this Specification and the Standard Technical Specifications.

42. Page 3/4 7-3, Specification 3.7.1.1, Table 3.7-2 is revised to replace "1SV" with "SV" to clarify the applicability of the valves to both units.
43. Page 3/4 7-5, Specification 4.7.1.2.1 is revised to correct a typographical error by moving "and" from before paragraph 4) to before paragraph 5).
44. New page 3/4 7-9, Specification 3/4.7.1.3 is added to implement a Limiting Condition for Operation and Surveillance Requirements for the Unit 2 Condensate Storage Tank. Pages 7-9 through 7-41 are renumbered to reflect this addition, and Table of Contents Page IX is corrected to include the new Specification. This Specification does not apply to Unit 1; therefore, this change is purely administrative for Unit 1.

45.

Pages 3/4 7-12 and 7-13 Specifications 3.7.5 and 3.7.6 are revised to indicate that the specifications apply to both units.

46. Page 3/4 7-14, Specification 4.7.6e.3) is revised to clarify the relative pressure measurement requirement across the HEPA filter in the control room area ventilation system.

47.

Page 3/4 7-27, Specification 4.7.10.1 is revised to correct a spelling error for " distribution".

48.

Page 3/4 7-28, Specification 3.7.10.2 is revised to incorporate spray /

sprinkler systems for Unit 2.

49.

Pages 3/4 7-33 and 7-34, Specification 3.7.10.4, Table 3.7-3 has multiple revisions to incorpc* ate Unit 2 additions, and to correct a typographical error.

50. Pages 3/4 8-12, 8-13, 8-14, 8-16, and 8-17, Specifications 3.8.2.1, 4.8.2.1.1, 3.8.2.2, and 3.8.3.1 are revised to delete reference "1" from Bus and Battery Numbers to clarify the applicability to both units.
51. Pages 3/4 8-19 and 8-21 through 8-43, Specification 3.8.4 and Table 3.8-1 have been revised and new pages 3/4 8-44 through 8-66 have been added to establish separate tables for Units 1 and 2 and to correct typographical

]

errors.

52.

Pages 3/4 8-24 and 8-26, Specification 3.8.4, Table 3.8-1 is revised to delete containment penetration conductor overcurrent protective devices to match the as-built plant.

i 53.

Pages 3/4 8-35 and 8-43, Specification 3.8.4, Table 3.8-1 is revised to identify additional containment penetration conductor overcurrent protective devices originally omitted from the table.

54.

Page 3/4 8-40, Specification 3.8.4, Table 3.8-1 is revised to correct a

)

typographical error.

55. Page 3/4 11-2. Specification 4.11.1.1.1, Table 4.11-1 is ievised to correct a typographical error by removing "a." under 2.

1

56. Page 3/4 11-18 Specification 3/4.11.3 is revised to correct a typographical error in the heading of the Specification.
57. Page 5-3, Specification 5.1.2, Figure 5.1-2 is revised to indicate that the Low Population Zone is 3.8 miles instead of 5.0 miles to conform with the Final Safety Analysis Report.

1 58.

Page 6-1, Specification 6.2.2 is revised to include standard wording for a two unit station, i

f i

. 59. Pages 6-3 and 6-4, Specifications 6.2.1 and 6.2.2, Figures 6.2-1 and 6.2-2 have been revised to incorporate the current structures for offsite and unit organizations.
60. Page 6-5, Specification 6.2.2, Table 6.2-1 is revised to incorporate wording for a two unit station with a comon control room.

61.

Page 6-17, Specification 6.9.1.7 is revised to clarify classification of shipped solid. waste as it pertains to 10 CFR Part 61.

The staff finds that proposed changes 1 through 33, 35 through 43, and 45 through 61 to the Catawba Unit 1 Facility Technical Specifications are administrative in that the objectives of the changes are to eliminate typo-graphical errors, provide additional clarification, improve consistency throughout the Technical Specifications, adjust nomenclature, bring portions of the Specifications into conformance with current NRC staff positions, in-

' corporate Unit 2 Specifications where appropriate, and make other minor changes.

Proposed change 34 introduces an additional Technical Specification to address reactor coolant system vents. Guidance for reactor coolant system vents is found in NUREG-0737 as post-TMI requirements.

This Specification details the Limiting Condition for Operation and Surveillance Requirements for the vents. Thus, proposed change 34 constitutes an additional limitation not previously included % Catawba Unit 1 Technical Specifications. The staff finds that this change enhances safe operation and is, therefore, acceptable.

Proposed change 44 is added to implement a Limiting Condition for Oper-ation and Surveillance Requirements for the Catawba Unit 2 Facility Condensate Storage Tank. This specification does not apply to Catawba Unit 1.

The staff has evaluated the proposed changes and concluded that, with the exception of item 34, they are purely administrative in nature and do not change any substantial requirement or safety parameter or otherwise affect operation of the Catawba Unit 1 Facility and are, therefore, acceptable.

With respect to item 34, as described above, that change is an additional limitation which enhances safe operation and is, therefore, acceptable.

I e

0 ENVIRONMENTAL CONSIDERATION The amendment involves a change in use of facility components located within the restricted area as defired in 10 CFR Part 20, changes in surveil-lance requirements, and changes in administrative procedures or requirements.

The staff has determined that the amendment involves no significant increase in the amounts, and no signficant change in the types, of any effluents that may be released offsite and that there is no significant increase in individual or cumulative occupational exposure. The Comission has previously issued a proposed finding that the amendment involves no significant hazards consider-ation, and there have been no public coments on such finding. Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR Sections 51.22(c)(9) and 51.22(c)(10). Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

CONCLUSION The Comission made a proposed determination that the amendment involves no significant hazards consideration which was published in the Federal Register (51 FR 455) on Jan.uary 6,1986, and consulted with the state of South Carolina.

No public coments were received, and the state of South Carolina did not have any coments.

We have concluded, based on the considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the' proposed manner, and (2) such activities will be conducted in compliance with the Comission's regulations, and the issuance of the amendment will not be inimical to the comon defense and security or to the health and safety of the public.

Principal Contributors:

Kahtan Jabbour, PWR#4 Stewart Brown, FOB, PWR-A Michael Wangler, F08 PWR-B Dated: February 24, 1986

.