Enclosure SAFETY EVALUATION REPORT Haddam Neck Plant IPSAR Section 4.1.4(1) Emergency Procedures - Flooding 1.0 Introduction In Section 4.1.4(1) of the Integrated Plant Safety Assessment Report (IPSAR) for Haddam Neck, NUREG-0826, the staff reconsnended that the river level for initiation of emergency procedures for rising flood water be reduced. The licensee proposed to assess the time required to implement flood protection actions to determine whether the river levels selected to initiate various portions of the procedure are appropriate and to demonstrate that sufficient time is allowed by a walk-through of the procedures.
2.0 Discussion The staff observed a demonstration of installation of the flood protection devices at Haddam Neck in November 1983. This demonstration was intended primarily to verify system capability and availability of equipment and procedures rather than speed of installation.
In fact some of the protection was partially installed prior to the demonstration, However, based on observations of licensee controls of procedures anJ equipment and on assessment of the required actions, the staff concludes that it is reasonable to expect that the protection devices could be installed within one shift (8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />) of flood warning.
The staff also reviewed the licensee's flood emergency procedures, as revised in June 1984 following a high river level event. This procedure, Abnormal Operating Procedure A0P 3.2-24, " Flooding of the Connecticut River", establishes the following:
"4.4 When forecasts indicate a level of 21.0 feet (MSL) will be reached and when the river reaches elevation 16.0 feet (MSL), dispatch personnel to install the following flood protection barriers as detailed in Figure 1 Attachment "A" to this procedure."
This step makes the licensee's response to flooding dependent on forecasted flood levels. Therefore, the staff evaluated the accuracy of the flood level l
forecasts, the transfer of forecasted levels from upstream locations to the site and the timing requirements.
i 3.0 Evaluation 3.1 Prediction of Flood Levels by NWS. The National We (NW5) River Forecast Center, Hartford, Connecticut yher Service
, issues flood I
l warnings and predicts flood levels at several locations along the M ctually located in Bloomfield, Connecticut, 3 miles north of Hartford's A
northern city limits.
8510030211 850924 PDR ADOCK 05000213 F
i Connecticut River and its tributaries. These on empirical relations between precipitation (predictions are based rainfall and snow),
measured upstream river flow and the predicted downstream river flow. There is no formal documentation of the present model configuration other than the computer program in the NWS inhouse computer in the Bloomington, Conn. office. Also, there is no formal documentation of the development of the program.
From a telephone discussion (9/5/84) and visit to the NWC River Forecast Center (12/19/84) it was learned that the Connecticut River Basin flood forecastmodelwasdevelopedbetweenIg55and1965. The basin is divided into subareas of 250-500 mi for which unit hydrographs were developed using data from about 5000 storm events. A discharge i
i from each st.barea is calculated from the measured precipitation, an antecedent precipitation index (API) and the unit hydrograph, and is then routed downstream with a Muskingum routing procedure.
When the river system is flooding all dams are assumed to store the flood flow and just release at the base flow rate.
Information from about 100 precipitation gages and 12 river gaging stations is used in an interactive way during a flood event to refine the forecasts.
In general, the Connecticut River Basin flood forecasting system is analogous to one for the Susquehanna River Basin that has been described in good detail (Susquehanna River Basin Comission,1979).
When flow rate (i.e., cubic feet per second) has been forecasted for a particular location along the river, it is converted to a level of flooding by using a rating relation for that location, and that level is broadcast to the public.
As may be appreciated, such a forecast model has many possibilities for errors in arriving at the final prediction. The NWS has no error evaluation for their Connecticut River Basin model and thus are not able to provide any confidence limits for their predictions.
An error evaluation (Burn and McBean,1985) for a river flow forecasting model of the Sturgeon River gives some indication of what prediction accuracy coyld be expected. The Sturgeon River basin drains about 2,700 mi area in the Canadian shield region of northern Ontario. The Congecticut River basin above Haddam Neck has an area of about 10,900 mi (Franklin Research Center,1982). Thus the Sturgeon River basin is about one fourth the size of the Connecticut River basin and probably has more contribution to runoff from snow; however, the results of the error analysis for their Kalman filter model are indicative of what might be determined for NWS Connecticut River forecast model if it were to be rigorously analyzed. The Kalman filter model combines two independent estimates of system state _to produce an optimal or minimum variance estimate, and they have successfully used precipitation and streamflow measurements to update model parameters, noise component estimates and short-tenn forecasts (Haan et al.,1982).
In a general sense, the NWS Connecticut River flood prediction model functions similarly to a Kalman filter model. The peak flow predictions had errors ranging from 2 to 19 percent with an average of 11 percent.
I
- {
For six selected flood events on the Connecticut River a comparison was made (Table 1) of the NWS predicted flood level and measured i
flood level at the Middletown (Bodkin Rock) gage which is 9.6 river l
miles upstream of the plant. - The information in Table 1 shows that predictions of flood levels varied from -17 to +15 percent from the i
measured peak levels with a negative indicating a low prediction and a positive a high prediction.
Errors in peak flow predictions cannot be compared directly with those of elevation predictions because of the rating relation between flow and stage (elevation).
Copies of the NWS flood forecasts, from which the infomation for Table 1 was obtained, are assembled in Appendix A.
3.2 Transfer of NWS Forecast to Haddam Neck. The NWS flood level prediction for Middletown needs to be converted into a discharge or flow rate (See Rating Relation, Appendix B) and then this flow value (without any attenuation) is transferred to the Haddam Neck site (9.6 river miles downstream). This discharge is converted back into a flood level by using a stage-discharge relation developed specifically for the river reach beside the plant. This rating relation and an evaluation of transferring flow values to the Haddam Neck site were made by the Licensee and their report is appended in l
Appendix B.
In general additional errors can be introduced in translating flood levels to discharge and then back to flood levels.
L Magnitudes of these errors have not been quantified; thus additional margin must be considered to acconnodate these errors.
i 3.3 Flood Warning Time. The information for the six selected events in Table I shows that nominal.24 and 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> flood forecasts are made.
In general the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> forecast is a refinement and is improved over i
the 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> forecast.
r
?
The licensee's Abnormal Operating Procedure AOP 3.2-24 calls for initial reactions to flood warnings received from " Convex" and "USGS River Forecasting Center" at a river level 12.0 ft (msl) or greater.
A minor point is that "USGS" should be corrected to NWS. Presently the Haddam Neck control room receives the NWS forecasts through the i
Connecticut Valley Electric (Convex) or indirectly through the F
public news media. Two memoranda (June 24, 1982 and July 20,1983) cover the dissemination of weather infonnation from Convex to the
)
power plant control room supervisor or operator. Presumably, floods
}
are included among the events for which warnings would be conveyed to the control room operators, but they are not explicitly mentioned (See Appendix C for copies of these memos).
Connunication channels between the Haddam Neck control room and Convex are varied and redundant (2 dedicated phone lines, 2 restricted outside phone lines for which Convex has the numbers, i
normal connercial phone line and a two-way radio connection). The staff-concludes that infonnation can be conveyed from Convex to the operators in the control room. However, there may be delays involved between receipt of warnings by Convex and their notification of the Haddam Neck operator. Since Convex concerns are primarily associated with power distribution and the influence of
[
severe weather on the power grid and transmission lines,-their focus is not on reconveying flood forecasts. The need for sending flood
forecasts to the control room operators could be made explicit in Convex's memoranda. A further improvement would be to have the control room operator contacted directly by the NWS with their flood forecast. The restricted phone numbers could be given to the NWS and used by them for a direct notification. The NWS provides such services to others. Another advantage from the direct contact with NWS Flood Forecast Center would be that they could provide the estimated discharge value at the Middletown gage which in turn could be used directly in the Haddam Neck rating relation for a prediction of flood level. This arrangement would eliminate the step of converting predicted flood levels at Middletown to discharge.
Since the plant has demonstrated that they can install the flood protection within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, flood warning times of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, even if there would be several hours of delay in conveying the warning to the plant operators, are adequate for providing the necessary flood protection at the plant. However, warning time could be improved by providing direct consnunication between the NWS and control room operator as discussed above.
4.0 Conclusions and Reconsnendations Based on review of the licensee's flood protection procedures and the forecasting capabilities, the staff concludes that Section 4.4 of AOP 3.2-24 should be revised to read "4.4 When forecasts indicate a level of 19.0 feet (MSL) will be reached and when...".
This change would direct implementation of flood protection barriers at a lower level than at present and is intended to ac;:ount for uncertainties in forecasting and transmittal of forecast information. Witn this change, the staff finds the licensee's procedures for responding to river flooding acceptable.
In addition, the staff offers the following reconinendations to improve the procedure:
a)
Correct line 2.2 of AOP 3.2-24 by changing USGS to NWS.
b)
Arrange for the NWS River Forecast Center to directly notify the Haddam Neck Control Room operator with their flood predictions for the Middletown gage site.
1 c)
Arrange for the NWS River Forecast Center to give the operator the flood prediction at the Middletown gage in terms of discharge which in turn can be used directly with the Haddam Neck rating relation to detennine the forecasted flood level at the plant.
d)
Revise the Convex memoranda to explicitly mention flood level forecasts and the appropriate dissemination of this information, e)
Prepare appropriate rating relations and tables with l
instructions and attach to the A0P so that the flood level or flood discharge forecasts can inunediately be translated into flood levels at the plant.
l
5.0 References Burn, D. H. and E. A. McBean,1985, " River Flow Forecasting Model for Sturgeon River," Jour of Hyd. Engr. ASCE 111:2, Feb.
Franklin Research Center,1982, " Hydrologic Considerations (SEP, II-3A, 8.1, C; III-3B) Connecticut Yankee Atomic Power Company Haddam Neck Plant," NRC Docket No. 50-213, NRC Contract No. NRC-03-79-118 June 25, Revised August 27 transmitted by letter dated September 10, 1982 (D.
Crutchfield to W. Counsil)
Susquehanna River Basin Comission,1979, " Flood Forecast and Warning System Evaluation Susquehanna River Basin New York, Pennsylvania and Maryland," Report of an Interagency Task Force for the U.S. Army Corps of Engineers, Baltimore District, January.
Haan C.
T., H. P. Johnson, D. L. Brakensick, " Hydrologic Modeling of Small Watersheds," ASAE Monograph No. 5, American Society of Agriculture Engineers, 1982.
I
Table 1.
Comparison of Selected Flood Stages and NWS Forecasted Flood Stages at Bodkin Rock (Near Middletown)
Gage, Connecticut River Measured 24 Hr Forecast 48 Hr Forecast 72 Hr Forecast Flood Peak Date Peak Stage Date H(est)
Error Date H (est)
Error Date H(est)
M/D/Y Time (ft asi)
Time T (est) of H Time T (est) of H Time T (est) 04/04/76 13:00 13.5 04/03/76 04/02/76 04/01/76 10:26 13-14 (14) 11:03 13-14 (14) 21:44
- 15 04/1-13 04/AM 04/AM 03/16/77 13.8 03/15/77 03/14/77 10:51 13\\
(-2) 09:16
- 12
(-13) 16/PM 16/AM 10:22 sil\\
(-17) 16/AM 02/27/81 s11:00 13.0 02/26/81 02/25/81 02/24/81 11:22 15-15\\
(+15) 11:48 Nr 11
(-15) 11:04 Nr 12 Dur 27 26/ErAM 25/AM 12/17/83 11.7 12/16/83 12/15/83 12/14 11:36 11
(-2) 11:21 12
(+2) 22:24 Nr 10 17/AM 16/PM 16 04/09/84 7:00 12.4 04/08/84 04/s '/84 04/06/84 05:00 12\\-13
(+1) 11:15 12\\-13
(+1) 11:18 10\\-11 09/ErAM 08/PM 07/PM 06/02/84 7:00 21.3 06/01/84 05/31/84 05/30/84 11:48 21-22
(-1,+3) 12:00 Nr 21
(-1) 10:40 13-14t 02/AM,
02/ErAM 05-31/AM+
22:46 Nr 21
(+1) 23:21 Nr21
(-1) 17:40 15-16 02/AM 02/ErAM 05-31/AM+
23:03 To 19 01/AM ktageinfeet Nr = Near
% Error = (H est - Measured Peak Stage)
T = Time Day / Time of Day t = or Higher 100 (Measured Peak Stage)
Dur = During day indicated
+ = or later Er = Early
4 APPENDICES
4 Appendix A National Weather Service Ferecasts for Selected Flood Events e
e
l l
CON 3ICTITI IIVER FID0D CREST STAGES t
at Bodkin Rock naar Middletown, Conn. (USGS gage)
Flood Stage 8 f t.
8cDo# Rock
?
Stage l
Tear Date (feet) i i
1814 21.4
- 1848 20.8
- 1854 23.4
- I 1860 20.8
- i 1861 20.2 e 1
1927 20.3 *
. E 1936 h rch 21 28.2 8
! M 1938 Sept. 23-24 15.8
- l 1947 bril 15 11.8 1948 brch 14 16.1 l
1949 Jan.
2 16.7 l
1950 April 7-8 10.1 1
1951 April 2, 5 13.6 1
1952 June 4
13.4 1953 hrch 30 16.7 g
1954 April 20 10.2 1955 Aug. 20 20.4 195F Oct. 17 13.9 1957 Jan. 26 7.3 l
1958 April 25 13.8 1959 April 6 12.2 t
- 1960 April 7 18.7 b 1961 4ril 26 9.4 I
1962 April 3 12.9 l
1963 April 5 11.7 1964 April 17 11.1 1965 April 19 4.8 1966 hrch 28 7.3
{
1967 April 5 93 1968 hrch 26 12.4 1969 April 24 14.4 V g
- 1970 April 28 9.7 p 1971 hy 7
9.6 1972 May 7
11.7 1973 July 3
12.1
- Taken from Eish Water b rks 6
4
, b h
IP
.i 4
?
- S+
3 J
CONNECTICUT RIVER FLOOD CRESTS AT MIDDLETOW, CONNECTICUT Flood Stage 8 ft.
b Bodkin Rock Cage
~'
Year Date Stage (feet)
N 1974 April 7 9.3 1975 October 22 10.9 y
1976 April 4 13.5 / o l.C0 ni J
2 1977 March 16 13.8 7 1978 January 11 8.4 3
1979 March 8 12.5 1
1980 April 12 10.8
- 4 1981 February 27 13.0 / 15 t '. "
c' 7,1982 April 20 11.5 1982 June 8 11.2 1983
["1983 April 21 10.6 as December 17 11.7 p
1984 y April (8 12.4 2
1984 W June 1 21.3 (D4 NYt LA14) i '.
g s wt4 paid w A A
- l'
,,,,n a, 1 4 h e k a m 4
@ 4tNr. M c'N tt l
1
]
i r
h hl k 5b 'S 4
l0}&; h)fI
'00
$ 0* $
/
a.a e
ZCZC WRUS RWRA 012201 FISSSSSSSSSZZZZZ BULLETIN NOAA tJO THEAST RIVER FORECAST CE:!TER 1701EST THUR 4/ 1/76 FLOOD WARNING BULLETIN HEAVY RAINS IN THE C0t:NECTICUT RIVER BASI:3 I!: THE LAST 24 HRS '4ILL e
PRODUCE SIGNIFICAt:T FLOODING ALO::3 THE CD::NECTICUT RIVER THROU3HT M ASSACdUSETTS AND C0t:NECTICUT. I:: THE t:0RTHER:: PARTOF THE BASIt: RAI:S ARE STILL CONTI:!UI::G AND THE FI?:AL SIZE OF THE FLOOL EVE!:T IS MOT EtiT2dELY CLEAR.
THE FOLLOWING CREST REPRESE;lT.;I::IF.UM GUARA!) TEES RATHER THA!: FItAL F IN AL FORECAST. THEY SHO'J SUST A:!T I AL FLOODI!:G THROUGHOUT ALL THE U:4 PROTECTED LOWLAt:05 THROUGH 50TH ST ATES.
l RIVER OR LOC FS OR 055 FORECAST FLOW IP:i CONNECTICUT RIV I:0NT A30E CITY 28 24.9 CRIST 33[34.FT 2/19 NORTH HA::PTO::
112
, CREST 116:117 FT 3/lA7.
HOLYOXE 9 5.3 CHEST 1p FT 3/lc SPRI:lGFIELL 20 11.6 CREST 17 FT 3/7AN HARTFORD 16 17.7 CREST 23 FT 3/7Pr.
THOMSONVILLE 16 9.9 CREST 14i15 FT 4/7AM w
IGi:1 IGNORE FLOOD STA3E AT TH0y.50!!VILLE IS VRION3 Ol THE NEXT MESSAGE 's'ILL cI ISSUE; ilEARIOP:; TONIGHT LL INTEREST ARE. URSED TO CHECX THIS y.ESSAGE SI;;CE FORECAST r.AY BE REVISED UPWARD AUTH HOFXINS
'S P
l'N:lN 4Hhs - L l
_ T P 9 E _ T. M [ ' 5 T
_,n.
a
ZCZC
.RJ3 RVRA 020244 ZZZZZ SULLETII E ATHER SERVICE RIVER F37.E':A3T CE::TER HARTF3RD CI
- i.,
21 44Ee THUACCAY -04/31/76 v
FL33D WAhNIN3 BULLETI:! F3R THE LCVER C3!:::ECTICUT RIVIR I!: ?. ASS ACHUSETTS A::0 C3:..r.CT ICUT.
f HEAVY RAIN IN ThE CT:NICTICUT RIVER d ASI!: H AS CUASIC SU53TA::TIAL RISES IN THE C3:.t.ICTICUT RIVER.
FL30 DIN 3 IS ::32 3CCURRIN3 I:. IdE UPPER CONNECTICUT RIVER A::D ALC*:3 433T OF THE L3YER CD::NECTICUT R IVER IN ?. ASSACHUSETT3 A::D CTl:'EOTICUT.
?;3;IRATI FLC3;IN3 ILL CONTINUE FOR THE :: EXT C3]PLE OF C AYS.
ALL INTEREST 3 ALT 3 T h E C ON::ECTICUT RIVIR SHOUL; SE 3:. THE ALERT FOR THE D.?ICTEL CREST 3.
F OLL3 VIN 3 ARE CAEST FOREC ASTS........
AT r.ONT A3UE CIT Y.: ASS THE 7 P?. ST A3E VAS 22.5 FT A?:0 IT VILL CREST bETWEEP: 33 A:.0 33 FT FRID AY ?.ORNIN3.
FLOS; 3TA3E IS 2E FT.
AT NORTdH Ar.FT3:: :. AS5 THE ::RE3T.'ILL BE NEAR 116 FT AIOUI FRICAY
?. ID:;IGHT A::0 FLCO:; ST A3E hERE 15 1IE FT.
AT HOLYO.<E EA3S THE CRIST WILL 2E BETWEE:: 9 ANL 13 FT A33'JT F RIC AY MIENIGHT.
FLO30 3T A3EIS 5 FT.
1 A'T SPRIN3FIEL': r. ASS THE 7 Pr. 31 A3E VAS 12. I FT A::D THE CRIST W ILL BE ::E Ah 17 FT SATUR, AY I'.0R!:I: 3.
FL330 STA3E I5 E3 FT.
~
AT TH3XPS3t;VILLE CT THE 7 P.1 ST A31 VA3 5.5 FT A::0 THE CREST VILL eE i:E AR a FT S AiUa! AY :.CR::I:::!;.
AT HARTFORD CT THE 7 P4 3T A3E V?s2 l'd.1 FT A::0 ILL CREST dIT UEE:: 03 A::D E4 FT SATURC AY EVE::I::G.
FLO::L STA3E 15 15 FT.
W AT 63CXIN Ft0C.< :: EAR ::ILOLETDW:: CT THE 7 F?. STA3E WAS 9.'s FT.
IT WILL CREST t: EAR 15 FEET I ARLY SU:: DAY ?.3R::IN3.
FLO3L STA3E HERE IS S FIET.
s AT SIF.Sd]RY CT DN IHE F ARAI:23TC:. RIVER THE E ??. STA'IE VAS 7.5 FT.
IT WILL CFiE.if EET?EET 11 A::D 1E FEET FRILAY AFTER::C3:;
F L33D ST A3E HERI 13 12 FT.
THE NEXT.'. ESSA 3E EILL cE 153UEL FRIDAY.;33.::I::3 AUTH HOP.<I:3
>>'.r4 36 4l4hH.
r YLJ es w *.
w l
.t
- 37. 37. 37 TOR CT P3 LICE ::ET20RX LI3SE::I::AT IGN S
PL3 RELAY TO SP HLf.S I'l.'!A CT i:0AA VEATHER SERVICE RIVEh FORECAST CEt:TER HARTFORC CT i
11-03EST FRICAY C4/02/75 FLOOD ST ATEME!!T FOR M AS3 AND C3N:lECTICUT THE CON!:ECTICUT h1VI?.13 3TILL RISI':C THR3UGOUT ITS INTIRE LINTH IN M ASS AN; CD':NECT ICUT.0t: THE LOER MERRIMACX THE RIVER VILL BARELY REACH ITS 52 TOOT FLOOD ST AGE AT LO'** ELL MIDEAY SATURL AY.THE MORT:ING ST AGE VA3 43.7 FT. AT LAVERE"CE WERE FLOOD STA3E IS 20 FT THE ST AGE THIS MOR!:ING VAS 15.4 FT. A CREST OF 19 TO 20 FT WILL OCCU'r M IDC AY S ATURD AY. HAVEdHILL WILL CRIST SADURDAY AFTTERNDON BELOV FLOOD STAGE.
SPECIFIC CREST FORICA3T FCR THE C3::NECTICUT ARE A3 FOLLOVS FLO3C 7AM CRIST FORECAST STAGE STAGE
~i CONNECTICUT RIVER MONT A3UE CIT Y 28 30.7 NEAR 32 FT AT MIDI IGHT OF FRICAY d
NORTHAMPTON 112 e ilEAR 115 FT MIDNIGHT OF THURSDAY HOLYOKE 9
8.4 9 TO 91/2 FT MIDNIGHT FRI:. AY SPRIN3 FIELD E0 14.3 15 TO 16 FT MIDDAY SATUhDAY HARTFonD 16 19.0 21 T3 27. FT. MIDNIGHT S ATURDAY THOMSONVILLE 6.3 7 TO E FT MILD AY S ATURDAY Jp-30DXIN R3C.{
E 10.2 13 TO 14 FT 5"':3 AY MOR'11NG l
THE NE7.T MESSAGE YILL cl ISSUED 3ATURDAY EORSING l
AUTH H3PXIN3 k
t h
k"D.
s NNNN b
CORR N0hTH HAMPTON CRIST NEAR 115 FT hIDNIGHT OF FRIDAY L--_
@ hb-3 m
- z
~..... ~..
w "Q76 NPN Q+q-ll.
j l
h l
'r t
.T tercVC AZ Zeilu f GildhLCP01WWWWW
- n;.i p j t
' k E'
ZCZC
,k'4)
.I l
(
RWUL RhR., c3]M L o
.4 A
l AUiii. WLs.a hcR Lt.F.t'ICL HIVa.R ruRLC,14 Cr.N a r.R H,.h a F UHU C k
y
,I 10 2tL14 E,.
UR.,.Y (4 /03/ 70 j
i F1.00u 1. a.. a t.'.t t. : F LR i., fi;,. Cli u t c. : a s. : t.t.
C LiiNs.C s IC ui Ab l O
- l
'a HL CC f Nr.C ICU. RIVcR CF:cC. I'E htW I; shc EPRIllG FIctu r.i.SE.ic h 0LL a i l
,.R L,. s.tla. sit. R IVr.R IE h0C F..LLI t.G istit. li 0F SPR II;G F It.Lb t.du 5.ILL i (
R Il l t.G IN CCofc.C.ICU..
i U N s iit i.tRR I./.C K RIVt.R shL CRct. IS Juts s.PPEGs.Clili.J LOVELL r.t.LL.
i J
CR t L I t.G t ilLR L L r i t.R a C Y. t. LLWc.LL as.S S.
. 111 5 6.C n N I.fl3 5 t,. /.d L l
h,. L 2 1. (* rEL..6u I. WILL CR.E. a b-..Y ELIJil.LY UtLOU I a :<
FLocu L.,'. ; t.
1 0F 52 FLEs.
L WR s. t.C L rerES. WILL Cht.!: s h!S e.F.ER t;uuN
(. LEO LLIultiLY oLLot: I n t.
i F1.C C.,
t.. G L GF 00 rLL.
N., it..VLFtii1LL allIE LVtNIt.G cLLG2 1s t 4
I FLLL L., t.i t.
OF l'.s, c. t...
ff
- FORLC.Inf rLR.. t. CLNI.t.C.ICb RIVcR s.Rt. s.C FLLLG*.;0
, R IVr.R s.No Luc FS 7, i ; -
F0Ft t.C,.E.
l l
,ll i.01... G UL C I. Y 2E St.5 F, LL eLLOL' PLGGu bii.3E Lt.a t OliORi.0W EFRItG ILLu 20 f t.G l LW bcs.R CA LE IICL YL I.c.
9 9.4 rs.LL bLLt.Y FLOOu S.s.J L Ls.1 E 10r.0hECW i
a a h0s.FEUI.VILLt.
74 NLY Nr., R CR LC.
H,.R. r Lit.,
it EI.t CR r.E a Nt.s.R 22 1/E. FLc.a
(,PR IL 4
'l
!!.i;.0 lba i
g BLuMIN ROCK 6
12.C CRES. la.O 14 FEL: siPRIL 4 I A.; f 0 li ra 4
thL t.LA.. i.e.EE,.GL VILL Bc. IE5ulu EUt.ui.Y r:0RNING N
,l s.Us h libPhl f;E g
1 1
.s.
f
.(
~
+
s s
e
--4lt,.
(
l
..A
\\
c
_z
..L.
W j
y NWUS HWHA 041402 h j NOAA WEATHER SERVICE RIVER FORECAST CENTER HARTFORD CT
,q lj h
.)
_09 02EST SUNDAY 04/04/76 l
L'
!i' i
i p-R IVER ST ATEME!!T FOR M ASS ACilU3ETT3 A?ID C0:lNECTICUT g'
y [
THE CAE3T ON THE MEtlRIM A':K RIVER 13 I:3 THE LOWELL HAVERHILL AND
.f'-
L A'dRE:!CE A.'1E A 0F P. A3SACHUSETTJ TOD AY A!!I' THE MLHRIt! AC.4 W ILL 6EGIN i r l
l, q
A SLOW FALL TONIG:IT.
I L
S f[
THE CJNNECTICUT HIVER IPI M ASSACHUJEf f) IS NOW FALLI!!G AND THE y
f
[.;'t CHESI IJ IN THE HARTF0nD MIDDLETOWN HE.1CH WHERE A VEttY JLOW FALL 3
i
.s. )
W ILL dEGIN TONIGHT.
l h
ST AGE 3 AND F0!iECA3T 3 ARE AS FOLLOYS
=
'E 1
P[-
[
J
~
RIVER 0; LOC FS OH OBS REMAR43 l Jf-FLOW 7AM p;
I clERRIMAC.< RIVER
['
!j
/
LOWELL 52 51.0 FALLING.iLOWLY FROM LOYELL i
TO MOUTil CONNECTICUT RIVER MONTAGUE CITY 28 29.5 WILL FALL DELOW FLOOD bY TOMORRO*i l
3 HOLY 0r(E 9
8.9 F ALLI!!G SPRIT!GFIELD 20 15.3 FALLI:13 I
(
5 HARTFORD 16 22.4 tIOW NEAR CRE9T WILL BEGirl M
SLOW FALL TD.'
NOW !! EAR CRi.jIGHTsf WILL BEGI f
.)
M DOL.<IN ROCK __
8 13.4 SLOW FALL TI!IGHT s
'i" THE NEXT MESSAGE WILL BE ISSUED MONDAY MORNING AUTH HOP.<IrlS a.
i
-...--~4 d
~
t tf.
~
n:
l h
/3,8N
/
RWRA 15 216
/
-HFD BULLETIN FLOOD ST ATEMENT FOR CONN HOUS ATONIC MERRIM ACK NATIONAL WEATHER SERVICE BLOOMFIELD CT
_916PM_ EST MON M AR 14 1977 THE CONNECTICUT AND HOUSATONIC RIVERS ARE NOW IN FLOOD THROUGHOUT MOST OF THE TWO STATE AREA. THE CONNECTICUT IS NOW NEAR CREST IN
' NORTHERN MASSACHASETTS. IT WILL BE CRESTING TUESDAY MORNING IN THE HOLYOKE SPRINGFIELD AREA LATE IN THE DAY IN HATFORD AND WEDNESDAY MORNING AT BODXIN ROCK NEAR MIDDLETOWN.
AN ADDITIONAL HALF TO 3/4 0F AN INCH OF RAIN IN THE HOUSATONIC BASIN WILL CAUSE THIS RIVER TO RISE SLIGHTLY HIGHER THAN PREVIOUSLY FORECAST.
THE RIVER WILL BE CRESTING IN BOTH CONNECTICUT AND MASS TUESDAY MO8NING AT LEVELS SLIGHTLY HIGHER THAN THOSE MEASURED AT 7 PA.
MINOR FLOODING W'ILL OCCUR ON THE CHARLES MERRIMACK AND NASHUA RIVEdS IN M ASSACHASETS. SPECIFIC STAGES AND CREST TIMES ARE LISTED BELOW.
RIVER OR LOC FS OR OBS FORECAST FLOW 7 PM CONNECTICUT RIV MONTAGUE CITY 28 32.9 NOW NEAR CREST LITTLE CHANGE NEXT 12 HHS pao SLOW FALL THEREAFTER NORTH HAMPTON 112 4t4.3 NOW NEAR CREST LITTLE CHANGE NEXT lE HRS SLOW FALL THEREAFTER HOLYOKE 9
CREST NEAR 9 TO 10 FT TUESDAY MORNIN3 l
SPRINGFIELD 20 14.8 CREST 15 TO 16 FT TUESDAY MORNING THOMPSONVILLE 6.8 CREST NEAR 7 1/2 FT TUESDAY MORNING
-HARTFORD 16 175 CREST NEAR 21 FT LATE TUESDAY EVENING 3
__,BODXIN ROCK 87.*O CREST NEAR 12 FT WEDNESDAY MOHNING RMINGTON RIVE SIMSBURY 12 11.1 CREST NEAR 12 FT TUESDAY MORNING j[7)HOOUSATONICRIV
>GT. BARRINGTON 9 9.8 CREST NEAR 10 TO 11 FT TUESDAY NOON GAYLORDSVILLE S 10.9-NOW NEAR CREST,LITTLE CHANGE NEXT 12 HRS STEAVENSON 12 11.5 NOW NEAR CREST LITTLE CHANGE NEXT 12 HRS NASHUA RIVER EAST PEPPERELL 8 8.8 CREST 11 70,12 FT TUESDAY EVENING MERRIMACK RIVER LOWELL 52 51.2 CREST 52 TO 53 FT TUESDAY EVENING LAWERENCE 20 CREST NEAR 20 TO 21 FT TUESDAY EVENING THE NEXT MESSA.GE WILL BE ISSUED TUESDAY MORNING M ARCH 15 AUTH HACXETT s//6/77 -i n..:
s..' CU 6.ta
..;3i... 31...
3i S
FOR CT POLICE NETWORK DISSEMINATION PLS RELAY TO SP HDQS IN MA CT RI BULLETIN FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND NATIONAL WEATHER SERVICE BLOOMFIELD CT 1022AM EST MON M AR 14 1977 FLOOD ST ATEMENT FOR SOUTHERN NEW ENGLAND.
HEAVY RAINFALL DURING THE PAST 24 HOURS HAS CAUSED LOWLAND FLOODING OF SM ALL STRE AMS AND BROOKS PARTICULARLY IN THE WESERN 8 HALF OF CONNECTICUT AND M ASSACHUSETTS.
THE SMALL STREAMS AND
. BR00XS WILL BE RETURNING TO THEIR BANXS LATER TODAY.
LARGER STREAMS WILL CONTINUE RISING WITH LOWLAND FLOODING ALONG THE h00SATONIC, CONNECTICUT AND CHARLES RIVERS.
FOLLOWING ARE FORECASTS FOR SOUTHERN NEW ENGLAND RIVERS.'........
HOUSATONIC RIVER
,,~.
1'.
GREAT BARRINGTON M ASS.. 7 AM STAGE 8.9 FT.
FLOOD STAGE 9 FT.
J.
' CREST 9 1/2 TO 10 FEET LATE TONIGHT.
~
GAYLORDSVILLE CONN. 7 AM STAGE 9.6 FT FLOOD STAGE B FT.
i Ik CREST NEAR 10 FEET EARLY THIS AFTERNDON.
STEVENSON CONN 7 AM ST AGE 11.2 FT.
FLOOD STAGE 12 FT.
CREST NEAR 12 FEET THIS AFTERNOON.
CHARLES RIVER AT CHARLES RIVER VILLAGE MASS.
7 AM STAGE 3.7 FT
~
FLOOD STAGE 4 FEET.
REACH NEAR BANKFULL THIS AFTERNDON AND LITTLE
. CHANGE FOR NEXT FEW DAYS.
\\
7 AM STAGE 28.9 FT.
FLOOD STAGE 28 FT.
CREST f.'MONTAGUE CITY MASS NEA 30 FEET THIS EVENING.
NORTHNAMPTON M ASS 7 AM STAGE 111 FT.
FLOOD STAGE 112 FT.
CREST NEAR 114 FEET TONIGHT.
HOLYOKE NASS 7 AM STAGE 7.4 FEET.
FLOOD STAGE 9 FEET.
CREST NEAR 9, FEET LATE TONIGHT.
SPRINGFIELD MASS.
FLOOD STAGE 20 FEET.
Li#nrer urAR 15 FEET. TUESDAY. MORNING.
3/n.h ? - 2,
FLOOD ST AGE 16 FLET.
II
';ARTFORD CONN.
7 AM STAGE 13.2 FT.
r#'WILL REACH NEAR FLOOD ST AGE THIS AFTERNDO
~
20 AND 21 FEET TUESDAY AFTERNOON.
f FLOOD ST AGE E l
7 AM STAGE 5.3 FEET.
f g BODXIN ROCX NEAR MIDDLETOWN CONN. REACHING FLOOD STAGE 1/2 8 FEET.
FEET WEDNESDAY MORNING.
8 AM STAGE 10.2 FEET.' FLOOD FARMINGTON RIVER AT SIMSBURY CONN.IT WILL REACH FL
(
STAGE 12 FEET.
CREST NEAR 13 1/2 FEET TUESDAY MORNING.
.. NASHUA RIVER AT EAST PEPPERELL MASS. CREST SLIGHTLY A l
FLOOD ST AGE 8 FEET.
MORNING.
, NERRIMACX RIVER CREST 7 AM STAGE 49 FEET.
FLOOD ST AGE 52 FEET.
LOWELL MASS.
NEAR FLOOD ST AGE TUESDAY MORNING.
(
CREST I
LAWRENCE,M ASS.
7 AM STAGE 16.7 FEET.
FLOOD STAGE 20 FEET.
l ;' NEAR FLOOD ST AGE TUESDAY MORNING.
OTHER MAJOR RIVERS OF SOUTHERN NEW ENGLAND W VITHIN BANX RISES.
THE NEXT MESSAGE WILL BE ISSUED THIS EVENING MON AUT,H HACXETT P
k e
Y l
M s.w..
3}n h7-3
ZC4C s
WRJS.:.VR A 150453
-hFD BULLETIN FLOOD ST ATE. MENT NATIONAL WEATHER SERVICE 3LOOdFIELC CT i
753PM EST TUE MAR 15 197_7 FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND dOST MAJOR RIVERS IN SOUTHERN NEW ENGLAhD'HAVE CRESTED OR ARE NOW NEAR CREST EXCEFT FOR THE LOWER CONNECTICUT RIVER IN CONNECTICUT WHICH WILL BE CRESTING WEDNESDAY.
LOWLAND FLOODING CONTINUES ALONG THE HOUSATONIC CONNECTICUT AND MERRIMAC.< RIVERS.
CREST' FORECASTS FOR THE LOWER CONNECTICUT RIVER.....
. HARTFORD CONN. 7PM STAGE 22.0 FT. FLOOD STAGE IS 16 FT. WILL CREST.4 EAR 2j[ 1/2, FEET WECNESDAY MORNING.
Jda>%sBODXIN ROCK NEAR MIDDLETOWN CONN. 7PM STAGE IS 11.5 FT. FLOOD
/' STAGE IS 8 FT. WILL CREST NEAR 13 1/2 FEET WEDNESDAY EVENING.
f THE CONNECTICUT RIVER HAS CRESTED THROUGHOUT M ASSACHUSEITS AND WILL BEGIN To FALL SLOWLY TONIGHT.
J[]
THE HOUSATONIS RIVER HAS CRESTED AT ALL POINIS AND WILL FALL SLOWLY TONIGHT.
THE CHARLES RIVER CONTINUES NEAR B ANXFULL.
THE MERRIM ACK RIVER HAS CRESTED. AT LOWELL' M ASS. THE 7PM STAGE WAS k
53.0 FEET. FLOOD STAGE IS 52 FEET.. THE RIVER WILL BEGIN TO FALL VERY SLOWLY THIS EVENING.
THE CONNECTICUT AND MERRIMACX RIVERS WILL BE SLOW TO FALL AFTER CRESTING DUE TO RELEASE 0F WATER FROM FLOOD CONTROL RESERVOIRS.
THE NEXT MESSAGE WILL BE ISSUED WEDNESDAY MORNING-AUTH HACKETT.
' NNNN e
ZCZC WRUS RWRA 151551 tHFD
~
FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND.
MOST MAJOR RIVERS IN SOUTHERN NEW ENGLAND ARE NOW NEAR CREST.
THE EXCEPTION IS THE LOWER CONNECTICUT RIVER IN CONNECT 0 CUT WHICH LOWLAND FLOODING CONTINUES
'WILL BE CRESTING DURING WEDNESDAY.
ALONG.THE HOUSATONIC< CONNECTICUT < N ASHUA< AND MERRIMACK RIVERS.
OTHER MA,9 R RIVERS IN 0
THE CHARLES RIVER CONTINUES NEAR B ANXFULL.
SOUTHERN NEW ENGLAND ARE WITHIN THEIR B ANKS.
THE CONNECTICUT AND MERRIMACK RIVERS WILL BE SLOW TO FALL AFTER THE CREST DUE TO RELEASE OF WATER FROM FLOOD CONTROL RESERVOIRS.
j FOLLOWI NG ARE FOREC ASTS.......
HOUSATONIC RIVER f urre sw t 7 REST B ARRINGTON MASS.
EE90 FT.
'-@N0W AT CREST AND WILL FALL BELOW FLOOD ST AGE WEDNESDAY EVEN
/
GAYLORDSVILLE CONN.
FLOOD ST AGE 8 FT.
3 (hg NOW NEAR CREST AND WILL FALL VERY SLOWLY TO BELOW FLOOD STAGE BY
_FRIDpY MORNING.
STEVENSON CONN.
FLOOD STAGE 12 FT.
NOW NEAR s/.
- CREST AND WILL FALL SLOWLY TO BELOW FLOOD ST AGE BY FRIDAY EVENING.
CONNECTICUT RIVER MONT AGUE CITY MASS.
FLOOD STAGE 28 FT.
NOW AT CREST AND WILL FALL SLOWLY NEXT 24 HOURS.
NORTHHAMPTON MASS.
FLOOD ST AGE 112 FT,_ NOW NEAR CREST OF !!6 FT.
WILL F ALL Sl_0ut_Y NFYT 9A HOURY%)pjijn 8 AM sT AGt. :r.:n Fi. {tOSk%CC '
NRCREST AND WILL BEGIN FALLING SLOWLY THIS AFTERNDON.
TsocaSTAbE T i I
~
J -
SPRINGFIELD MASS.
FLOOD ST AGE 20 FT.
NOW NEAR CREST AND WILL BEGIN F ALLING ELOWLY THIS AFTERNOON.
g HARTFORD CONN.
FLOOD STAGE 16 FT.
WILL p CREST NEAR 22 1/2 FT. WEDNESDA,Y MORNING.
a l a l 7 ? 'l L
V~
^
7 AM STAGE BODKIN ROCK NE AR MIDDLETOWN CONN.WILL CREST NEAR 1
"" W A S 9.5 F T.
FARMINGTON RIVER 7 AM STAGE 10.8 FT.
FLOOD ST AGE 12 FT.
WILL j
~SIMSBURY CONN CONTINUE FALLING SLOWLY NEXT 24 HOUP.S.
FLOOD ST AGE 4 FT.
CHARLES RIVER CHARLES RIVER VILL AGE MASS.
WILL CONTINMNUE NEAR B ANKFULL FOR NEXT 5 DAYS.
NASHUA RIVER 7 AM ST AGE 9.2 FT.
FLOOD ST AG E 8 FT.
NOW 3 EAST PEPPERELL MASS.'NEAR CREST ANLrBELOW FLOOD STAGE i,seske MERRIMAWK RIVER LOWELL MASS.
7 AM STAGE 52 9 FT.
FLOOD ST AGE 52 FT.
NOW NEAR CREST AND WILL BEGIN F.ALLING SLOWLY THIS AFTERNOON.
LAWRENCE MASS.
FLOOD STAGE 20 FT.
NOW WEAR CREST AND WILL BEGIN FALLING SLOWLY THIS AFTERNOON THE NEXT MESSAGE WILL BE ISSUED WEDNESDAY MORNING.
AUTH HACKETT 4
s.
O
~
NNNN n
m O
I 3)>&l17 - si
NNNN ZCZC WRUS RWR A 161641 tHFD BULLETIN FLOOD ST ATEMENT FOR EOUTHERN NEV ENGL AND NATIONAL WEATHER SER" ICE BLOOMFIELD CT
!!41 AM EST WED map 16 1977 '
THE MAJOR PIVERS IN SOUTHERN NE',' ENGL AND HAVE CRESTED EXCEPT FOR THE LOWER CONNECTICUT RIVER VHERE THE CREST VILL BE MOVING SO','THWr.oD THROUGH CON,NECTICUT TODAY. LOV LAND FLOODING CONTINiiES ALONG THE CONNECTICUT HOUSATONIC AND MERDIMaCv.
CREST FORECAFT FOR THE LOVER CCNNECTICUT RIVER...
.HARTORD CONNECTICUT FLOOD STAGF 16 FT 7 AM STAGE 22.9 FT.NOW
, 7 f AT CREST AND WILL FALL SLOWLY BEGINNNING EARLY THIS AFTERNDON AND WILL BE NEAR 21 FT AT 7AM ON THE 17 TH.
)$" BODXIN ROCK NE AR MIDDLETOWN CT FLOOD ET AqE 8 FT 10 AM ET AGE 13.3 F1
-t WILL CREST NE AP 14 FT TONIGHT AND ST ART FALLING TOM 0090V.
_THE CONNECTICUT RIVER CONTIt* TIES TO FALL ELOVLY THROICTOUT MAEE
/AT MONT AGUE CITY FLOOD ST AGE PR FT 7 AM ST AGE 28.1 FT SHOULD FALL
/ BELOW FLOOD STAGE THIS AFTERNOON.
~~
THE HOUSATONIC RIVER CONTINt'ES TO F ALL SLOWLY THR0! PHI 0t'T ITS LENTH.
IT WILL PETURN TO LESF THAN BANxFitt STAGES AT GREAT B ARRINGTON MAEE THIS EVENING AND AT G AYLORDSVILLE ANC STEVENFON CT FRIDAY MOP.NING j'
MARCH 18.
AT GREAT B ARRINGTON FLOOD STAGE 9 FT 7AM ETAGE 9.5 AT GAYLORDFVILLE FLOOD ETAGE 8 FT 7AM FTAGF 11 4 AT STEVENSON FLOOD STAGE 12FT 7AM ST AGE 14.0 THE CHARLES RIVER AT CH APLES RIVER VILL AGE MASS WILL CONTINUF NE AR BANXFULL FOR SEVERAL DAYS. FLOOD STAGE HERE IE 4 FT 7AM Sl' AGES IS 3.9 FT THE MERRIMACX RIVER CONTINUES TC FALL ELOVLY.THE 7 AM ETAGE AT LOVELL MASS WAS 52.3 FT FLOOD STAGE IE 52 FT.
THE 7AM STAGE AT L AVRENCE MASS WAC 21 1 FT FLOOD ST AGE IS 70 FT.THE RIVER WILL FALL BELOW FLOOD ST AGE BOTH LOCATIONS THIS EVENING.
THE NASHUA RIVER AT EAST PEPPERELL MASE WILL FALL ELOVLY BELOW
- FLOOD STAGE OF 8 FT SY THURSDAY MORNING MAR 17.7AM ST AGE WAS 9.1 FT THE NEXT MEESAGE WILL SE ISSUED WEDNESDAY EVENING MAR 16 AUTH HACXETT
~ ~ -
aMh?~4
' 38. 38. 38.f
\\
FOR CT POLICE NETWORK DISSEMINATION PLS RELAY TO SP HDQS IN MA RI
- BULLETIN
/
FLOOD STATEMENT NATIONAL WEATHER SERVICE BLOOMFIELD 'T llO4AM EST TUI FEB 24 1981 FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND RAINFALL AMOUNTS OVER
,i SOUTHERN NEW ENGLAND VARIED FROM ONE INCH TO ONE AND ONE HALF INCHES EXCEPT FOR EASTERN M ASSACHUSETTS WHERE LESSOR AMOUNTS WERE REPORTED.
MOST RIVERS AND STREAMS IN SOUTHERN NEW ENGLAND ARE SWOLLEN FROM THE RECENT RAINS.
IN SOME AREAS THEY ARE ALREADY OUT OF THEIR BANKS.
ADDITIONAL RAIN IS EXPECTED FOR AT LEAST THE NEXT 24 HOURS OVER NEW ENGLAND.
THIS WILL CAUSE FURTHER RISES ON ALL RIVERS AND STREAMS SOUTHERN NEW ENGLAND.
IN MODERATE FLOODING IS EXPECTED ON THE C0tTECTICUT RIVER IN M ASSACHUSETTS AND CONNECTICUT TONIGHT AND WEDNESDAY.
THE H3USATONIC RIVER IS RISING AND WILL RUN ABOUT TWO FEET ABOVE BANKFULL BY WEDNESDAY MORNING.
THE FARMINGTON RIVER WILL RISE TO BANKFULL BY WEDNESDAY MORNING THE BLACKSTONE AND SHETUCKET RIVERS WILL RISE BUT REMAIN WIT BANKS BY WEDNESDAY MORNING.
THE YANTIC RIVER WILL RISE TO SLIGHTLY ABOVE BANKFULL 3
THIS EVENING AND RUN ONE HALF TO ONE FOOT ABOVE BANKFULL DURING TONIGHT.
RIVER OR LOC FLOOD OBS FORECAST STAGE 7 AM CONNECTICUT RIV MONTAGUE CITY 28 23.7 RISE TO 33 FEET BY VEDNESDAY MORNING HOLYOKE 9 6.2 RISE TO BETWEEN 9 AND 9 1/2 FEET WEDNESDAY MORNING SPRINGFIELD 20 12.5 RISE TO BETWEEN 16 TO 17 FEET WEDNESDAY MORNING THOMPS3NVILLE 5.2 RISE TO NEAR 7 1/2 FEET BY WEDNESDAY MORNING HARTFORD 16 17.5 RISE TO NEAR 21 FEET WEDNESDAY MORNING gh BODKIN ROCK. 8 8.8
_ RISE TO NE AR 12 1/2 FEET WEDNESDAY MORNING HOUSATONIC RIVE GT. BARRINGTON 9 5.3 RISE TO NEAR 7 1/2 FEET BY WEDNESDAY MORNING l
GAYLORDSVILLE 8 8.0 RISE TO NEAR 9 1/2 FEET VEDNESDAY MORNING l
STEVENSON 12 13.0 RISE TO NEAR 14 1/2 FEET WrnMrgnAY,Mn9MTNC b
YENM M
}
h
1AM.11NGTON HIVE SI.1SBUR Y 12 7.8 RISE TO NEAR 12 FEET WEDNESDAY MORNING BLACKSTONE RIVE WOONSOCKET 9 4.5 RISE TO NEAR 7 1/2 FEET BY WEDNESDAY MORNING SHETUC.<ET RIVER
~
WILLIN ANTIC 13 6.4 RISE TO NEAR 9 FEET WEDNESDAY MORNING MERRIMACK RIVER LOWELL 52 48.9 RISE TO BETWEEN 50 AND $1 FEET BY WEDNESDAY MORNING THE NEXT MESSAGE WILL BE ISSUED WEDNESDAY MORNING.
CRAIG HUNTER s
NNNN
= - ~ - - - - -
k t.
e l
1 2/t71H -7.
n.
\\~=^ }
7g
.g j;r
.,j p
- 46... 76... 76 hf 0'k FOR CT POLICE NETWORK DISSEMINATION
~
d (
ki PLS RELAY TO SP HDQS IN MA CT RI eh I
hj 3
9t l
1 f
p
]*
b n,
b
(
2 ZTZC BOSFLSHFD l
tl i
.Y RWUS RWRA 250317
,(%
-BOSFLSHFD 1
6 D
8 FLOOD STATEMENT 1
C l
g 3 s
i NATIONAL WEATHER SERVICE BLOOMFIELD CT
- p
}
h 1017PM EST TUE FEB 24 1981 FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND.
t
~
0 I
s'I p'
a jll RAINFALL OVER SOUTHERN NEW ENGLAND SINCE THIS MORNING AVERAGED FROM j
'T ONLY ONE TENTH OF $N INCH IN WESTERN CONNECTICUT TO BETWEEN ONE HALF 1
d j INCH AND THREE QUARTERS OF AN INCH OVER THE REMAINDER OF THE THREE SOUTHERN STATES.
BETWEEN ONE HALF AND ONE INCH OF RAIN FELL THROUGH p
i j'
){
H y
THE CENTRAL CONNECTICUT VALLEY IN NEW HAMPSHIRE AND VERMONT.
l-MOST RIVERS AND STREAMS ARE SWOLLEN FROM THE RAINSTORM R UNOFF.
THE i
f SMALL STREAMS IN MOST OF SOUTHERN NEW ENGLAND ARE ABOUT AS HIGH AS i
'A THEY WILL GO AND WILL BEGIN RECEDING TONIGHT.
IN EASTERN SECTIONS OF
.$ l (s
MASSACHUSETTS WHERE SOME RAIN IS STILL FALLING MINOR OVERFLOWS MAY 1
- (
l y
OCCUR TONIGHT.
i Utf i
l x;
h
-yt ks{
l y
W'
~
I i
g q$
THECONNECTICUT RIVER IS NOW CRESTING IN NORTHERN MASSACHUSETTS AT i
, p>
g (*
LESS THAN ONE HALF FOOT OVER FLOOD STAGE.
THE CREST WILL OCCUR IN t
4 SPRINGFIELD AND NORTHERN CONNECTICUT WEDNESDAY MORNING AND MOVE TO
] L.
(
q f f HARTFORD AND SOUTH TO MIDDLETOWN DURING THE EVENING. LOWLAND FLOODING
(
1 i p
ISOCCURRING ALONG THE CONNECTICUT RIVER IN MASSACHUSETTS AND N
3 Q
H CONNECTICUT AND SHOULD CONTINUE FOR THE NEXT FEW DAYS.
I;
[
l 7
l) f)%
THE MERRIM ACK RIVER IN LOWELL AND LAWRENCE 'M ASSACHUSETTS WILL CREST 1
a 1
, EDNESDAY MORNING bel.0W FLOOD ST AGES.
W y
j
, g-
[<
%.y
r oG.u s.% es.<:.
s n..' Gu c..> l r an c t;.s.it....
,, ~.... -.
p l
.... so.
I h
I '
RIVER OR LOC FLOOD OBS FORECAST 3
- k y
f, STAGE 7PM i
h CONNECTICUT RIV g-y l
'h MONTAGUE CITY 28 28.3 NOW AT CREST.. FALLING TO NEAR 27 1/2 FEET
/
s,'
WEDNESDAY MORNING i
F y$
HOLYOKE 9 6.7 CREST 7 TO 7 1/2 FEET WEDNESDAY MORNING b
?'
SPRINGFIELD 20 13.0 CREST NEAR 14 FEET WEDNESDAY MORNING j.
L THOMPSONVILLE 5.4 CREST NEAR 6 FEET WEDNESDAY MORNING
?
] '
.C HARTFORD 16 18.3 CREST 19 1/2 TO 20 FEET WEDNESDAY EVENING
,p BODKIN ROCK 8 9.3 CREST NEAR 12 FEET LATE WEDNESDAY NIGHT
.T MERRIMACX RIVER q-M LOWELL 52 48.8 CREST 49 TO 49 t/2 FEET WEDNESDAY MORNING LAVERENCE 20 CREST 18 TO 18 1/2 FEET WEDNESDAY MORNING 4
'< t.
i
'I G
BLACKSTONE RIVE b
WOONSOCKET 95.I CREST NEAR 6 FEET WEDNESDAY MORNING SHETUCKET RIVER 3
l
/
WILLIMANTIC 13 7.6 CREST NEAR 9 FEET EARLY WEDNESDAY MORNING f
t '-'
FARMINGTON RIVE a
g SIMSBURY 12 10.0 CREST NEAR !! FEET WEDNESDAY AFTERNOON i
4 Np HOUSATONIC RIVE
.A GT. BARRINGTON 9 5.6 CREST EARLY WEDNESDAY MORNING NEAR 6 FEET
,l g
M.
GAYLORDSVILLE 87.9
'Pl N
CRESTED THIS EVENING NEAR 8 FEET NOW FALLING 1
E5-
, SLOWLY TO 7 TO 7 1/2 FEET WEDNESDAY MORNING STEVENSON 12 ! !. 7 CRESTED TODAY ABOUT I FOOT OVER FLOOD STAGE AND NOW FALLING SLOWLY TO 9 1/2 TO 10 FEET WEDNESDAY MORNING
.3 i
t,%
THE NEXT MESSAGE WILL BE ISSUED WEDNESDAY MORNING 7
,g CRAIG HUNTER I
';}
p
- a. Jg
$.4
, e N
N r.
l
.-).2 i
~
i d
I l-
- 1. 'i N
- 3
7 Y
k W 6 M M W.h M N
(
l i]
7 L,
~
.a.
4 7
=ty p ~..-~' ~
%.h ZCZC BOSFLSHFD WRUS RWRA 251648
-BOSFLSHFD
i
' BULLETIN t{,,
FLOOD STATEMENT
~
b' NATIONAL WEATHER. SERVICE BLOOMFIELD CT ll48 AM EST WED FEB 25 1981 FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND RAINFALL AMOUNTS OVER SOUTHERN NEW ENGLAND DURING THE LAST 24 HOURS VARIED FROM ONE HALF INCH IN WESTERN CONNECTICUT AND THE BERKSHIRES
...TO 1 TO.2 INCHES IN RHODE ISLAND AND EASTERN MASS.
GENERALLY SPEAKING..MOST STREAMS HAVE CRESTED OR WILL DO SO BY LATE TODAY.
A FEW LINGERING SHOWERS ARE FORECAST BUT THEY ARE NOT EXPECTED TO CAUSE MUCH EFFECT ON THE RIVERS AND STREAMS.
THE BLACKSTONE RIVER IS CRESTING NOW AT WOO.9 SOCKET..RI. AND WILL 3
CONTINUE A SLOW FALL FOR THE REST OF THE DAY.
THE SHETUCKET' RIVER IS ALSO CLOSE to CRESTING AT VILLIMANTIC..CT AND FALLING STAGES ARE EXPECTED TO FOLLOW SHORTLY.
THE FARMINGTON RIVER DID NOT GO QUITE SO HIGH AS LAST VEEKEND AND IS NOW SLOWLY FALLING ALONG ITS ENTIRE LENGTH.
t THE HOUSATONIC HAS CRESTED AT ALL POINTS AND WILL CONTINdE TO FALL SLOWLY FOR THE NEXT DAY OR S0.
- THE CREST ON THE CONNECTICUT RIVER FOR THIS STORM IS NOW IN THE
'r T HOLYOKE.. SPRINGFIELD AREA AND SHOULD REACH HARTFORD LATER TONIGHT.
THE MAXIMUM ST AGE AT BODKIN ROCK WILL OCCUR ON THURSDAY MORNING.
COLD VEATHER IN THE HEADVATERS WILL RETARD THE RUNOFF THEREBY REDUCING THE AMOUNT OF FLOW INTO THE RIVERS.. CAUSING THEM TO l
RECEDE AT A FASTER RATE THAN MIGHT BE EXPECTED.
2/27[7f d
n'1VER OR LOC FLOOD OBS FORECAST
^
STAGE 7 AM
- MERRIM ACK RIVER LOVELL 52 45.33 CREST BETWEEN 50.5 TO 51 FEET LATE TONIGHT
.LAVERENCE 20 16.7 CREST NEAR 15 FEET LATE TONIGHT BLACKSTONE RIVE NORTHBRIDGE 9 6.0 FALLING TO NEAR 5 FT BY THURSDAY AM
. OONSOCKET 9 6.2 NOW NEAR CREST
- FALLING TO 5 AND A HALF V
W i
THURS AM
~ SHETUCXET RIVER WILLIMANTIC 13 7.5 NOW NEAR CREST FALL TO 6 FT BY THURS AM FARMINGTON RIVE SIMSBURY 12 10.1 BEGINNING TO FALL REACHING 8 TO 9 FT THURS o
HOUSATONIC RIVE GT. BARRINGTON 95.6 FALLING TO NEAR 5 FT BY THURS AM GAYLORDSVILLE 8
7.7 FALLING TO 6 AND A HALF FT BY THURS AM STEVENSON 12 10.4 FALLING TO 8 AND A HALF TO 9 FT BY THURS AM CONNECTICUT RIV MONTAGUE CITY 28 28.1 FALLING TO BETWEEN 26 AND A HALF TO 27 FT BY THURS AM NORTH HAMPTON 112 113 NOW AT CREST FALL TO NEAR 112 FT BY THURS AM HOLYOKE 9 7.4 FALLING TO NEAR 6 AND A HAtF FT BY THURS AM SPRINGFIELD 20 14.9 FALLING TO 14 TO 14 AND A HALF FT BY THURS AM THOMPSONVILLE 6.1 NOW AT CREST WILL FALL TO NEAR 5 AN A HALF FT THURS AM HARTFORD 16 19.3 WILL CREST LATE TONIGHT AT 20 TO 20 AND A HALF FEET BODXIN ROCK
- 8 9.8 VILL CREST NEAR 11 FT EARLY THURS AM SOS THE NEXT MESSAGE WILL BE ISSUED THIS EVENING BRUCE WHYTE k
~. %
~.r,- - ~ - q"
.,,-r~--
~
I 1
,- A
. W M Q%2g:
ws,
ww-mm upF
_w_ r l
2.)z,Ill - 6 o
wgvw w 24A N 'e%bM@
l
$Y$
~k ik*l $l. h.$ i 4.V. ~';
,.$$h Y
5 "-
Q ,,.
3,,,tff y. d.- :-l. ',y '*(.. lf '
.1,1 *
- ',.. 4f NjNDG,AED.' W{'.'..,.. A
- ~*
7 c
_,w.a",.-
d
.IEL t
~R/US'$ SFLSHFDRWRA ggo35c % m.'T Wh'.";
~
.ZCZC g
)l
., tF0 FFLsHyp, j
FLOOD STATEt1ENT 0.W Ln CT 155 F T 'J p r
p 3
- l 4,
i TLCOD FTtTE."E"T FOR ' OUTHER!' NEk' E'!OLAND S
A f*IXTURE OF FrIF t.ND FNOW FELL OVER FOUT'HER'? t'E':' drCLorr TO D AY.
IP THE C0t'NFCTICI)7 VALL'EY LI OUID. PECI.DI Tt.TI'"'
r*""*"**~"'"
o y
. ej TtNCED TPOM t TR ACE t!EAP. THE.CO AFT To t:EAPLY O!!r I"C" I Jt'w!"
4 Mt.0F ACHUFETTS.
TIVE INCHES OF HE'3 e N0 YA F. REP 0 "TF" P"' A P t."""!*L" f9 MfSSPCHUTETTF.
Et.STES.t! Mt.rS tCF;L'.EETTP REC'EIOED LIOUID PEEC IPITATIb' 'O'al" "'/"G"."
FRO. t! EAR O'!r F Atr It'CH Ill 'INTERIO" L0ct,TIOPc TO Or" t"r / 0"""*
[
IflCHES fEAP THE COAST.
SN0'l ACCU'!ULATIO!!c OF PeteLY le I':C""~"~~"
E EPO P.TED.
s.
4
[f EteTER" C0?!MECTICUT ANP P.HODE IFLArt GE.NEPALLY DTC7I'/r*
g i' LEEF T5'.Y1 0"E Ft,Lv ITCH OF LI1CI.* oFTCI?ITATID':.
}Y i
7, THE ADDITIO!'AL ??.ECIPITt.TIO*3 MAF C AUSET SOPT OF THr FI'!~?" T' i
f, C0!'TIP'UE TO RISE AND DELAY THE CRESTF.
fp' i
~
r,.
~
if THF HOUCAT0"IC PluEp 'ATEPSHED At:D THE FAE"IPCTC" EIVER '.'A7rerf t" l
'd' EECEIVED LITTLr ADDITICUAL PRECIPITt.TIO!!. THESE EIVERT YILL
{ C0"TI!!UE TO FtLL CLO'!LY FOR THE NEXT set'Er AL payr. 2)n }fi- ?
-.-s......... LC*a? 0yet*~ 4. ,"7,,. . 7 p. -.,, T. IV Er,- L? r. o . g g,,,
- i'.' l*E*RI:" ACK PI V7"
.:V e I.TI"C m Lv TU"r**tY *ttfD *O 1/0 Tr*T, e a ?s < LO'.'"1.L 5",.a ..-.e 1 -.,. i...- e r...,. -..,e. r nr 1.. a t y re r...r.,.- 4 w f c JJti'. PL ACEFTCf'E R:VF .NORTHeRIDGE 9i Pe AP CeEcT. TALLI"G TO **rt,P 5 1/2 Frey ,4 'Q.' TF"ceDAY '00"IN7 =V '/00.!!c0CMET 9 S.5 K 1/2 TO 7 "EET eY TEUntrtY ?V F!11?'O ~;4.: .. D:SHETL'CMET *IV"" .'d-3' WILLIMe" TIC 13 2 "~ re T Tit T." eTTT T"UP"I t.Y !!T!'IO
- W.%
- 'f C0!::'ECTICUT eIV
.'3. i.MONT4?t'E CITY O 23.5 ?' ~ t " 30 FEI'T Et eLY THt!Eer AY' !"0FN'1"r . F;, -i !!2 7 !!! 1/2 TC l i t. rEET T5iUFertY !'OTNI!!G '?, P '
- ! ORTH NteTO"
'.*a'. FCLYOME D? E TO E 1/9. FFET Tu'trer. AY ArTTRr00!' SPPINGFirLa 20 15.4 CeEFT !'Ef.E 15 1/2 TECT T!!UPett,Y FOR'11!!C 4- Sy lgN.4THOMPe0NVILLT. 5,4. CRECT TRURePe.Y Y.ORNI!!G NEAR;7 FEET M[ s Y 20.1 TURE7?OREt." 9.2 rEET Tugeeppy gogg7;i-3 DOCv c 10,4 Cc"c7 nit.P. !! 1/2 FEIT LATE TuUPePt.Y NICP.T g".. 20 Mi r .W ' EDUeATO?!IC *IUr ~' 3" ' GT. F tecI ?'* T0" 9 5.7-r a,LLIt:0 etC'.'LY 4.7 .Gt.YLORD.VILLT 8' 7.4 Ft.LLI?!? "LC"LY c T-
- STEVEN.eCN 12 10.3 FALLIt:G SLD5'LY. -
k .. t ~,. THE'WEY.T MEeF AGE WILL.EE ISSUED THURSDt.Y 110Rf11NG . s. b 'p.WAYfl{ SMITH l e [
- $, +,
[ = ~ ~ i g
- r,
.,k g* {,,",*)_P;'/K.3 ; 4 .e l
. '..W...;:. .j. NNNN.".G j,.;, ..s.r.,;.g m ., A.4~r g. 4' -7 : M $ ' (' K. 3 7.... 3 7 7. 4. f. . i. -; FOR CT POLICE NETWORK DISSEMINATION g g, PLS. RELAY TO SP HDOS,IN MA CT RI' ,.? ' I' ,.. J,, Jg ,. ;,.' k l.k i ..,...sq ZCZC;B0SFLSMFD WRUS RWRA 261622
- f
."M; g -80SFLSHFD i l'4ZZZZZ ' ;f.i,. . v. ?" BULLETIN ... m* ,{9 r. FLOOD ' ADVISORY r ~. '. ?:: '4 ?.. NATIONAL WEATHER SERVICE BLOOMFIELD CT-g N.G.W ^ .. ;7.' $' - 'A 1122AM EST THU FEB 26 1981 kN .*C t- [*.Q;' .// h.~ .Q.* '.Y ., C ' x.. g?*g..[ FLOOD ADVISORY FOR SOUTHERN NEW ENGLAND i s n. $..C i . M' " %. 'ANOTHER., STORM IMPULSE MOVED ACROSS NEW E ' (. ~'.~. '. v 9 IADDITIONAL RAIN AND SNOW. OVER CONNECTICUT RAINFALL AVERAGED FROM '@. c'.'S~. NEAR2 NORTHERN SECTIONS. THE NORTHWEST. SECTIONS HAD 8 INCHES.0F SNOW ih ONE QUARTER INCH ALONG THE COAST TO THREE QUARTERS INCH IN..~, ,;$.',. REPORTED. ' i IN MASSACHUSETTS THE TOTAL PRECIPITATION RANGED 97' INCH OVER WESTERN SECTIONS TO MORE THAN 2 AND A HAL -t FROM 1 j '}:. COAST. SNOW WAS REPORTED IN EASTERN AND NORTHERN MASSACHUSETTS. ? '7 RHODE ISLAND HAD MOSTLY. RAIN.. RANGING FROM ONE H '. T y n ~ -h '#!' RIVERS AND STREAMS IN SOUTHERN NEW ENGL ,,.e: 'THIS THIS LATEST RUNOFF. IH ADDITION..THE CORPS OF ~ T O ' 4' ' .D r PROTECTIVE AREAS. CONTROL DAMS ARE RELEASING WAT ENGIHEERS FLOOD in ~D. ". ?,,,
- c. -
I' ...i-2.* THE CONNECTICUT RIVER WILL CREST THIS AFTERNOON IN ] .y .(9"' AND ' CREST IN SOUTHERN M ASS AND NORTHERN CONN LATE T NORTHERN MASS.. .E' .'. ABOUT. A TO 5 FEET ABOVE FLOOD ST AGES. RUNNING ..s
- f.
- TO HARTFORD AND MIDDLETOWN DURING FRIDAY.. RUNNING
f, FLOOD STAGES. MODERATE FLOODING IS EXPECTED ALONG. THE CONNECTICUT N' RIVER. ALL CITIES WITH DIXING SYSTEMS WILL BE PROTECTED. O...... THE CHARLES ' RIVER IS RISING TO ABOUT 1 FOOT ABOVE FRIDAY MORNING. FLOOD STAGE BY THE NASHUA FRIDAY MORNING CAUSING LOWLAND FLOODING. RIVER IN n:. 12 FEET i ) b!~ -y-.,_. - -,. -. _ - - -,. - -,.... -, _. .,m,. ...-,.-,.,--.m- -. -. -,. - -.. -. -....,,,.. - -, -, -. -, ~. -., - - .--e
i. 1 .I e.. THE. MERRINACK RIVER IN M ASS..WILL BE CRESTING LATE TONIGHT ABOUT ~, ' ' 4,?e FOOT ABOVE FLOOD ST AGES WITH LOWLAND FLOODING EXPECTED. r r g. THE NEPONSET RIVER WILL CREST TONIGHT NEAR 'OR SLIGHTLY BELOW ' BANKFULL. q. HOUSATONIC l ht THE' SHETUCKET...F ARMIhGTON...CHICOPEE...BLACKSTONE... A 1 RIVERS ARE EXPECTED TO CREST BELOW BANKFULL. 'r,. y., \\ h,r' ..5 At.f FOLLOWING ARE CREST OR STAGE FORECASTS.... NI'VEiiON. LOC FLOOD 0BS FORECAST ' ~ ' , (d gh STAGE 7AM ./ ?'y0NNECTICUT RIV V MONTAGUE CITY 28 29.3 CREST 32 TO 33 FEET THIS AFTERNOON ~j: NORTH HAMPTON 112 114.2 CREST 116 TO 117 FEET TOWARD THIS EVENING ~ HOLYOKE 9 7.9 CREST 8 1/2 TO 9 FEET LATE TONIGHI .;4,*e SPRINGFIELD 20 16.1 CREST 17 TO 17 1/2 FEET LATE TONIGHT - .;9 i 4 Q,THOMPSONVILLE 6.8 CREST NEAR 7 1/2 FEET LATE TONIGHT,. / 4,T 4 ,q. HARTFORD 16 21.0 CREST 23 TO 24 FEET FRIDAY MORNING 't. .*.BODXIN ROCX 8 11.~3 CREST 15 TO 15 ' 1/2 FEET DURING FRIDAY ~ c i .,!, CHARLES RIVER I 'Sc-DOVER 4 3.2 RISING TO A LITTLE OVER 5 FEET FRIDAY MORNING i ' T1tKSNun navt.K ' ~ ~ ~ '. ' EAST PEPPERELL 8 6.0 RISING TO NEAR 12 FEET BY FRIDAY MORNING lf ~ '. ' " '.. TE ' gg \\ Cl-MAYNARD 5 4.2 CREST 5 TO 5 1/2 FEET FRIDAY EVENING. U r. g. ~ h MERRIMACK RIVER t/ LOWELL 52 50.7 CREST NEAR 53 FEET LATE TONIGHT O' r,'J. : LAWERENCE 20 18.6 CREST NEAR 21 FEET LATE ' TONIGHT
- x.
- 15 NEPONSET RIVER
. ',,,.g. NORWOOD 9 6.0 RISING TO A CREST OF 8. TO 8 1/2 FEET TONIGHT, [,- .e BLACKSTONE RIVE "E ~ .NORTHBRIDGE 9 6.1' RISING TO A CREST OF 7 TO 7 1/2. FEET THIS 'J : AFTERNOON AND EVENING d.j 'WOONSOCKET 6 6.6
- RISING TO A CREST OF 5 TO 8 1/2 FEET EARLY c-FRIDAY, MORN,1NG l
- SHETUCKET RIVER l
WILLIMANTIC 13 7.3 RISING TO A CREST OF NEAR 8 1/2 TEET FRIDAY, 7 1: ' & J-MORNING ,t l
- CHICOPEE RIVER INDIAN ORCHARD 12 7.6 CREST 9'TO P 1/2 FEET LATE TONIGHT.
' !1
- FARAINGTON RIVE
.SIMSBURY 12 8.1 CREST 9 1/2 TO-10 FEET FRIDAY (400N,
- '4 R
HOUSATONIC RIVE .' N j.),.GT. BARRINGTON 95.6 RISING TO A CREST OF 6 TO 6 1/2 FEET FRIDAY C* MORNING. ,Q , GAYLORDSVILLE 8 7.3 SLOW FALLL TO NEAR 6' 1/2 FEET FRIDAY. 4 /* - . MORNING
- .I xv.N ;. y STEVENSON 12 10.3 SLOW FALL TO NEAR 10 FEET FRIDAY MORNING, 5
..-. m , s.e w e et ys e7: - --- t: L. W..:,n_ "=. t 7. "-- =" vs..- 1_v ries _~. ~. - m ,1012?M ~ ErT T:*r "- e.: 15 ! '.7.i ; .. *j f.. ~.bFLOOD ST ATEME"T FDE.COUT' ER!! r!P E!!? Lt.l!D. ~ 3.+ b! TkE ' rut"0Fr cr'0" 9'!O" I" THE rT"T?t t '"9' 00 *T"r.'" ?r""CTIC"? I"cr * .,/ B A*II: ' I.c
- EI"O R*:Tt "" E" "Y TE: ?"
'T"??" I" T- "I"TLr frp t.c" ,$.jTHIRTIEc THIc PU::cre FLUc "t.TE" -"I"e ErLEteer "T0" FL0or C0"TFDL ~ V D A!ic. 0!).Tu! C3"!:rCTI CL'T PIVER Tel.'! *'.I *c tJ".T""? It'0 TO ucLp Tyr ,Q.'$ ENTIRE r.EACH Or THE C0!'rECTICL'T EIVTT ' E0 !* "DETurng y g e r t C Ht'e E T T P '. i_INTO 'CO NFEC TI C'.' T t.T AL!CeT eTATICrf.PY HrIr.'Te. TFr CpreT Ie OCCURRI ?.e, I!: CD'?"ECTICUT Not' TPROUGH THE rIGHTTIt'E FOURe AT t0UT e { s, 1/2..TO 5 FEET t.80VE FlopD eTAGEF. LO Lot'D FLOOPI"4 Ic C0' TON t't.!tM .d .. ME CO'INECTICUT PIvr2 TFROUOR MAcrACHl'SETTS f rD CottrirCT.ICUT t"0 VILL &+ CONTINUT. FOR Tur rgy.T *EVFRAL DAYS. ~ 4 .g+!THEMEroIyerv 91Vrn.'ILL 'E C"ESTI"r Lt.TF 70!:IOPT I" Facer.CHUrerTe .J y, MAR.EL000 eT/"-EC "ITH LITTLE CH AFnE TXPEC'TED U"TIL FRIrfY FORT:IPC. jff 1.6 2t 1 s yTHE _jCHAMLFS RIVER I'f ::A?CACHUCETTE YILL CP.EeT APOUT ONF' FOOT / PONE -gop,D/. STAGE ArD -REMAIN AT THAT LEVEL OVER THE tfFrgy;;p. ,, f,f-gg. Qi.a * - .: p
- c.'l QWTHE' FlerXeT0"r PIVER It:: rrec3CHucETTc t"P "90rE -IettrD IS' t'Ch' t:rt.F
.nq CREST *ELc" otavrett par.'ILL eLot.:LY' Ft.LL FRIDt.Y ..f :. ,w Qf7HE '!r eHU e. FIVE2 IN *:teeACHUSETTc ILL RNACH. 'ATMFULL Y .F PIP AY. ~ '::* MOR.UI t:0. y Qg-C.. .,7 TMF HOUS ATO'lIC. PIVEP.,Ie t'ITHIt! ITS 9"Me ArD ILL C0!: Tit?UE TO FtLL '
- k. :V.SLOVLY.,
<a 5 g}. - 'THE F A*"I!'C-TO': RIurn ILL RE::eIn i.'"LL '.'ITHIf? ITC 96"Ye. i FOLLO','I' G t?E CFre T t."D S T A2 F. TC EEc t eT r........
- D
~+ ..i,l l ~ I N ftIVER OR LOC 'LCOD CT" r0?!CAe7 r:4. F Tt4G F 7 P ' es k k...C0t!':ECTIC"i nIn f':0NTrGUE CITY 2" 29.1 rr" ate " fe y re T 7ur.!! TONIGHT. "LC'.' rt.LL N .g, e ;I"" Ire pIpr.v p n!"e, ,g %s... OP.TM MAMPTor 312 "ec tr;:t.I" "rt ' 114 ---v Ta?'.' TorICr*. etce rt.LL "T93f".T" r?IrAv "Or"Irt.,....
~~ '? 7.S Pr. M t. I!1 TETY,EE!!,7 1/2 TO S FEET T!iPU 70 HIGHT. N ~
- f a d '.
HOLYOYE : t,. ' A ' ' cLO" et.LL.oEGIP.'!;!!:G r9I0tiY JtCcMIt'0 :. ,..,Yf.4..Pf.I!iG'3I ELD ~. '2.0 tie G cEXAII: E t D 15 erET.TMrU TONIGFT. CLdv EALL '.
- e. r_ I e., I,.c..
5 r g. r n I n. e s. ,,, - ** *. e e.., N' T 'I " ' " ' I TUO MP.e0!' VILL".- (.? r C -" 'l/' TO T' * " 'r::'.I.".I. L,_ --n z.'n: z e 7 p 3,.;;. :r.w" "I v c._ ..,,, s m -~- hphUf P h e.'T r0"9 ! ! . l. ' 0 T.*! "T* ?R "i T L*TE T0"TP:'T .. I' .g.ic ' '0DKIt! ROC
- 5' 12.1
': M c T t' ? ' " ! ? I /' ".F "U PI'30 T'l- "IC"I.
- hERRIM.9CV'AIS.
1 .'l [...*
- C'?TLL 5? 51.4 C7ETT
?'-'" ?? r TT Lt.TF TM'IGuT ",i PE!!CE 90 !",.4 C" ret "Ctr 20 FEET. LAT-T0t'IG"T ...a. a. I 4, w .: v CMA*:L ? *I 'r--
- j pov n a y,.,
c 7c7 e-.- -- T "" * *. ! T 't Y. * " P T -"
- I " ~
r aren =; - - T. v. r.:" T " " '.'ir v. ~ " ' \\.- -r yf.'PLtCreT0ahp!"r d T. !?C PTHe r.I M r & !.5 t'0" ti r." ".~~FT. L'ILL Ft LL 70 PrA P. S FEFT DY F9IDAY I:OPf It'G. k'CC t!':0 CKET ? 5.8 ??O" !!Eap CREeT. YILL FALL' TO NEAR,6 FEET PY t. F.*IDAY MORflING. !? ACHU2. T'IVEP EAST PEPPEPELL
- 7.1
? ICING TO " EAR cAFKFULL ny rpIppy t o pt;Ing, ,e ,Y'/. HOUS AT0f'IC pit'E ">T. ? t.P"I t!G TC'! 9 5.5 LITTLE Cuf agr ovgo. Iguy, etoy rf tt eEGIttt'INC [ji3 GA.YLO"P*VILLE ?. 7.? 'FtLL TO " EAR S.1/P. FEET ev FPIDAY "C FP'It'C. / FDIDt.Y !*0P91r0 y. ".. - STEVET 0" 12:10.0 e4LL TO l' EAR D 1/2 FFFT "Y FEIPtY "0Ft:It'G.1 ( F.tPMINGT:'" eI"r g l .A CI.".FD'.Y lt 7.R RT.AI!! ?!"AP 7 1/2 FEr.T OVEPt:IGHT. PLOY Ft LL r #I Dt.Y :*.0 5F It!G. ~. - i o s ,g TWEi"?v7 recaer VILL pE Icecra epipf,y ron: I sc i +7 D AV E.C'.'o T l c t.n l f;
- F.
R }4 '?l 21 -- 12. -
- ~
. pt. s... eg t i i l
..e c.
- 7....,_..,.,. - - - - -.... -...... -. -..
j-er ;- -: -jg .p.ma- ." T e T. *-. *.". - ' ' - ' - - - ~ ~ " ' 7 7 .e .Lww. T. u r F. ai r " ~ a v T. > ". ?*11T."O -' * * * * * * -* c "f" " * " A f * " f' ! " ' ? - - ' - . ~ fe- " - e i s. ~.
- r,=. r. n e - v a-.
vs T. r-e :* v --m'* t ' -' - 7, - * ~'vwur+~~ T. u. ' ;
- -"*e,
= =. = -.
- a n v.
.A j f a: c,,- - - *. g g a-a t a " '- a f ^ r ** 'tT' s'. j- .-{t ,.c r.e. y e c.: i y na e t a..' ". T. v t. e --.-"ma* e-~~~~
- l i r - ~ ~ p*
e t s.e- "..; a. y..1 . m e.e e " c. .ae**"e .p.-.. e..a e - m.g - L L 3.
- .e
..i.'., gg.. y y... 7 ..,.e...,, 3 *. - 7. e.. ... p. p.,. g ; q. - - -. v r= b.. s s. .e 7 og e4m g
- o g-e.., e p* g g v f g m.* e
- t g;
~ e C" ""..?C '. I ". " T. c.'.'."-- 7"? T. * ' r. "-"?. t r. e r ' e' ",a v ". ~ T . r*. c. * ?..'. re ?, i:r. " "ovru
- t. e.-
e, m... - v. e r t-tiyi L r.e c a u e t.c. ' " " T '. ~ r. e.t.T H. e ". > v a'."'.****
- r*
" T. 5 L e. s '. I ".. ". r n
- c 2
I 5 . Tu; v ?-T"aa* -'t'*? T-PT C"r*T $7 f '"'" I'L L e
- ara I t' '
ar f, e e.., p f.,. -
- 7. e
,n- , 7. - i - eyfe-- g- -"; -a 7 - p t.S t.* e v t. - s'e s
- n,a i.. a,
- i e
'.'r.'.' r {Q " rg
- g e.. -
7 ~2.
- r..g l'
..a*--* !* ) M M. *.* es e.x.) T y n. f g Y.a. ag rw e
- .LL O T".? >
t'-*' L . " r. e ?. ? r "e 7" e" '.t + u. e a.
- a..r. ". r"at,"-
"'r I i e -"t.i l. i r.e. e e.. ; a r s. .A D.e 'l.r.1 0 ". C a n v. rpt 1_
- , e n. ".f t.1.
- r Dr.Cr*,PC P. U Q.T "-
T. U. " T. V T.. ^. 4 ".* H ?. e. .t. ' ?. C L L*a ",' "a a-- ?".. .c - ~. ~ ~:. I -., -.. "'. C.* *....... ~ s .f TIUT* CP LCC. "LC :- 0-* -*) i re! c '. ) e7.:e,,.- (* A C.,..o r.. I., / "0"T rr*'r e ;;v <> /r e?T o T"F r.".v av
- 2. '7
.r e. Li,,I r e T? "ra-
- *P - " P * ?
i t'O P.;u n 3."..... - .r e : r - gjo -.ttier 7 -i.,. La.,, La g e, e v e.- r 73 I f- +- co e n,, 3 n .,,v...,. ..c-.-. e v., Fr v "r. e-'gr i # m c.or.vaery - e. i.,, nr.n,, n erw. 4
- **% m sg I.I..r.
,3
- 2. -, -
Tu..g vp e. s-...,. L.. e. c. ,:. rT..e r o i;. e. . 1/t. ,, c r.-. ,p-eev. c -. t r. uppTeg-- 3,c3,- n;" f,7 p. ze T "I LL " f. LI' T*' ?C TO ' ' 1/.*'. ' r" F T 4 ., i ". r.i n v. a. e.n t. r e / k T0*"I" ? C" 12.- "" *~ r-~~T e,,'peo.v'. !*,Lr LL *: *TTt'*r" 11 1/? 39 r ;-. -
- s.., f.c. r. p.
-a
- v. C Y..*
.t. e - I u - ~- w 707L' bon c'a-r pv.. - s.. , Tuppp.v rOpelet .), ac TIae-- Lo.. n:e-(Y ,,3.. s,,. ,,,,..c- .g e-- y%, - a. " .n.g-- c-.- ,,. v9 pee i 1 ._.n..i....., t~m. .:.... e - T...- - -.. i, v.., r..... - - -,.. ~. s., ,,,,a.... v,n ...f r,,-- 7 e, 7,,": -. v - nyr, ,g . :v. g,,s.r e ng.,.i. n. y.3 . '4 '. T' " rM *"- .~..~s".". ,i. 4.. . s + e 4 1/o c - r e - c.., n, v. t.t I " c ". -. *t '." e " .,ya
[ggfpg h h BOSFLWHFD WOUS00 KHF0 141800 BULLETIN ().
- FLOOD WARNING
'.N AT I O WEATHER SERVICE RIVER FpREC AST CENTER, HARTFORD. CT (LUtd) o 12:00 JEST UEC 14 1983 (3 o n T. FLd3D WARNING FOR SOUTHERN NEW ENGLAND ()
- THE N ATION AL WE ATHER SERVICE HAS ISSUED A FLOOD WARNING FOR f t*C CONNECTICUT RIVER IN MAS $ACHUSLTTS AND CONNECTICUT ANU THE N ASHU A RIVER AT EAST PEPPERELL MASSACHUSETTS....
A FLOOD WARNING REMAINS IN EFFECT FOR THE HOUSATONIC RIVER IN CONNECTICUT. THE CONNECTICUT RIVER IS kISING R APIDLY IN MASSACHUSETTS AND CONNECTICUT. MIh0R FLOODING CAN BE EXPECTED ALONG UNPROTECTED AGFA3 () 0F THE RIVER FOR THE NEXT FEW DAYS. MINOR FLOODING CAN ALSO UE EkFECTEU ALONG THE H3USATONIC RIVER IN CONNECTICUT THROUGH THURSDAY MORN!fdG. () ELSEWHERE.IN SOUTHERN NEW ENGLAND THE RIVERS WILL RISE BUT RE"AIN WITHIN THEIR BANKS. (/ CONNECTICUT HIVER MONTAGUE CITY..MA FLOOD STAGE IS 28 FEET. 7 AM. ST AGF WAS 04 7 FT RISE TO 29 1/ 2 F T T O 3 0 1/ 2 F T bY THURSDAY Ml0RNIN G..L11TLE CH ANGE () DURING THE DAY THUR$ DAY. NORTHAMPTON..MA FLOOD STAGE IS 112 FEET. 7AM STAGE WAi MSG (s CREST TO NEAR 113 1/2 FT BY THURSDAY MORNING. HOLY 0KE..MA FLOOD STAGE !$ 9 FEET. 7AM STAGE WAS PSG - ()% RISE TO BETWEEN 9 AND 9 1/2 FT BY THURSDAY AFTEkN00N. SPRINGFIELD..MA FLOOD STAGE IS 20 FEET. 7 AM ST AG'E WAS 10.3 F T (> CREST BETWEEN 15 TO 15 1/2 FT LATE THURSDAY MORNING. THOMPSONVILLE..CT 7AM STAGE WAS ?.. n IT A() CREST NEAR 6 FT BY THURSDAY MORNING. g dk P HARTFORD..CT FLOOD STAGE IS 16 FEET. 7 AM ST AGE LAS 11.7 FT (s l REACH FLOOD STAGE WEONESDAY EVENING.. CREST TO NEAR 20 1/? FT / FRIDAY. sem (d MIDDLETOWN..CT FLOOD STAGF. IS 8 FECT. 7AM ST AGE JAS 4.0 F T RISE TO NEAR 8ANKFULL CARLY THURSDAY MORNIN3. () MERRIMACK RIVER LOWELL..MA FLOOD STAGE IS 52 FEET. 7 AM STAGE WAS 46.n F1 CREST TO NEAR 49 1/2 FT BY THURSD AY MORNING. LAWRENCE..MA FLOOD ST AGE IS 20 FCET. 7 AM ST AGF WAS v,SG CREST BETWEEN 16 TO 16 1/2 FT HV THURSDAY F.3RNING. o =%. N ASHU A RIVER l [AST PEPPERELL..MA FLOOD STAGE !$ 8 FEET. 7AM ST AGE W AS 5.0 F T () RISE TO NE AR 9 FT BY THURSD AY EVENING. 'y HOUSATONIC RIVER () GR. BARRINGTON.MA FLOOD STAGE IS 9 FEET. TAM STAGF WAS 5 3 F1 CREST BETWEEN 6.0 AND 6 1/2 FT WEDNESDAY f. V E N I t. C. i
(. i 7 ___ _ () 8 0SFLSHf D WOUS00 f.HFD 150500 I FLOOD SeATEMENT ( f 10:24 NATIONAL WEATHER SERVICE RIVER FOREC AST CENTER, HARTFORD. CT PM EST DEC 14 1983 () - FLOOD STATEMENT FOR SOUTHERN NEW ENGLAND FLOODING ALONG PORTIONS OF THE CONNECTICUT RIVER OVER THF NEX1,FE'. (b DAYS... SOME FLOODING IS TAKING PLACE ALONG THE CONNECTICUT RIVER AT C) MONTEGUE CITY IN MASSACHUSETTS TONIGHT. IT WILL CREST ABOUT 21/2 FEET OVER FLOOD STAGE IN THIS AREA THURSDAY MORNING. AT HARTFORD WE WERE JUST BELOW FLOOD ' STAGE THIS EVENING BUT WILL G0 ABOVE (). FLOOD STAGE LATER TONIGHT. ~ MIN 0R FLOODING CONTINUES ALONG THE SOUTHERN PORTIONS OF THE HOUS A10AIC ()- RIVER. THE RIVER IS AT CREST OR HAS CRESTED AS OF TONIGHT AuD WILL GO SELOW FLOOD STAGE IN MOST SECTIONS BY THURSDAY MORNING. () SPECIFIC FOREC ASTS FOR SOUTH.ERN NEW ENGLAND... 1 CONNECTICUT RIVER () 'MONTAGUE CITY..MA FLOOD ST AGE IS 28 FEET. 7PM STAGE WAS 29.7 FT RISE TO 30 1/2 FT BY. THURSDAY MORNING.. LIT,TLE CHANGE DURING THE DAY THURSDAY. NORTHAMPTON..MA FLOOD ST AGE IS 112 FECT. 7PM STAGE WAS MSG CREST TO NEAR 113 1/2 FT EY THURSDAY MORNING. HOLYOKE..MA FLOOD STAGE IS 9 FEET. 7PM STAGE WAS MSG ^ RISE TO BETWEEN 9 AND 9 1/2 FT BY THURSDAY AFTERN0ON. SPRINGFIELO..MA F LOOD STAGE IS 20 FEET. 7PM STAGE WAS MSG FT CREST BETWEEN 15 TO 15 1/2 FT LATE THURSDAY MORNING. THOMPSONVILLE..CT 7PM STAGE WAS.4.9 FT 3 CREST NEAR 6 FT SY THURSDAY MORNING. HARTFORD..CT FLOOD STAGE !$ 16 FEFI. 7PM ST AGE WAS 15.0 F T RE ACH FLOOD ST AGE TONIGHT.. CREST TO D E AR 20 1/2 FT FRIDAY. MIDDLETOWN..CT FLGOD STAGE IS R FEET. 7PM ST AGE W AS 5.8 FT RISE TO NE AR FLOOD ST AGE THURSD AY MORNING.. CiEST NE AR 10 FT C ON FRIDAY. izlt+(s3 MERRIMACK RIVER () LOWELL. 4A FLOOD STAGE IS 52 FECT. 7PM ST AGE W AS 49.2 F T CREST TO NEAR 50 FT BY LATE THURSDAY MORNING. () LAWRENCE..MA FLOOD STAGE IS 20 FEET. 7PM ST AGE WAS #SG CREST BETWEEN 16 1/2 TO 17 FT BY THUR$0AY LATE MORNING. g) () N ASHUA RIVER STAGE WAS 5.0 ri l CAST PEPPERELL..MA FLOOD STAGE IS 8 F EET. 7PM RISE TO NE AR FL000 STAGE 8Y THURSD AY EVENING. g) fff HOUSATONIC RIVER GP. BARRINGTON.MA FLOOD STAGE IS 9 FEET. 7PM STAGF WAS 5.T FT gg (b CREST BETWEEN 6.0 AND 6 1/2 FT EARLY THURSDAY MORNIt.G.
== ....ame. ....r et 6 e nnn s i s e.e se -6.rt. vou. T a s.6 L.
- t
s 4 BOSFLSHFD 151700 Q('e,WOUSOOKHFD . FLOOD STATEMENT .'
- N ATIONAL WEATHER SERVICE RIVER FOREC A0T CENTER, HARTFORD. CT Q, ' 11:21 AM EST DEC 15 198_3
[F'LOOD STATEMENT FOR SOUTHERN NEW ENGLAND O ~ . FLOOD WARNING CONTINUES ALONG THE CONNECTICUT RIVER IN FASSACHUSETTE ' AND CONNECTICUT... O N-l. MINOR FLOODING CONTINUES ALONG THE LOWER HOUSATONIC RIVER NE AR p%.'8AYLORDSVILLECONNECTICUT.... 7TNE ' CONNECTICUT RIVER IS ABOUT 2 FECT OVER FLOOD STAGE THIS MORNING. a :-AT MONTAGUE CITY IN NORTHERN MASC ACHUSETTS BUT* H AS CRESTED AND !$ Q [.' SLOWLY FALLING. F ARTHER SOUTH IN MASSACHUSETTS AND IN CONhECTICUT
- -+,THE RIVER CONTINUES TO RISE. AT HARTFORD THE RIVER IS 2 FEET OVER FLOOD j
STAGE THIS MORNING AND WILL RISE ANOTHER 2 TO 3 FECT BEFORE CRESTING 'g L ATE FRID AY MORNING. THIS WILL GIVE HARTFORD ITS HIGHEST READING FOR l l j,T,HECALENDARYEAR. ~ l ALONG THE HOUSATONIC, THE RIVER IS STEADY OR SLOWLY FALLING AT MOST ITS FLOOD
- 3. POINTS. THE SLOW RECESSION H AS ALLOWED THE RIVER TO G0 BELOW
. STAGE AT STEVENSON IN CONNECTICUT SUT REMAINS SLIGHTLY OVER JTS B ANKS e.. Oj b NEAR NEW MILFORD CONNECTICUT., .' ELSEWHERE IN $00THE4N NEW ENGLAND MOST OF THE RIVERS AND STREAMS ARE ~ Q ' RECEDING SLOWLY. THE FEW THAT ARE STILL RISING LIKE THE MERRIMACK J4AND N ASHUA RIVERS IN MASS ACHUSETTS WILL SE SWOLLEN BUT REMAIN IN 9 Mul.. ) '4. l ALL INTERESTS IN UNPROTECTED AREAS ALONG THE CONNECTICUT RIVER IN M ASS ACHUSETTS AND CONNECTICUT ARE URGED TO MONITOR FURTHER N ATION AL Q: WEATHER SERVICE STATEMENTS AND FOREC ASTS. THE FOLLOWING ARE MORE SPECIFIC F OREC ASTS............ & O i HOUSATONIC RIVER 4 GR. BARRINGTON.MA FLOOD STAGE IS 9 FEET. 7AM STAGE WAS 5.2 FT Q fag.L TO BETWEEN 5 AND 5 1/2 FT BY FRIDAY MORNING. l GAYLORDSVILLC..CT FLOOD STAGE IS 8 FEET. 7AM STAGE WAS 8 7 FT Q* SLOW F ALL TO NEAR 8 FT BY FRID AY MORNING. l BLACKSTONE RIVER l WOONSOCKEY..RI FLOOD STAGE IS 9 FEET. 7Ait ST AGE WA 5 7.1 rT FALL TC NEAR 5 1/2 FT BY FRIDAY MORNING. Q CHARLES RIVER 00VER..MA FLOOD STAGE IS 4 FEET. TAM STAGE WAS MSG NEAR S ANKFULL CONDIT0NS NEXT 24 HOURS. ASSABET RIVER 7 RA'YNARD..MA FLOOD STAGE IS 5 FELT. 7AM ST AGE WA S MSG' } '.' CREST NEAR FLOOD ST AGE C ARLY THI,5 AFTERNDON...THEN SLOW F ALL. h l CONNECTICUT RIVER s j . - MONTAGUE CITY..MA FLOOD STAGE !$ 28 FEET. TAM : STAGE WAS 29.5 FT g SLOW F ALL
- TO NE AR 28 FT SY FRIDAY MORNING.
3 NORTHAMPTON..MA FLOOD STAGE IS 112 FEET. 7AM STAGE WAS !!9 FT es nie e.e e va rae,so sis av av resnav anestur..
l ,,-A N 0.0 'T-e.: ~ ~ rouuu s u m e r. r.. ,-n Q MU LT UKy... vin WOW NEAR CREST'. FALL 10 SETWEEN 8 AND 8 1/2 FT SY FRIDAY MGRNING FLOOD STAGE IS 20 FEET. 7AM ST AGE WAS 15.0 FT SPRINGFIELD..MA ) CREST NEAR 15 1/2 FT THURSD AY NIGHT...THEN LITTLE CHANGE OVERh1TE 7AM STAGE WAS 6 1 FT ) THOMPSONVILLE..CT NOW NE AR CSEST. LITTLE CHANGE EXPECTED NEXT 24 HOURS. O HARTFORD..CT FLOOD ST AGE IS 16 FEET. 7 AM STAGE WAS 18.0 F1 CREST NEAR 201/2 FT L ATE FRID AY MORNING. 3" ~1 'MIDDLETOWN..CT FLOOD STAGE IS 8 FEET. 7AM ST AGE W AS 7.7 FT RISE TO NEAR 11 1/2 FT FRIDAY MORNING... CREST NEAR 12 FT LATE FRIDAY NIGHT. 3 IzhMt3 ~ RIVER ) h.MERRIMACK ,LOWELL..MA FLOOD STAGE IS 52 FEET. 7AM STAGE WAS 50.6 FT n
- A' CREST 'NEAR 51 FT THUR$0AY AFTERNDON, THEN F ALL TO NEAR 50 FT BY FRIDAY MORNING.
), 5 ' LAWRENCE..MA FLOOD STAGE IS 20 FEET. 7 AM ST AGE WAS 18.2 FT ' CREST NEAR 19 FT THURSDAY AFTERNDON, THEN SLOW FALL. ),Y AlASHUA RIVER i EAST PEPPERELL..M A FLOOD STAGE IS 8 FEET. TAM ST AGE WAS b.0 FT ~ 4 WITHIN BANK RISES NEXT 24 HOURS. ); NEXT MESSAGE WILL BE ISSUED FRIDAY MORNING. j'2, f M 3 NERFC/ TM /FJL y h. -- i ( l l
.u uj nm - _ rnwwrericutJOS 1.5 8 6,10. A 7 1 ' 3 0 --. l '. fL- ,80SFLSHFD WOUSCO KHFD 161700 j s l FLOOD STATEMENT . NATIONAL WEATHER SERVICE RIVER FOREC AST CENTER, HARTFORD, CT (1:36.AM EST DEC 16 1983 FLOOD WARNING CONTINUES FOR THE CONNECTICUT RIVER IN CONNECTICUT AND M ASS ACHUSETTS. THE CONNECTICUT RIVER HAS CRESTED IN MASSACHUSETTS AND WILL BE CRESTING 4 TO 5 FT ABOVE FLOOD STAGE IN C3NNECT! CUT.
- THE CHARLES RIVER AT D0VER WILL CREST.1/2 FOOT ABOVE FLOOD ST AGF j S ATURD AY EVENING.
THE HOUSATONIC RIVER IS NOJ WITHIN ITS B ANKS AND WILL CONTINUE TO F ALL ) SLOWLY. ) THE MERRIMACK IN MASSACHUSETTS NAS CRESTED NEAR FLOOD STAGE AND WILL BEGIN TO FALL SHORTLY. J' THE FOLLOWING ARE. ARE MORE SPECIFIC FOREC AST S........ d GAYLORDSVILLE FLOOD STAGE IS 8 FEET. 9 AM ST AGE WAS 7.6 FT FALLING TO BETWEEN 7 TO 7 1/2 FT SATURDAY MORNING k STEVENSON FLOOD ST AGE I S 12 FEET. 9AM STAGE WAS 10.3 F T FALLING TO NEAR 9 1/2 FT SAT MORNING. CONNECTICUT RIVER MONTAGUE CITY FLOOD ST AGE IS 28 FEET. 9AM STAGE WAS 26.9FT LITTLE CHANGE NEXT 12 HOURS BEING 271/2 TO 28 FT S ATURDAY M0kNING NORTHNAMPTON FLOOD STAGE IS 112 FEET. 9AM STAGE WAS MISSIAG F ALL T O 112 T O 112 1/2 FT SATURDAY MORNING. HOLYOKE FLOOD ST AGE IS 9 FEET. 9 AM ST AGE WAS MISSING FALL TO 77071/2 FT SATURDAY MORNING. SPRINGFIELD FLOOD ST AGE IS 2 0 FEET. 9AM STAGE WAS 16.0 FT WILL FALL TO NEAR 14 1/2 FT SATURDAY MORNINS. THOMPSONVILLE 9AM STAGF wAS 6.5 FT N0W AT CREST, WITH SLOW FALL NEXT 24 HOURS BEING 6 T O 6 1/2 F1 ' SATURDAY MORNING. .I ,,h} HARTFORD FLOOD ST AGE IS 16 FT 9AM STAGE IS 20.7 FT N0J NE AR CREST. WILL ST ART RECEDING L ATE THIS EVENING F4LLING TO NEAR 2 0 1/2 FT SATURDAY MORNING. d 4 0 = 'l BODKIN ROCK NR MIDDLET0WN FLOOD STAGE IS 8 FT 9AM STAGE WAF. 10.5 FT 1/2 FT S ATURD AY) MORNING WITH SLOW F ALL T d CREST NE AR 11 l-LI2bil vs CHARLES RIVER D0VER FLOOD STAGE IS 4 FEET. 9 AM ST AGE WAS 4.1. F T CREST NEAR 4 1/2 FT SATURDAY EVENING. MERRIMACK RIVER LOWELL FLOOD ST AGE IS 52 FEET. 9 AM ST AGE W AS 50.9 F1 NOW CRESTING. FALLING TO NEAR 49 1/2 FT SATURDAY MORh1NG. ) THE NEXT MESSAGE WILL 8E ISSUED SATURDAY MORNING. ""' c 'c' 5 iz/es - r
BOSFLSHFD W OUS 0 0 KHF D 1717 0 0 FLOOD ST ATEMENT CENT ER, H ARTF ORD. CT N ATIONAL WEATHER SERVICE RIVER FOREC AST EST DEC 17 198{ ($ [10153 AP RIVCR IN Cor NECT ICUT. FLOOD WARNING CONTINUES FOR THE CONNECTICU RIVER w!LL ABOVE FLOOD STAGE. THE CONNECTICUT AT LEVELS 4 TO 5 FT SEGIN TO RECEDE VERY SLOWLY TODAY. LONG AND BROAD CREST FOR THE THIS HAS BEEN AN UNUSU ALLY EONNECTICUT RIVER IN CONNECTICUT THE FOLLOWING ARE ARE MORE SPECIF IC F OREC AST S........ FEET. T AM ST AGE W AS 6 9 F1 GAYLORDSVILLE FLOOD STAGE IS 8 FALLING TO BETWEEN 6 90 6 1/2 FT SUNDAY MORNING. CONNECTICUT RIVER FLOOD ST AGE IS 28 FEET. TAM STAGE WAS 27.bFT MONT AGUE CITY MORNING. F ALL TO 261/2 TO 27 F T SuhD AY SLOW FLOOD STAGE IS 112 FEET. TAM STAGE WAS HISSIhG ~. NORTHHAMPTON 1/2 FT SUND AY MORNING. FALL TO 111 TO 111 FLOOD STAGE IS 9 FEET. T AM ST AGE WAS 8.? HOLYOKE io 61/2 TO 7 FT SUND AY MORNING. FALL FLOOD ST AGE IS 20 FEET. TAM ST AGE W AS15 6 FT SPRINGFIELD WILL FALL TO NEAR 14 FT SUNDAY MORNING. 9AM STAGL WA0 6.3 F1 THOMPSONVILLE SLOW F ALL NEXT 24 HOURS TO 5 1/2 TO 6 FT SUND AY MORNING. HARTFORD FLOOD STAGE IS 16 FT 10AM ST AGE IS 21.0 F T F ALLING VERY SLOWLY TODAY TO 20 70 20 1/2 F T SUND AY M IS 8 FT 10 AM STAGE WAS 11.7 F T fBODKINROCKNRMID'DLETOWNFLOODSTAGENOW NEAR C 24 HOURS.. FLOOD ST AGE IS 4 FEET. 9 AM ST AGE WAS MSG. CHARLES RIVER DOVER FALLING TO 4 FT SUNDAY MORNING. ~ 9AM STAGE WAS 50.2 FT MERRIMACK RIVER FLOOD ST AGE IS 52 FECT. LOWELL MORNING. F ALLING TO NE AR 48 1/2 F T SUND AY THE NEXT MESSAGE WILL BE ISSUED SUNDAY MORNING. v (b NERFC/LJM/CSH r l l Z / B3 - I, C) >
- , ;,3 w.
- - - ~. - - - j l fbY l$ 18 1 ISU$30 IDFB SS1000 1 1 WGENT IPLOOf WANING...PMT I 0F R 1 SEWIDNA WATER SERYlCE R!WR FORECAST CENTER. HARTFORD, CT j.Mi38 PM EST APR 95 1964 i MTIONAL MATHER SERVICE HAS MCLMED A FLOOD WRNING FOR I eqECTICUT MD MSSACHUSETTE EST OF THE CONNECTICUT RIWR . SMS iftTCH REf9t!NS IN EFFECT FOR PRSSACHUSETT5 MD CONNECTICUT gfOFTmCONNECTICUTP!wR. I ha$ b SYSTEM HAS POVED INTO SOUTERN HEW ENGLMD.. 9RINGlHG EAW AINE INTD THE Aera. RAINFALL TOTALS AS OF F AM THURSDAY ERE IMMRALLY SETbEEN 1/2 MD 1 INCH...WITH UP TD 2 INCHES REPORTED IN FAIR-jFIELD COLMTY IN CONNECTICUT. LESSOR APCUNTS ERE REPORTED IN EASTERN ...hMERE HEAW RAINS ME JUST STMTING. . AD81710POIL MAW RAINFALL IS EWECTED DURING THE DAY THLRSDAY. RUNO.' FMIM THIS RAIN...C0rWINED WFN FELTING SHOU...WILL CAUSE RAPID RISEF IN MEA R!WRS AND STREArS. Sort Sf14LLER STREAPS IN LESTERN PARTS W CONNECTICUT MD PRSSACHUSETTS ARE ALREADY MEAR BANKFULL CONDITIONS. ' AS, f9EE RAIN FA' LS... MINOR FLCODING CAN SE EWECTED IN Pf%Y MEAS. LARGER RIWR$ IN SOUTHERN HEW ENGLRND WILL REACT LATER IN THE DAY 1MJRSDAY. MINOR FLOODING CM SE EWECTED BY FRIDAY PDRNING AT THE POLLOWING LOCATIONS... n 715 COMMCTICUT RIVER DEThEEN SPRINGFIELD...PR MD HARTFORD...CT BS MOUSATONIC RIVER MEM MEW MILFORD AND STEWMSON...CT M TMNTIC RIVER MEM NORWICH...CT PARMIMSTDM RlWR NEAR StrS5U(Y...Df M CMRLES RIVER MM DOVER...fft M ASSABET river MERR f9tvHARD...fft k M m.ACKSTONE alW R MEAR MORTHeRIDGE...t9e IF SLR091HG OCCURS IN VDUR AREA...IT IS WISE 70 FOLLOW A FEW RULES. 9Wf 191 tti CROSS FLOO MD ROADS AMS M IDGES. THE nmTER MISHT BE i a..De turt DOE THE RIWRS FOR RECREAT10NAL PURPOSES... AND DO NOT LET 'wsR aufteREN PLAT MEAR RISlHS RIVsRS MD StasAMS. 1 s.gginUCTIOns OF LOCAL Clv!L DEFENSE MD LAW EnFORCtesNT i -m y. L+'u.
- 4 -1 A
- c;>;... - a b D 001000
- DIA.LETIM f PLDOp 151RNING l
I MATIONAL bEATNER SERVICE RIVER FORECAST CENTER. HARTFORD. CT { 12:33 PM EST APR SS 1984 e [ TM FOLLOWING ME ME tere SPECIF IC FORECASTS........ y" MlpSATONIC R!WR -I .! GREAT SARRINGTON FLOOD STAGE IS 9 FEET. FAN STAGE WRS 3.9 FT j -] R19E TO MEM F FEET BY FRIDAY EVENING. 3 FLOOD STAGE IS S FEET. FAN STAGE WAS 5.6 FT l SAYLOR98VILLE f I WILL REACH FLOOD STRGE OF B FT. THURSDAY EVENING. STEVENSON FLOOD STAGE IS 12 FEET. FAN STRGE IJts 3.2 FT ', I WILL REACH FLOOD STAGE OF 12 FEET THURSDAY EVENING. pCENGECTICUT RIVER 1 iPWNTRGUE CITY FLOOD STAGE IS 28 FEET. FAtt STAGE b5tS 16.3 FT l r, 8 RISE TO MEAR 24 FEET BY FRIDAY fMRNING. MDLYDKE FLOOD STAGE IS 9 FEET. FAM STAGE W S PEG. r RISE TU BETbEEN 6 AND G I/2 FEET FRIDAY ISRHING. OPRINGFIELD FLOOD STAGE IS 29 FEET. FAM STAGE IJtS F.1 FT RISE TD MEAR 13 1/2 FEET FRIDAY PORHING. E.! I U TigNPSONVILLE FAN STAGE WS 2.4 FT 3 "*I RISE TD MEAR S FEET SY FRIDAY PORNING. i FLOCD STAGE 18 15 FEET. FAM STAGE WS 10.9 FY f [ WIRTFORD I RISE TD NEM FLOOD STRGE OF 16 FEET FRIDAY FORHlHG. [A j jMIDDLETOLN FLOOD STAGE 15 8 FEET. FAN STAGE buts 4.8 FT AltE TD MEAR 5 FEET BY FRIDAY ttRNING. ~l w!. f CMJCAREE RIWG GMMAN ORCHARD FLOCD STAGE 15 12 FEET. FAM STAGE WRS 3.3 FT , f ,ie
- A1SE TD MM 11 1/2 FEET FRIDAY FORHING.
d I FMMIMGTDM RIVER /
- SIPSSURY FLOOD STRGE IS 12 FEET. FAM STAGE b5tS F.T FT 2 RISE TO MM FLOOD STAGE OF 12 FEET THURSDAY EVENING.
g J -d 1au:iCx3 tom river S {
- MORTMRIDGE FLOOD STAGE IS 9 FEET. FAM ETRGE 6545 5.9 FT 6
RISE TD MEM 9 t/2 FEET EARLY FRIDAY FORNING. r
- hm0NSOCKET FLOOD STAGE 15 9 FEET. FAtt STRGE WR$ 4.8 FT j
RIM TU DEAR S 1/2 FEET FRIDAY PORNING. (TIC A!WR FLOOD STAGE IS S FEET. FAN STRGE WAS EST. 8 FEET'/ 4EIAWICH 7.q',! IllSE TD DEM 91/2 FEET THURSDAY MIGHT. EsthT"CKET RIVER I'1MILLIP9lMTIC FLOOD STRGE IS 13 FEET. FAN STAGE b5tS 5.0 FT 4 jtE TO MEAR 10 FEET FRIDAY PCRNING. R CMARLES RIVER BOVER FLOOD STAGE IS 4 FEET. FAtt STAGE 65tS PSG [ MIM0R FLOODING MExT FIW DAYS. i RSSABET RIWR I PWhyMARD FLOOD STAGE IS S FEET. 76M STAGE buts 4.2 FT 9 -J RISE TD NEAR DANKFULL CONDITIONS FRIDAY PCRHING. pgERl[WlCRRIVER si ann *:ve.w ie r, . tTa r IJnt 48.5 FT -....u m..
~ v. r-k. i WUtse logrD 968000 PLIMID STRTEffMT Sq$AL bEATNER SERVICE RIWR FORECAST CENTER HARTFORD, CT De PM SST APR 95 1984 MD.agutNING REF911NS IN EFF5GT.fmSSACMUETTS MD CopeECTICUT y 0F,7NE CONNECTICUT RIVER.
- LOOD hflTCH RErft!NS IN EFFECT FOR SOUTHERN MEW ENGLAND EAST OF CepeSCTICUT RIWR.
RS CONTINUE TD FALL OVER SOUTERN HEW ENGLAND. SOUTHESTERN qT! CUT HAS RECE!WD THE HIGHEST AFSUHTS...WITH STORM TOTALS REf 3 /2 INCE S IN SPOTS. THE REST OF THE STATE RECEIVED DETkEEH 1 AH) ] y/3 INCHES. RHODE ISLAND HAS RECORDED BETLEEN 1 AND 2 INCHES SO f 5seSACHUGETTS HAS RECE!WD DETLEEN 1/2 MD 1 1/2 INCHES...WITH EASTI = f w u m TTS RECEIVING THE LOE R ArSUMTS. .q ~. MINOR FLOODING MAS BEEN REPORTED ON St9tLL RIVERS IN bESTERN AREAS Of CONNECTICUT MD tW4SSACHUSETTS. THE NORWILK R!vER hms DVER ITS BANK! l tdAR WILTON...CT EARLIER THIS AFTIRH00H.. THE SAUGATUCK AlWR 18 SE N TO BE IN FLoca,, SOUTH OF SAUGATUCK... CONNECTICUT. 9F THE LARGER R! VERS IM THE AREA...THE HOUSATONIC RtWR IS OVER 1TS BANKS IN THE STEVENSON...CT AREA... AND WILL GO OVER ITS - j 94HKS IN THE NEU MILFORD...CT.. 4RE A SY TH18 EWHING. OTNER RtWR8 SWECTED TO REACH THEIR FLOOD STAGE BY FRIDAY FCRNING '{ICLUDE THE CONNECTICUT RIVER NEAR HARTFORD...CT...THE FARMINGTDH ! 44)4R MAR Str50VRY...CT... AND THE BLACKSTONE RIVER AT NORTHSRIDGE } Lfm AND bOONSOCKET...RI. - w-i THE FOLLOWING ARE ARE tere SPECIFIC FORECASTS........ .j'$5CSATDMIC RIVER l Q GREAT SARRINGTDH FLOOD STAGE IS 9 FEET.1PM STRGE hmS 3.9 FT RISE TD SEThEEN F 1/2 AND 8 FT BY FRIDAY FCAN!NG. ) .5AM.ORDSVILLE FLOOD STRGE IS S FEET. IPM STAGE bh5 T' ! FT I
- 5 R18E TD MEAR lt FT BY FRIDAY PCRHING.
i j STEWMSON FLOOD STAGE IS 12 FEET. IPM STRGE bas 13.5 FT "L-j RISE TD BETkEEN 15 AND 15 FT SY FRIDAY PORHING. 4* ~ CTICUT RIVER ICHTRGUE CITY FLD0D STAGE IS 29 FEET. IPM STRGE bat 1F.7 FT y RISE TO MEAR 2E FT SY FRIDAY #CRHING. Ig, ORTWAPPTDM s.
- h.. N FLOOD STRGE IS !!2 FEET. IPM STAGE bms MISSING
,.. lSE TD MEAR 111 FT SY FRIDAY PORNING. p I NGFIELD FLOOD STAGE IS 28 FEET. IPM STRGE WAS T.9 FT g I,pE TO NEAR 13 FT SY FRIDAY FORHING. THOPPSONVILLE 1PM STAGE WAS 3.5 FT ~3 i RISE TO MEAR 5 FT SY FRIDAY PORHING. $WIRTFORD FLOOD STAGE IS 16 FEET. IPM STAGE bas 10.5 FT g, RISE TD HEAR SANKFULL CONDITIONS SY FRIDAY FORHING. g FL0bDSTRGEISSFEET.IPMSTAGEbas4.TFT ~MIDDLETDbH RISE TO BETLEEN S AND S 1/2 FT BY FRIDAY PORHlHG. F W INGTON RIVER iSitE8URY Ti.00D STAGE IS 12 FEET.1PM STAGE has 3.3 FT -3 RISE TD MEAR 13 FT BY FRIDAY PCRHING. BLAICESTONE RIVER ogo.e vxr, e.. w
~ - - - S KMFD 988500 9 STRTEPENT NRf'llmAL nEATHER SERVICE RIVER FORECAST CENTER. HARTFORD. CT
- lte$ Pff EST APR 85 1984 7)g g PG$ STWTEPENT FOR SOUTHERN MEW ENGLAND...PART I '0F 2 i
,' l. SBS&ERS CONTINUE TO FALt IN SOUTHERN E W ENGLAND. PRECIPITRTION TOTRLS IMl COMECTICUT AS OF 7 PM FOR APRIL 4 TD APRIL 5 STORM GENERALLY RANGED FROM i 1/2 TO 2 1/2 INCHES...WITH SOff SPOTS IN SOUTHESTERN CONNECTICUT i AttlE!VING E LL OVER 3 1/2 INCHES. PSIS$RCHUSETTS PRECIFITRTION GENERALLY RA4 SED FROM i 1/2 TO 21/2 INCHES...WITH SLIGHTLY LOER AfeUNTS ALONG i THE COAST. RHODE ISLAND ALSO REPORTS BETW EN 1 1/2 TD 2 1/2 INCHES... hl SNDERS CONTINUING. I MI WR FLOODING MAS OCCURRED ON SmLLER STREnts IN ESTERM AREAS OF P0tMECTICUT AND PMSSACHUSETTS. THE EAST AND E ST BRANCHES OF THE MJGATUCK RIVER NORTHEST OF BRIDGEPORT bERE OVER THEIR BANKS...AS ERE @ tLL STREAPE IN THE BAKERSVILLE...CT AREA...NEAR TDARINGTON. 99tNY OF STREarS WILL REfft!N AT HIGN LEVELS THROUGN THURSDAY NIGHT. e L M RIVERS HAVE ALSO BEGUN TD REACT TO THIS STORff. THE HOUSATONIC A!WR IS ALREADY EWERIENCING MINOR OVERFLDE IN THE NEW MILFORD...CT AREA AND NEAR STEVENSON...CT. OTHER RIVERS EWECTED TO REACH FLOOD i $7tGE SY FRIDAY 79RNING INCLUDE THE CONNECTICUT RIVER NEAR MARTFORD...CT ...THE FARMINGTON RIVER NEAR SitGBURY...CT...THE LESTFIELD RIVER AT lESTFIELD...fm...THE ASSABET RIVER NEAR PWIWARD...PWI...AMD THC BLACKSTOE RIER AT SOTH NORTHORIDGE..f9 AND bDONSOCKET...RI._ _ . OSOFLSHFD ' IRlWSSG KWD B59488 FLfM p SERTEFENT i , ftl0 0NAL LEATHER SERVICE RIWR FORECAST CENTER, HARTFORD, CT ' !$s3 1 Pfl ES T APR BS 1984 6 $tf 3 F 2 ' ' SIII JC FORECASTS FOR THE CONNECTICUT, PERRIP9tCK, NASNUA, CONCORD, AND C$1 RIVERS IN SOUTHERN HEW ENGLAND. fNieECTICUT RIVER PENTRGE CITY..PWI FLOOD STRGE IS 28 FEET. FPf1 STRGE hm4 28.1 FT MACN FLOOD STRGE SY FRIMY PORNING. i--vsvM..fm RfSE TD EAR !!3 FT SY FRIDRY #9RNING. FLOOD STAGE IS !!2 FEET. FPf1 , j !!DE NIE..t9 FLOOD STRGE IS S FEET. FPM STAGE 65t$ MIS $1NG bE TO EM S FT SY FRIMY FWRMING. R1 MRINIFIELD..IS FLOOD STAGE 18 28 FEET. FPf1 STRGE 4m5 MIS $1NG
- RISE TO EAR 121/2 FT SY FRIMY PORNING.
a h WPPSONYlLLE..CT FPf1 STRGE nfts 2.0 FT
- RISE TD NEAR S FT SY FRIMY PCRNING...THEN CONTINUED RISE.
t
- letRTFORD..CT FLOOD STAGE IS !$ FEET. FPf1 STAGE 6m5 !!.2 FT RISE 19 FLOOD STAGE SY N00N FRIMY...THEN CONTINUE TD RISE.
! MIDDLET0lef..tf FLOOD STAGE 18 9 FEET. FPM STRGE buts 5.2 FT
- RISE TO FLOOD STRGE SY FRIDAY EVENINE...TNEN CONTINUED RISE.
== EMlfstCK N!VER ' ' &ahELLaPet FLOOD STAGE IS S2 FEET. PPPI STAGE nfts MISSIMS RISE TO NEAR 481/2 FT SY FRIMY #9ANINS. AptflWTWfAlWA FLOOD STRGE 18 12 FEET. SPM STRGE nmS 11.2 FT 2] g 4/ sitssurf..tt l RIBE TU FLOOD STRGE BY MIDMITE...NFAR 14 FT SY N00N FplMY. 7 ( .....~ ~ ' ~
- g = - - Ew"
'b. ?! soSFLsMFs ' hEIUsesiolFD e$less j MOD 5 rwntsNT ' tWi[IOMi% WATHER SERVICE RIWR FORECAST CENTER. HARTFORD, CT H I!$ All EST APR SS 1984 i l' i gNIS STRTEPENT FOR SOUTERN MEU ENGLAND...PART I 0F 2 p '4RS IN CONNECTICUT...THE CONNECTICUT RIVER IN P9tSSAC64JSETTS AND4.0
- g i
CTICUT...MD THE BLACK $7DNE RIWR IN RHODE ISLAND. ? s* Y 78187 0F THE SemLLER STREArs THAT ROSE ASOVE TMIR SANKS ON TIGASMY IN < hESTERN AREAS OF SOUTHERN MEW ENGLAND HAVE CRESTED AND ME ON THE hmY 901At. THE hESTFIELD RIVER...WICH hms A80W ITS FLOOD STAGE IN bEST-i d F1 D...fm THURSDAY MGNT AND FRIMY retMING...!$ BACK MLOW ITS SANKS i l RECEDING. THE YZTIC RIVER CRESTED LATE THURSDAY NIGHT JUST INCHES ) j p ITS FLOOD STAGS AT NORWICN...CT. l. k GTTENTION IS NOW FOCUSED ON THE LARGER RIVERS IN OUR AREA I S.0hER TO REACT. THE HOUSATDNIC RIVER !$ NOW NEAR CREST MAR NEW i MILF08tD...CT... AMD IS ALREADY RECEDING IN THE STEVENSON...CT MEA. Gtt0E FLOODING WILL CONTINUE ALONG 7HE HOUSATDNIC R!WR IN CONNECTICUT , @1 PRIDRY. ' TIE COMMECTICUT RIVER !$ SLIGHTLY ASOVE ITS FLOOD STAGE IN THE FSNTAGUE t CITY...PWI AREA...MD IS EWECTED TD CREST THERE FRIDAY AFTERNOON. IN t M MARTFORD...CT AREA...THE RIVER WILL REACN ITS FLOOD STAGE SY FR2MY 5 AFTERNDON... AND WILL CREST SATURDAY AFTERNOON. THE RIVER WILL REACH ! PLD00 STAGE IN THE MIDDLETD4At...CT AREA LATE FRIDAY... AND WILL CREST i t 4 ATE SATURMY. MINOR FLOODING CAN N E FECTED ALONG THE CONNECTICUT J (JWR FOR THE MENT FEW MYS. l M SLA KSTONE RIWR WILL CREST FRIMY EVENING 1 1/2 TO 2 FEET ABOVE ITS FLOOD STRGE NEAR bE10NSOCKET...RI. MINOR FLOODING WILL CONTINUE THROUGN j SAFURMY PERh!NG. l l Nb!METON RIVER WILL CREST 2 FEET A80VE ITS FLOOD STAGE EARLY j FRIMY AFTERNOON IN THE SIPESURY...CT AREA. MINOR FLOODING WILL CON-T!8SJE THROUGH SATURMY PSNINING. ' PRECIP!TRTION TOTALS FOR THE APRIL 4 TO APRIL 8 STORM IN C0petECTICUT 3 HEM 2 TO 3 IMCNES IN EASTERN SECTIONS..1 1/2 TD 2 INCHES IN CENTRAL PORTIONS...AMD SENERALLY 2 TD 3 INCHES IN bESTERN SECTIONS...WITH Sort M IN FAIRFIELD COUNTY RErrtVING ELL OVER 31/2 INDES. IN PWISSACNUSETTS... PRECIPITATION TOTMLS VARIED WIDELY IN THE WS1ERN PART OF THE STATE. ThE3 TO THitEE INCHES ERE CorMlH...BUT Sorf LOCALLY ISAW SHOERS PRODUCED IN ETESS OF 31/21NCHES. CENTRAL SECTIONS OF TM SAY STATE RECEIVED MThEEN 1 1/2 AND 2 INCHES... AMD EASTERN SECT 10MB MCElVES SEThEEN i AND 2 INCHES. G WWE ISLAND RECEIVED Bl.ThEEN 3 AND 31/2 INDES. 'llE PERRIP9tCK RIVER IN EASTERN PWISSAD4l8ETTS WILL CREST MAR BApeuruLL. . CIDSITIlplS. MfMR fESSAGE WILL FOLLOW CONTRIMINS SPECIFIC FORECASTS. f 'wCm 3 .h0:f
- .[
4/rq.c a e, .. -.m. - ---
R } 3am.e*> uMFs Os170s D STRTEfENT I 10 MAL' WATHER SERVICE XIVER FORECAST CENTER. MARTFORD. CT 4(ale Art EST AMt 85 1984 %[, i 1 tT 2 W 2 POLLIhllMG RRE fGRE SPECIFIC FORECASTS........... 4JBATOMIC RIVER I FLOOD STRGE IS O FEET. Fart STAGE lets 9.4 FT
- f..:
SAYLORDSVILLE..CT el IWW IEAR CREST. FALLING WITHIM ITS BANKS BY MTURMY PWRMING.
- 4.l
//jSTEVEMON..CT FLOOD STAGE IS 12 FEET. Tart STRGE WS 13.4 1 l 1815 CRESTED. FALLING WITHIM ITS BANKS SY SATURDAY FCRMING. ISJWt4 TOM RIVER .e ISRTWitIDGE.. Pvt FLOOD STAGE IS 9 FEET. Fart STAGE WS 5.5 FT IWW CRESTING. FALLING TO MEAft 6 FEET SATURMY lTNtMING. ,SAMSOCKET..R! FLOOD STRGE IS S FEET. Fart STRGE lath 19.9 FT I CREST IS 1/2 TO 11 FEET THIS EVENING... FALLING TD 9 FT SAT FSNIM. T RIVER 'rul19tAftB..P54 FLOOD STRGE IS S FEET. FAf1 STAGE WS 3.1 FT f 1, '.. NOW AT CREST. SLOW FALL LATER TODAY. hi -.WBTFIELD E!WR bi: hESTFIELB..f94 FLOOD STAGE IS 14 FEET. FAri STAGE SJ4512.2 FT. y NAS CRESTED. SLOW FALL TODAY. t-I i M S RIVER i 1- ..Pfl FLD00 STAGE 15 4 FEET. Fart STRGE WR$ PSG. } ff WILL REfft!M 1 TO 2 FEET OVER ITS MMKS EXT SEVERAL MVS. i .4 'c $ECT1 CUT RIVER reMTRGuE CITY..rst FLOOD STRGE IS 2e FEET. Fart STRGE lett 29.1 FT O ~ WST MAft 29 FEET THIS MTERMOOM.. FALLING SELOW FLOOD STRGE SATURSAY. DOtTHAFFTON..f96 FLOOD STAGE IS 112 FEET. Fart STRGE WS MISSING E ( -e CREST MEAft 112 1/2 FEET THIS EVEMING. I IWLTOKE..fft FLOOD STAGE IS 9 FEET. Fart STRGE lets 5.0 FT j CREST THIS EVENING S TO O 1/2 FEET. bMDEFIELD..PWI FLD0D STRGE IS 20 FEET. Fart STRGE WS 12.5 FT ~ ..I CEST MAR 141/2 FEET SATURMY FORMING. 4.h " '3 . THOPPSONVILLE..CT Fart STEE WS 4.7 FT 3 $...i. CREST MEAft 6 FEET SATURDAY tWRMING. l HRitTFORD..CT FLOOD STRGE IS 16 FEET. fat 1 STRGE WRS 14.2 FT /* U..i WILL REACH FLOOD STAGE EARLY THIS WTERM00M AMD WILL CREST MAR t as FEET SATWDAY MTERM00M. A.6 MIDDLETOlet..CT FLOCD STAGE IS S FEET. Fart STAGE WS 6.0 FT if '@ACM FLOOD STRGE THIS MTERMOOM AMD WILL CftEST 101/2 TO 11 FEET > OM OATURMY EVENING. l i=== pullfftCK k!VER i 2, L0 ELL..fft FLOOD STRGE IS 52 FEET. Pprt STRGE WS 48.I FT I l l CREST 51 1/2 TO 52 FEET SATURMY POtMING. I ci,8 LAlatENCE..P96 FLOOD STRGE IS It FEET. FAri STRGE WRS 15.5 FT j *t-CREST dealt 18 FEET SATURDAY t9RMINS. Yl 4 etAWRMILL..fWI FLOOD STAGE IS IS FEET. Fart STAGE 1545 PSG. CREST 13 1/2 TO 14 FEET SATURMY (CRMING.
- h h-l
---,---.---,.,------,...,---------.---_-_-n
Ettit'Hr0 gr Jdi t nF.FD 071h0C FLeo. STATE"ThT C" N il ) AL WEAihlh SE4VICC 41VIC F7GEC A*T rrNTro, HARTreon. rf 11:1: A" EST A"ia 07 19 H 4_ Sg F L C.'s: ST4Trvr*.T F0R 00J T HE p r: N r a ! 4 G; :.y A F L P D m A A s !
- fi 15 I r; ErIfrT T09 THE CONortYICUT 11V:" 14 fo' rrit et g
iA t ; ' ASS A C Ht1Gr T T S... T iti F A& I r.010 ', A i r H n OS A T a yl e R I V r F 9 1. - r e.yu r r i t r J T k..AN3 THE "CARIMACK t<1VEH lh FASTE4M MAceACHileCTis. b IlE C3NNFCTirJT RIVEk C7NTINUES To R1'E FRS4 THE 3AST rtW npye ar a t 1 *, 8FE 1NOW #ELT THR90LHOUT l' A S F. A C Hil t E T T F. A N D C r'.vr t i t c tif. lie C O N':ECTitui F1VL4 elLL Hr CR E 011MC AT 5 Ta r *EET AG".Vr rtlan rir ? p l t. CONNECTICUT. SEE LFECIFIC F0nECAsTc For. YOUR L3CtLITY P 01 1 '. IlE FARMINGTCN P1VER 15 ? F t:T T OV E R F LO O D e. T A r.C A N 9 rALL!rr. Vrt" e l e.. L y Ill$ MOPrJING. THE 40HSain\\1C PIVEk VILL DE IN ITS PA*<e tAvro v 1 ' e. v. p Ih EAS1Eh4 v.ASSACHUSF115 THE "LRRlwACF # 1 VE P AT L1WrLL T e. rnitTit e lif VILL P E F ALL iG LLe JL Y LATER T CD A Y. 81N3; F L e.001 % C 00NT INUEr ALONr THE P A'JT9yri *Igra te synnr T e l. A n tj, ( T HE r 9LL':U1 NG ewi P i r. f SPECir!C FrkrcA5T5............ ' -v '4\\rr11CJT RIVER.... P' AfUr CITY.."A ILOOD 5.Tas.r 15 pa rrr1. 7 4
- tar.r VAe an.1 FT J
b1LL P E d A l " !.E A T 21 F r ri T (.D AY THEN eLOV FALL erPEr'rD. Y *
- T " A
- P T (. 'd.. H A r t a p *; e T A T. F le 112 Frrt. 7AM eTAcr ge n e S t a. e ] s t y
.ILL FE9tl1 NCAF 113 FECT FOR tirxT P4 H a 0 4 *.. P;lv'dC..*A FLOCD STACr 10 9 FRET. 7Av q*Arr.gAe v ] t e, t. r. S'" 1LL d r i a l *: 001 erE'. 8 Tr a F L E T 'It X T 2 4 HnURS. fr'INGr1EL3..MA FLOOD STAGr 1 r, 2 0 rrET. 7A* eTar,r NAt 14.( rf { '.* A r. CREST HOW... LITTLE CHAVCE 103 A Y THr'J SL3d FPLL. TICSF50NVILLL..CT Ta' STAnr use
- 6. e-rf
(< p AE Ar CREST ts0V...LITTLE CilANGE T00AY THree e L r.J rALL. HARTrotD..CT FLOOD STAST le 15 TEET. 7A* STAGr uAe 90.2 rf 7 (; JILL CRECT NEAR 21 1/? FEET EARLY SUNDAY " S R N I N G T M r".' SL *.'.'L Y F ALLING TO 23 F EET
- 0'. DAY M0h N I N G.
b MIDDLETOWN..CT FLOOD STAGE IS 8 F EET. 7Au STAGE Vit 0 6 FT RISING TC 12 FEET LATE SATUFDAY tilGHT AND CR r e.71' r l' 1/? Te l' , FEET SUNDAY AFTERNOON. { ,PRIMACK RIVER I event l'Ae '.9 r' { L0 DELL..MA FLCOD STAR.r 15 m? FCET. TA" F A L L T oe i r.'ti. NOW CRESTING...LITTLE CHANGE T00AY T H t ': eLOJ i /" LAWRENCE.. A FLn00 FTAT.T T r. 7 0 rrET. 744 % Terr *' a e a1.= et l { l N0d NEAR CREST...LITTLE CHAT.GE TOD A Y TitrN CL"4 FALL 70"T347 1 6AVCPHILL..MA FLOOD %TAGI. I S 15 Frit. 7A* STAGC VA'
- r
// g l NOW CRESTING NEAR 15 FirT...THr N *E CIN SL9W F4Lt. TSAletqT. .e 6.1 N G T ON EIVEP _ _J,31:$UUhT..CI f L ;d.D ' T A f. T l-I? rirT. 7A* ef u r i,f r is.. ri lk
~ ** l .tWD l 13 KMFD 001990 l D'.,5TATENNT OK EATNER SERVICE ElWR FORECAST CENTER. HARTFORD. CT 5 AM EST APR 90 1984_.,T u g D STATEfENT FOR SOUTHERN MEW ENGLMD 00D WRNING CONTINUES FOR THE CONNECTICUT k!WR IN CONNECTICUT AND ACHUGETTS...MD THE MASHUA...rERRimCK... ASS 40ET...AND CMARLES RlWR mSSACuuSETTS. \\ FLOOD WRNING IS DISCONTINUED FOR THE HOUSATONIC MD FARMINGTON 35 IN CONNECTICUT. CONNECTICUT RIVER IS MOW MEAR CREST IN THE HARTFORD...CT MEA...MD
- WEC11D TO CREST IN THE EARLY PSNtNING MOURS ON PCNDAY IN THE MIDDLE-4...CT MEA. MINOR FLOODlHG WILL CONTINUE ALONG THE CONNECTICUT IR IN CONNECTICUT MD IN MSSACHUSETTE SOUTH OF SPRINGFIELD FOR THE I' FEW MW.
l 3R FLOODING CONTIN'UES ALONG THE PERR!mCK RIVER MEM L0 ELL...m. 1 RIVER IS EWECTED TO FALL' DACK 'WITHIM ITS SAMKS DURING THE MEXT 24 RS. NASHUA RIVER NEM EAST PEPPERELL...m NAS CRESTED. MINOR FLOODING L CONTINUE DURING THE MEXT 24 N00RS. RSSABET RIVER AT mWARD...m IS EWECTED FALL BACK BELOW ITS SANKS ' ING THE MEXT 24 HOURS. FOLLOWING ME ME PCRE SPECIFIC FORECASTV........ ~ 4 ATONIC RIVER GREAT BARRINGTON FLOOD STAGE IS 9 FEET. Fart STAGE WS 5.84 FT FALL TO BETWEN S MD 51/2 FT BY PONDAY M j GAM.ORDSVILLE FLOOD STAGE IS S FEET. FM STAGE WRS F.9 FT SLOW FALL TO MEM F t/2 FT SY FONDAY M g STEVENSON FLOOD STAGE IS 12 FEET. FM STAGE WS 10.F FT l FALL 70 KThEEN 9 1/2 MD.10 FT SY PCMDAY M L l 9ECTICUT RIVER I l l PONTAGUE CITY FLOOD STAGE IS 25 FEET. FM STAGE WS 20.1 FT i FALL TO MEAR 28 1/2 FT BY PCMDAY M 'L' l MORTHAFFTON FLOOD STAGE IS 112 FEET. FM STAGE WS MIS $1NG FALL 10 DEM 111 1/2 FT SY FONDAY M DELYOKE FLOOD STAGE IS 9 FEET. FM STAGE WAS MISSING j FALL TO DETEEN F MD F 1/2 FT SY ISMDAY M SPRINGFIELD FLOOD STAGE IS 28 FEET. Fart STAGE WS 15.4 FT SLOW FALL TO MEM 15 FT BY FSMDAY M Fart STAGE l#tS S.38 FT 3
- THOFFSONVILLE SLOW FALL TO MEAR S FT BY PCNDAY Art HARTFORD FLOOD STAGE 15 IS FEET. Fart STAGE WS 21.51 FT Y MOW AT CREST...LITTLE CMANCE lEXT 24 HOURS l
^ 0 IMIDDLETOW FLOOD STAGE IS S FEET. FAtt STAGE latS 12.9 FT I CAEST MEAR 12 1/2 TO 13 FT EARLY teMDAY M "[ WM HCTNl l'MR
n s _ BOSFLSHFD' WOUS00 MHFD 091800 FLOOD STATEMENT N AT10N AL WE ATHER SERVICE RIVrq F09EC ATT CENTrp, HARTraR9, CT 11:04 AM EST APR 09 19R4 Mpq FLOOD STATEMENT FOR SOUTHERN NEW [ NGL AND ,' ' FLOODING CONTINUES ALONG THE CONNECTI CUT RIVER IN COUNTET1 rut. THE RIVER IN CONNECTICUT HAS CRrSTED 4.5 TO 5.5 rrET ABOVE FLOOD *TAGr. THE RIVER WILL SH0J LITTLE CHANGE OVER THE NrXT I? HOU#9 Tern WILL J FALL SLOWLV FOR SEVERAL DAYS. THE CH ARLES RIVER IN EASTERN M ASS ACHU'.ETT S IS NnW C#CCTING Tun Frri DVER FLOOD STAGE. IT JILL REMAIN ABOVE rLO3D STAGE FOR TdE NEXT SEVERAL DAYS. ELSCWHERE IN SOUTHERN NEW ENGL AND MOS T RIVERM ARC WITHin THr f o BANKS AND ARE RECEDING. SPECIFIC r0 REC ASTS ARE A S FOLLOWS..... CONNECTICUT RIVER MONTAGUE CITY..MA FLOOD MTAGE IS PB FCF T. 7At STAGr VAC ?6 1 r f CONTINUED SL3WLY F ALLING TD NE Au 24 FT HY TJEMDAY A" NORTHA9PTUN..MA FLOOD ST AGF IS 112 ' EFT. 'iAM 'T A r.C Vt' 41 '. '. I *. 5 CONTINUED SLOWLY FALLING T3 NEA* 110 RY TUESDAY A" HOLYOKE..MA F L930 ST Ar.r l e, 9 FCET. 7AM STAGr J%S "f%ti"O CONTINUED SL34LY F ALLING TO NE AD 6 FT uY TUES9AY A" ,1 $PRINGF IELD. 4 A FLD0D STAGE IS 20 FEET. 744 C T A a, r sac 14.57 et e SLOWLY FALLIN"3 T3 13 - 13 1/2 r f 9Y TyfSD AY AM i k, THOMPSONVILLE..CT 7A* STASr yAs 5.,n r1 l SLOWLY FALLING TO NEAP 5 1/? FT PY TJE? DAY A* HARTFORD..CT FLOOD iTAGE IS 16 FEET. 7Aq c1&Gr Jat pt.4a r1 t FALLING TD NEAR 20 FT HY TurS3 A Y A* ann 18 T PY Jrm. peg Cetsk MIDDLETOWN..CT FLOOD STAGE IS a FEET. 714 97AGr vac 1;,g ry 3 SLOWLY FALLING TO 11 1/? T3 17 ri nY Tur. 18 A *;9 NrAr jr rf.' E *. MERRIMACK RIVER LOWELL..MA FLOOD STAG" IS 5? FEET. 7A* ( T a r, r 'g A
- st.4 1
CONTINUED SLOW FALL TO NEAR 50 1/2 ri Py TJEspey av LAWRENCE..MA FLOOD !TAGE IS 20 rrET. 7A* % tar,E VAi *l1 e e l'e ' SL0dLY FALLING TO NEAR 16 FT BY TUF'3AY A*. ~ NASHUA RIVER CAST PEPPERELL..dA FLOOD STAGF It B FEET. 7A* STAR.r vre i r.. A 8' Y FALLING TO NEAR 6 TO 6 1/2 FT HY TUESDAY A* CHICOPEE RIVER INDIAN ORCHARD..MA FLn90 STAGE 1% 12 rrrT. TA* S T A *. E *.' A ". yNa ,,,JAWMINGTON 81VEk
g. 7,.y". %.1,,. ). ..f f.,. 0use.L9ep 2 i l .pg g33333 3... Ru Ew@ M on' la G Wit 8 AlWA PGASSAST CENTER. MAATFDAD. GT e t
- " "1 ~*iMS FSA "SSWTMERM MSW EMakhMD Lupd R O sme,
.?" m - Ph004 tflRN l93b 10 IN BFFECT FOR TME ALL er TMs MeusATOMIc aIvtm 1M MD C4MMscTICWT.THE PARMIMET9M A1vsR IM SIMesORY. AND QTF646941494 IN retssmeMWstTTs... teneplat PM Stattsta nivses ans steenee esauswa $N sPPscT FOR TMs of M16he SF somnaattsut aps tMs assasMinse or mesacaussive. .reWiht ttehN StstaM Mas Fessocas estwssa 4 in to e twcass or m en Two instunH poetiswa or poissacwusstes m N N i i les tatHss mas FactsN IM esHtna6 roatisms se soutusaN Msw . 9Nie pasa Pltat:6N Mas towess stsHtPtemnf assas IN masm stRamns T e e. F W un.L stespHs WILL esslM to ksessa Lave TON!sHT SUT TMs LmAssa RIVsAs 4 centlnus 93 Als: Tm susH THs day WsDMasDaY. .3 8CIPit PtREtatts To POLLOW... ?! CUT AlWR' 4 41179 80E C it Y.itWI FLOOD tin 4E 18 38 FRET. FFM STAGE ms 34.F Ft RISE te BathsEM 36 les AHs SF FEET sy renNING...THEM CONTIMWE f A!SIMts: TMar9tDH..tfl FLOOD STAGE 18113 FEET. FPM STRGE WS MISSING. l RISE T9 MEAR FLOOD STm4E BY PENtNING...THEN CONTINUE RISING.., M W KEs.tfl FLOOD STAGE 18 9 FEET. FPM STAGE LMS MISSING ~ - RISE TO MEAR f 1/2 FEET SY PENtHING....THEN, CONTINUE RISING.. WRIMeFittla atst FLOOD sTnat IS 99 FEET. FPM STRGE hmt MISSIMO Rist To NEnt il PEET of renHlHG...THEN CONTINUE RI3lHG... h !LLE..I'.t FPM STRGE WS 2.F4 FT ). . R!st To MEAR s FEET BY ttNtHINs.. THEM CONTINGE RISING...
- RTFeeb..tt FLOOD STRGE 1815 FEET. FPM STAGE hms 9.4 FT 3
RISE TO FL90b STAGE BY MID PENtHING...TMEN CONTINUE RISlHG... 'T'ihl+o* fro #> I 4WDDLEt9hM..Ct FLOOD STRGE 19 9 FEET. PPM STAGE WRS 3.5 FT l AlSE TO MERA 8 les FEET SY PENtHlHG...TNEN CONTlHUE RISING... b Mh dP Ls *** M AlWA 44 HELLS 4991 FLOOD STAGE IS 52 FEET. PPM STRGE bett 45.1 h hy Elsa To NEAR ar.e FEET sY reRMinG... A ~ l k Wert ed. 2 J3' - agge 'en TAM eRCHAns..hn FLOOs Staat is in FsEt. FFM sTAst al Mlesins & MM h4 g it slet to NEAa a PEET eY tenw!Ms. I u T'8sM4 Alwit 14fS8WWt sCT FLOOD STRGE 15 18 FEET. FPH STRSE WAS 9.1 Ft af
- p RISE TO HEAR PLOOD STRGE AFTER MIDMIGHT THEN TO BEThEEN II 1/2 64.8 FEET ltY NHtHING.
f TOMIC AlvER i S. GAARINGTON.rWL ' FLOOD STmGE 18 S FEET. FPM STAGE WAS 6.F [ Sitt 79 MEAR FLOOD STAGE BY toAMIMG....THEM CONTIMUED RISING... WNLORDSVILLE..CT FLOOD STAGE IS S FEET. FPM STAGE WRS F.4 FEET alst To PLo0e singe AFTER nieMIGHT THEN RISING TO MEAR 9 1/2 FT SY BA19REAE... ~ 15EENSON..CT FL008 STAGE 15 12 FEET. FPM STRGE W S 11.2 FEET 7 9'al#. TD Pl.fM4 r.TAGE nFTER MIDHIGHT THEli RISlHE Tn NFAR 13 FT g
.= WSUste RHPD setzte FLh00.St4TEftHT IST10NAL HEATHER SERVICE RlWR FORECAST CENTER. HARTFORD, CT Wie PM RDT tpv 38 1984 e ~ tsUS PLOOb!NG ALONG THE CONNECTICUT ElWR.... k. 909 W M lHGB ARE lH EFFECT FOR THE HOUSRTONIC RIVER IN fMSSACHUSETTS '80NNECTICUts a s THE bESTFIELD RlWR IN tm3SACHUSETTS... THE $$H ELVER IN CONNECTICUT 66. MD THE. CONNECTICUT RIVER IN TTS AND CONNECTICUT .%900 LRMlHGS REtelH lH EFFECT FOR Sr#LL STREAFS IN THE SERKSHIRES (! 45tSSACHUSETTS MD THE NORTHLEST HILLS OF CONNECTICOT. FLOOD bMTCHES a W 4A EFFECT FOR THE REST OF CONNECTICUT AND THE REST OF tmSSACHUBETTS $NtREtt SOUTHEASTERN SECT 10NS. RittS ARE TAKlNG PLACE ALONG THE ISJOR RIVERS IN SOUTHERN HEW 94 THREE T2 FlVE INCHES OF RAlH THROUGHOUT THE CONNECTICUT RIVER IM WILL CROSE THE RIVER TO RISE TO LEVELS NOT SEEH SlHCE THE DEVASTAT-WIE R OCSS OF 1955. SERIOUS FLOODING CAN DE EWECTED ALONG THE CONNECTI- $CtytR THR000HOUT lit LENGTH IN CONNECTICUT MD tmSSACHUSETTS. g 9988941% PLOODING WILL TAKE PLACE ALOHG THE FARMINGTDH RIVER IN E9petECTICUT. MlHOR FLOODlHG WILL TAKE PLACE ALONG THE fERRIr%CK... IWIIWA... M D ASSAGET RIVERS IN EASTERN tmSSACHUSETTS. PLOODlH8 lt NOW OCCURING ALONG THE HOUSATONIC RIVER. maj '. ML MRSONS LlVING MD LDRKING ALONG UMPROTECTED AREAS OF THE - spettflCUT MlWR lH CONNECTICUT AND t995ACHUSETTS ARE STRONGLY WWE9 TO %KE PREPARATIONS TD PROTECT LIFE... Lits.. AND PROPERTY. Its PoLLOWING ARE ARE %RE SPEC lF it PDREC ASTS........ .V ISOSATDMIC ELVER 4 S EAT SARRlHGTUN FLOOD STAGE lt 9 FEET. 1PM STAGE bMS 18.5 FEET. g E!M TD HEAR 12 FEET THURSDAY PDRHING. RECORD FLOOD 1512.1 FEET. ,,4r4RTLOR99VlLLE FLOOD STAGE 18 e FEET. IPM STAGE WS 13.9 FEET. g AlSE TD HEmit is FEET THURSDAY PDENING. '.g W WEMSON FLOOD STAGE 15 12 FEET. IPM STAGE hmS 15.5 FEET.
- v. alm TD NEAN 82 FEET THURSDAY ttHtHING.
3 TICUT RIVER TAGUE CITY FLOOD STAGE 18 28 FEET. M M STAGE W S 34.3 FEET. j Alte to DET1AEH 35 MD de FEET THURSDAY totHING. fWTMNRt919H FLOOD STAGE IS 11i FEE 7. IPH 3TAGE bett MtSSING. .i alSE Te Ntan 1te FEET THURSDAY HoRMING. .e 1 N' alm.WEd FLOOD STAGE IS 9 FEET. IPM STAGE bat 9.4 FEET. j Allt TO DEthEEN !! AND 12 FEET EARLY THURSDAY MTERH00H. 4.- p !NOFitLl FLOOD STAGE IS SG FEET. IPM STAGE hmS 1F.8 FEET. W.' WISE TU BEthEEH St AND 22 FEET EARLY THURSDAY AFTERNOON. We f5M0f980MVILLE
- M STAGE LRS 7.5 FEET.
RISE TD DETbEEN 10 MD !! FEET BY EARLY THURSDAY AFTERN00H. j': Fkson eThat is is FEEf. MM STAGE bas 1s.5 FEET. teRwoR$ .fi* *$198 99 NBAN 88 FEE 7 SY EARLY THUR&44Y AF159N00d -- settaktittel FLDoD STASE IS 8 FEET. MM STAGE bMS F.S FEET. elet it htthEtH 15 AND 15 FEET THURSDAY RFTERH00H. y isSW ttLS RittR- .:.4ESTFitLD FLOOD STAGE It 14 FEET. MM STAGE hftS MISSlHG. i Mffilk HEAR BANKFDLL THROUGH THURSDAY f1NtHING. [p -2 w..
t ..~ q-5W int 4
- 1..
M ~ ~ A tsevict alvut Poeschst esNisR. MAaTFaRs, CT C-MY 881964 T5..T. ......... si................................................ mAftennL m ATMsR BERvlCE MAS DECLARED A FL0ct WmAMIMS FOR THE TitWT AlvsR IN CoMMECTICUT AND MSSACHOSETTE. i w wenWiket htH4tM IN EFFECT FOR THE HoutmTDHic Riv5R IM P9tSSACHU-8 .6 AMs toHNEctlCUT...THE msTFIELD AlvER IN P945tACHUSETTE... AND TON NtVER IN COMMECTICUT4 e istRHtNe FOR teg4LL sTusmNs REtstlNs IN EFFECT IN THE sERusHIREs gemeA&MutETTS AND THE NORTHwST HILLS OF CONMECTICUT. $.s ssassaisosana. 44.a.a... sis............... 4sse.......... "httlCut htVER It RISING IN M488mCHUSETT5 AND CONNECTICUT. THE 15 Asevt ITS FLOQD STAGE IN NORTHERN P9tSSACHUSETTE... AND 5J!LL ,4l81hC94 ITE FLOOD STAGE IN NORTHERM CONNECTICUT bEDHESDAY PORNING. d l TECTED MEAS OF THE COMMECTICUT RIVER IN CONNECTICUT AND PW455A-J WILL EWERIENCE MINOR FLOODING THROUGH EDHESDAY. i 4WtAAT9Mit RIVER 18 ASOYE PLOOD STAGE IN SREAT SARRINGTON...f14 AND i & PERT A80W FLOOD STRGE IN NEW MILFORD..CT AND STEVENSON...CT. FLOODING WILL CONTINUE IN TEEE AREAS EDNESDAY. 3 FLOODlHG WILL CONTINUE ALONG THE ESTFIELD RIVER IN bESTFIELD... g.m CAESTING 14 FOOT ABOYE FLOO'J STACE IN THE EARLY NOUAS. e ' 'DRAWlMtitM RtWtt 18 i P007 btLDW lts PLeon STAGE IN stMasuey...cf b RIt1hd SkthkY. MINGR FLOQBING IS FOtt!BLE EDMESDAY MORNING. 99458 AAt 888884t89 DN W9NetDAY... BRIN 81H6 THE POSeletLi?Y OF
- 'Y M AVT NAINFALL. THE SRQUND IB BTILL 80175 SATURATED.. 80 ANY ITWil0M ERH 98 ElfECTED TD RUM OPF. ALL FERSQHS EFFECTES OY Rf 9tRE AND BTREnts ARE Uitsst to KEEP AsREART OF THE SITWATION...
- I m etMittA MattsNat hanTMsR ssRVics PsRECasT5 AMD. hs44HIN88.
1986A44 Id!LL eE' issues LAtt u sHEspaY MORNIMs. A !Cf y l. '_~Ti. 2 : - " **" ' ' ~ ' ' i l e 6 e 1 l talM - 9 S Y, me.. -.
= ,8 0$F,L*SNFb * (j WOUS00 MHFD 301600 BULLETIN (, FLOOD STATEMENT = NATION AL WE ATHER SERVICE RIVE 3 FOREC AST CENTER, HARTF940, CT .10:40 AM EDT MAY 30 19 8 4 MYed, L 'FLODD WARNINGS REPAIN IN EFFECT FOR THE H0JS ATONIC P1VFR IN
- ASS ACHU-SETTS AND CONNEC' ' 'T... T HE WE STF IEL D RI V ER IN wASSACHUSE'Tt...
(; THE FARNINGTON hl. IN CONNECTICUT A ND THE CONNE TICUT P1VEC IN MASSACHUSETTS AND *0NNECTICUT. (; A FLOOD EARNING F04 56&cL STREAMS REM AINS IN EFFCCT IN THE RE RKSHIF F C 1 0F MASSACHUSETTS AND thE NORTHWEST HILLS OF CONNE TICUT. (; FIVE TO SEVEN INCHES OF R AIN HAVING F ALLEN IN 80RTION9 0F THF BERKSHIRES AND THE h0RTHWEST HILLS CF CONNECTICUT...THIS IS EXPFCTED TO CAUSE MODERATE To SEVERE FLOODING ALONG THE HOUSATONIC RIVER MA%1N. THE (; FARMINGTON RIVER WHICH DID NOT YET RE ACHED FLOOD ST AGr THit "0RNING PI LL
- EXPERIENCE MODER ATE FLOODING L ATE TOD AY AN3 TON 1 git.
(; THE CONNECTICUT RIVER WILL BF EXPFMIE kCING VER Y SIGNIFIC ANT P1Srs... PERHAPS THC' HIGHEST IN OVER A DECADE.... THE FXTENT OF THF RISE WILL DEPEND ON H0'.' MUCH ADDITIONAL RA1H WE RECEIVE DVE4 THF NEXT 24 M nt'a s., L THE CAUSE F3R ALL Tils RAIN IS A VERY SLOW "0VING FR3NT AL 'Y%TE*. THE CENTRAL PORTIONS OF MASSACHUSLTTS AND CDNNECTICUT HAS RCrr!VED BETWEEN 2 AND 4 INCHES OF R AIN...SOME bH AT LOWER A9OUNTS H AS F ALLEN (, IN EASTERN AND COASTAL SECTIONS. (, AN ADDITIONAL ONE TO Td3 INCHES OF R AIN IS POSSI9LE OVEN THE NIXT 24 HOURS. THE NATIONAL WEATHERN SERVICE URGE S THOSES LIVING IN FLDSD PRONE ARE AS TO KEEP ADRE AST OF THE SITUATION AND LISTEN Fnq rueTHro 4, STATEMENTS AND WARNINGS. SPECIFIC FORECASTS T3 FOLLOW.... l () CONNECTICUT RIVER MONTAGUE CITY..MA FLOOD STAGE !$ 28 FEET. 9A4 STAGF WAS ?!.e FT 4; - RISE TO BETWEEN 36 AND 3R FECT CARLY THURSD AY MO*NING. l NORTHAMPTON..MA FLOOD STAGE IS 112 FEFT. 7AM STAGE WA9 MISFING ' (, RISING TO BETWETN 118 TO 119 FEET E ARLY THUR$ DAY MOONING. HOLYOKE..MA FLOOD STAGE IS 9 F EFT. T A" STAGE WAS 7.29 FEET (, RISING TO NEAR 11 FEET BY THURS DAY M3RNING. SPRINGFIELD..MA FLOOD STAGF IS 20 FECT. 9At STAGE WAS 16.1 rrrT (~, RISE TD BETWEEN 17 AND 18 FEET BY T HURSD AY MORNING. 'THOMPSONVILLE..CT 9A* STAGF WAS 6.2 FFET (, RISE TO BETWEEN T AND R FEET BY THUP.SDAY 404NINC.. H44TFotD..CT FLOOD STAGE 15 16 FEET. *A9 STaGF WAS 16.2 FT RISE TO BETWEEN 23 AND 24 FEET BY T HUR SD A Y 90p4140. g, I IMIDDLETOWN..'CY FLOOD ?TAGE IS R FEET. 9AM STAGr WAS r 5 FT (, RISE TO BETWEEk J3 AND 14 FEET 9Y THJRSOAY 9 3 8. I N N G... T H E N CONTINU1NG TO RISE (s MERRIMACK RIVER LOWELL..MA FLOOD ST AGE IS 52 FEET. 9At STAGF WAS 4R.? f,((}f if. RISE TO RETdEEN 51 AND 52 FEET BY THURSDAY 9ORNING. (a _.
= ~ MSFLSHF) ~ 1405a8 MHFI 31SMS ~ ' SCOD STATEPENT stSTIONR WATHER SERVICE RIVER FORECAST CENTER. HARTFORD. CT Weff M EsT tmY 38 1984 .a MOD STATEtENT FOR SOUTHERN HEW ENGLAND...PART I 0F 2 WRY SERIOUS FLOODlHG OH THE N003ATDHIC AND CONNECTICUT RIVERS IH h MTICUT MD tmSSACHUSETTS... 'i y.! d'Al@ER FLOOD bMAHlHG REtMINS IN EFFECT FOR SOUTHERN HEW ENGLAND. z-h.LOOD 4ARRHlHG FOR SmLLER STREAPS REtMlHS IN EFFECT FOR SERKSHIRE thalp-fRRE LIN COUNTIES IN m SSACHUSETTS AND THE NORTHE ST HILLS OF ElpIWCTICUT4 A FLOOD WRTCH FOR SMALLER STREAMB RErm!NS IN EFFECT FOR 4MR REts!NDER OF COHHECTICUT AND t95SACHUSETTS. . IF _ Tiff PmJON RIWRS IN WSTERN tmSSACHUSETTS MD bESTERN COHHECTICUT 'I TINUE TD RISE TD LEVELS NOT SEEN IH PSHY WARS. VERY LOODlHG CAN SE EMPECTED ALONG THE HOUSATDHIC RIVER IN .DSKAT R INGTDH...tm...NEW MILFORD...CT... AND STEWHSON...CT. . 4AY SERIOUS FLOODING HAS SEEN REPORTED IN HEW MILFORD...bHERE A 1SIOPPlHG CENTER HAS LRTER UP TD ITS WlHDOWS. EVRCUATIONS HAVE EH PLACE IN HEU MILFORD MD DOLHSTREAM OF THE STEVENSON DAM. D CLOS! HGS ARE CDtfSH. I -N CD CT! COT RIVER IS IN FLOOD THROUGHOUT ITS LENGTH IN SOUTHERH M W ENGLAND. PMHY AREAS WILL SEE RIVER LEVELS NOT APPROACHED $1HCE $ FLOOPS OF 1955. SEVERE FLOODlHG CAN SE EMPECTED. m Mit FMMINGTDH RIVER WILL CONTINUE TD RISE THROUGHOUT THE NIGHT.... ING PCDERATE FLDCDlHG. W,SEtJ4ERE IN SOUTHERN HEU ENGLAND...MlHOR FLOODlHG CAH SE EMPECTED
- y. THE CHICOPEE AND bESTFIELD RIVERS IN ESTERH fMSSACHUSETTS... AND
. OH, THE PERRIrmCK..;HASHUA... AND ASSRSET AlWRS IN EASTERN tm. ' ~ h9EE STDtti SYSTEM THAT CONTINUES TD CAUSE PRECIPITATIDH HAS DELIVERED "JN EXCESS OF d AND 5 INCHES THROUGHOUT THE CONNECTICUT RIVER VALLEY... . 4RM) APSOHTS REACHING EIGHT INCHES IN THE HOUSATDHIC RIVER VALLEY. EASTERM SECTIONS OF PMSSACHUSETTS... CONNECTICUT... AND RHODE ISLAND WRVE RECE!VED CONSIDERA8LY LESS. xi A h PERSONS LIVING AND LDRKING ALONG UNPROTECTED AREAS OF THE ' 1 CONNECTICUT MD HOUSATONIC RIVERS ARE STROHGLY URGED TD rmKE .9tfPARAi!0HS TD PROTECT LIFE... Lits... AND PROPIRTY. [.'IF,RLOOS!HGISENCOUNTERED...ITISWISETOFOLLOWAFEWRULES... 90 NOT GO HEAR RISING RIVERS UNLSSE WU PSJST. WU tmY INTERFERE y 4!11W PbOOD FISHT!HG EFFORTS...MD Wu t9Y SE INJURED. e g$qtMSTUSETHERIVERSFORRECREATIONALPURPOSES...HO je thA0W TDOR kHILbREH TD PLAY HEAR N!S!HG RIVERS AND STRERfS. h*!50 Nef TitY til DRlVE ALONG FLOODED ROADS AND BRIDGES. THEY tmY HAVE A GEEH letSHE) 007. .,n M40EY THE litt1HOCTIONS OF WOR LOCAL POLICE AND CIVIL DEFENSE $l$UTHORATitt. THER PESSASE WILL FOLLOW WITH SPECIFIC FORECAST 3. g...a m,-.- Gid-5 44 e
~ 4 IS0SFLSHFD j$se KMFD Stedes .15 00D STATErENT {4pT10HAL WATHER SERVICE river FORECAST CENTER. HARTFORD. CT 3hthS3 PM EDT tmY 30 1984 OPS STATErEHt...PART 2 0F 2 E, POL (Ohl!NG ME ARE PERE SPEC IF IC F0MEC ASTS........ [4000AfDHlC RIVER Y 4AEAT SARRtHGTDH FLDOD STAGE IS 9 FEET. FPM STAGE bRS 18.5 FT l {.gt,RFSE TD HEAR 12 FT THURSDAY FORHING. RECORD FLOOD IS 12.1 FT [y BRM.ORDSVILLE FLOOD STAGE IS S FEET. FPM STAGE WAS 15.3 FT j , WISE TD BETWEN 15 1.1 AND 18 FT THURSDAY PORHlHG. v9. ' I i I TEVENS0'E ' FLOOD STAGE IS 12 FEET. FPM STAGE bRS 22.4 FT ~ h RISE TO BETWEN 22 1/2 AND 23 FT THURSDAY FORNING. e l g4MECTICUTRIVER -.s'f9HTRGUE CITY FLOOD STAGE IS 20 FEET. TPM STAGE blRS 36.0 FT . ) RISE TO BETEEN 38 AND 39 FT BY THURSDAY AFTERHOOH MORTHHerFTDH FLOOD STAGE IS 112 FEET. SPM STAGE WRS 1tF.3 FT F RISE TD HEAR 128 FT THURSDAY PORHING. . W .)f. MOLWKE FLOOD STAGE IS S FEET.'FPM STAGE bRS MISSlHG ? Y.. RISE TU SETE EN 11 AND 12 FT BY EARLY THORSDAY RFTERHOON. l SPRINGFIELD FLOOD STAGE IS 28 FEET. TPM STAGE WRS 15.5 FT 'jr. RISE TO DETEEN 21 AND 22 FT EARLY THURSDAY AFTERNDON. TMBffSOHVILLE FPM STAGE WAS 3.1 FT RlSE TD BETEEH 9 1/2 MHD 18 FT EMLY THURSDAY RFTERH00H. , vel l '*j!MARTFORD FLOOD STAGE IS 15 FEET. FPM STAGE IJtS 28.5 FT ft RISE TD HEAR 28 FT EMLY THU PN. 29 TD 38 FT FRIDAY FORNING. 1 1 'tMIDDLETDbH FLOOD STAGE IS O FEET. TPM STAGE WAS e7 n p RISE TO 15 TD 15 FT THUR PM. RISE TO 19 FT FRIDAY FERNING. o TFIELD RIVER ( ' 4ESTFIELS FLOOD STAGE IS 14 FEET. TPM STAGE lets 14.5 FT SIM 15 AIEAR 15 TO 18i FT THURSDAY FWRNINE. m 2 htMINGTDHRIVER "I 54f50URY FLOOD STAGE IS 12 FEET. TPM STAGE bRS 13.4 FT l l RISE TO 15 TO 15 FT SY EMLY THURSDAY RFTERH00H. l j r., L M T river .: ' '. 984WMD FLOOD STAGE l$ 5 FEET. FPM STAGE bMS MISSING $c- , RISE TO HEM E FT THURSDAY AFTERH00H. l M IfWICK RIVER Ut'E.alELL FLOOD STAGE 15 52 FEET. FPM STAGE lets 50.2 FT I alSE TO MEAR 53 FT EARLY THultSDAY AFTERHOOH s FLOOD STME 19'39 FEETi-FPM STAGE WR$ MISSlHG i yW"i lqEM El 1/2 FT EMLT THURSDAY AFTERH00H. RISE.it FLOOD STAGE 18 15 FEET. FPM STAGE WRS MISSlHG ~ j y.i.'aggNERHILL J Rist Tti letAR 141/2 Ft THURSDAY AFTERH00H. 1 A s! mSsMun StVER j 4. SeST PEPPERELL FLOOD STAGE IS S FEET. FPM STAGE lAtt 5.7 FT ' $p.. tiet 75 FLOOD STASE TDHlft.. TD IS TD 11 FT THURSDAY PM N!.xT===E met u inutD THuRnAY M=HiHG (g@t, mm-
~- 400980 KHFD EllFOS $DLLETlH ADDD WRNING 14RT10HAL WEATHER SERVICE RIVER FORECAST CENTER.' HARTFORD. CT Stite FN EDT ISY 31 1984 "f"h y, ~ PERT Tkn DF tESSAGE Def FOLLOWING ARE ARE FORE SPECIFIC FORECASTS........ G $$USATONIC A!VER N SREAT BARRINGTON FLOOD STAGE IS 9 FEET. FAN STAGE kstS 18.9 FEET. i Y.$ REfS!H HEAR !! FEET THROUGH FRIDAY FORNING. IhSA%.DRDSV!LLEFLOOD STAGE IS S FEET. FAM STAGE W S 15 8 FEET. RlSE TD IS 1/2 TD If FEET LATE TDHIGHT. , p STEVENSON FLOOD STAGE IS 12 FEET. TAM STAGE WAS 21.7 FEEL'. J ?' RISE TO HEAR 23 FEET TDHIGHT. " R. ECT! GUT RI%ER @{.reMTAGUE CITY FLOOD STAGE IS 28 FEET. FAM STAGE WAS 3F.1 FEET. RISE TO MEAR 48 FEET LATE TDHIGHT. j g' TMORTHHAffTON FLOOD STAGE IS 112 FEET. FAN STAGE WR$ MISSING. -j'f' RISE TU HEAR 121 FEET LATE TDHIGHT. m jMOLTDKE FLOOD STAGE IS 9 FEET. 7AM STAGE L54S 18.1 FEET. ?..; RISE TD HEAR 12 FEET EARLY FRIDAY FORNING. N ),'DPRINGFlELD FLOOD STAGE IS 28 FEET. TAM STAGE WAS 21.2 FEET. RISE TD 22 TO 23 FEET EARLY FRIDAY FORHING. k'i 4 % TM0ffSOHV!LLE TAM STAGE WRS 3.9 FEET. RISE TD HERR 12 FEET EARLY FRIDAY FORHING. MARTFORD FLOOD STAGE IS IS FEET. 7AM STAGE WRS 24.5 FEET. RISE TU HERR 38 FT FRIDRY 99RHING. TD HEAR 31 FEET SATURDAY PORH. l ~ MISDLETOLN FLOOD STAGE IS 8 FEET. FAM STAGE WAS 13.4 FEET. RISE TD _1S TD 28 FEET FRIDAY FORNING. HEAR 21 FEET SATURDAY FORH. i k WSTFIELD RIVER .' ESTF IELD FLOOD STAGE IS 14 FEET. TAM STAGE hs45 12.2 FEET. ',{;; ESt5tlH MSIE SANKFULL THROUGH FRIDAY tORHlHG. ~ J N TONESWR % SOFESURY FLD0D STAGE IS 12 FEET. FRM ETAGE' MLLL FEET. $.c RISE TD 18 1/2 FEET FRIDAY PORHING. ACKSMNE RIVER f FLOOD STAGE IS S FEET. FAN STAGE h5tS 5.2 FEET. f yI 'lD87)eRIDGE T...1t!SE TD BETLEEN O AND 5 FEET LATE TDHIGHT. 3 'WONS3CKET FLOOD STAGE IS 9 FEET. FAM STAGE bftS 5.5 FEET. 9 Y RISE TO FLD0D STAGE LATE TDHIGHT. i.T. li4NTIC RIVER .f.i 900RWICH FLOOD STAGE IS S FEET. 7AM STAGE WRS MISSING. 2. ", RISE TO MERR S FEET BY THIS EVEHING. f '..I $p WILLit91HTic TUCKET RIVER FLOOD STAGE IS 13 FEET. FRM STAGE bMS 10.1 FEET. Oy RISE TO MERR 12 FEET BY LRTE TDHIGHT. CHARLES E1VER FLOOD STAGE IS 4 FEET. FAN STAGE buts 2.42 FEET. ' DOVER RISE TO FLD0D STAGE ON FRIDAY. SLOW RISE THEREAFTER.
l [ . ~. amule8 KMFD 341588 AWLLETIM 1 ALD0D bMRMING I 484TIONAL LERTHER SERVICE RIWR FORECAST CENTER HARTFORD, CT rS2 AN EDT MY 31 1984
- p' P
..w.h ART ONE OF TLD PESSAGES.... '# M R FLOOD hmRHINGS HAVE BEEN ISSUED FOR THE YANTIC RIVER IN E$NNECTICUT, NASHUA,. ASSABET, PERRitmCK RIVER IH tmSSACHUSETTS RHD THE SL4CKSTONE 2H C:10DE 15. WER FLOCD LRRHINGS RErm!H EFFECT FOR THE COHHECTICUT, FARMINGTON, '188USATONIC, CHICAPEE AND PAWTUCKET RlWR.
- .q M,0CD LMRH!kGS ret 91H lH EFFECT FOR REST OF CONNECTICUT, AND FOR ALL SQT SOUTHEASTEM t995ACHUSETTS.
~.A A quLOOD IMTCH Rtl%!NS lH EFFECT ELSEIJ4ERE lH SOUTHERN HEW ENGLAND 43R:EPT CAPE CDD. fyW 1RItIOUS FLOODlHG 15 TRKlHG PLACE ALONG THE HOUSAT0 Hic AND THE CONNECTICUT AtVER THIS FORNING. CONDIT!DHS WILL BEC0fE PCRE SERIOUS ALONG THE _ T.$HNECTICut AS THE RIWR CONTINUES ll) RISE. . t.s WE FLOW FORECASTED ALONG THE CONNECTICUT RIVER ARE C0ffARABLE TO 4WAT OF THE FLOOD OF 1955. THOSE PEOPLE LIV!HG ALOHG THE RIVER 4 SENSITIVE MONPROTECTED ARERS ARE URGED TO KEEP ASREAST OF THE SITUATION AND PREPARE TO TAKE ACTIDH IF HECESSARY. ~ OMS THE HOUSATOHIC, FLOWS ARE ALREADY AT THEIR HIGHEST LEVELS li!HCE THE FLOOD OF 1955. THE RIWR IS NOT Riti!NG AT AS GREAT A RATE AS LATE WSTERDAY m.fT WILL CONTINUE TO RISE ANOTHER FOOT OR 50 BEFORE CRESTING LATE TODAY 9Vt' TON!GHT. I W fARMlHGTDH RIWR LMS AT IS FEET THl$ tCRHING AND STILL RISING. TEWE RIWR WILL RISE TO LEVELS APPROACH!HG THAT OF JUNE OF 1982. k it!WERS IN ERSTERN PMSSACHUSETTS. EASTERN CONNECTICUT AND RHODE SSLAND ARE ALSD BEGlHNING TO SHOW LARGE RISES. HEAR BRHKFULL OR OVERFLOW "T.0HDITIONS ALREADY EXIST FOR THE YANTIC RlWR IN CONNECi! CUT, THE ASSABET 6 PERRlrRCK RIVER IN resSACHUSETTS, PAWTUCKET R!WR IH RHODE ISLAND AND 3 (3N NUfEROUS OTHER SimLLER RIVERS AND STREAr15. AN ADDITIONAL TLD e,, puma vr NMIM CRM WE amrst. imp uvan TMr. nam Is ru as muuma. $$$1TIMAk SAlMPAkk WILL CAU$E $1BMIF184NT A00 DINS iM SOtt 0F M ppsewsumMmununani, .DilW THE LRtt ad HOURS SOUTHERN HEW ENGLAND HAS RECEIVED BETLEEN ( >d"44 TB 3.8 IHCHES OF RA!H. THE AREAS RECEIVINS THE HIGHEST AtSUNTS b4ERE IN THE HSRTHERM AND CENTRAL PGRTIDHE OF tmSSACHUSETT3 AND l pliSteECTICUt. THESE WILL RECE!W ASBITIONAL RAIN TODAY. I r ~. l IC FORECAttl WILL DE FOUMB IN PART ThB 0F TWI6 PESSAGE TO FOLLOW [ 5 l C4JLFCH4.H I mi _.... _ ww ~ t-UlN 4
l l 15DSFLSHFD 6 804 KHFD 010508 FJ.000 8'TAtEERT" i 14ATIOH4L LEATHER SEltVICE RlWR FORECAST CENTER. HARTFORD. CT 44'114 $ EDT iSY 31 1984 , :y.: s - %',.FLOCD STRTErENT FOR SOUTHERN HEW ENGLAND......................... i 4 y .....tStJOR FLOODlHG ENPECTED DH THE COHHECTICUT RIVER..... c.Il 4tWR FLOOD LRRMINGS ARE STILL IN EFFECT FOR THE HASHUA, ASSABET, 4RD fERRIrmCK RIVER IH ISSSACHUSETTS AND THE SLACKSTONE IH RHODE IS. i.? 4440 RIVER FLOOD ImRRNINGS REfSIH IN EFFECT FOR THE CONNECTICUT, qSATONIC, FARMlHGTON, CHICOPEE, AND PAWTUCKET RIVER.
- h. EMRHINGS REr%!H IN EFFECT FOR REST OF CONNECTICUT, t995ACHUSETTS.
W RIOUS FLOODING 15 TAKlHG PLACE ALONG THE H005ATOHic AND THE CONNECTICUT 11VER THIS EVENING. CONDIT10HS WILL SECDPE EWH FORE SERIOUS ALONG THE 1:9NMECTICUT AS THE RIVER CONT! HUES TO RISE. NOT 51HCE AUGUST 1955 HAVE E SEEN SUCH A FLOOD. ALL AFFECTED PEOPLE SHOULD RELATE TO THE HIGH 45tTER f9RKS THAT !HUNDATED THE CONNECTICUT RlWR VALLEY THAT WAR IF AT MLL POSSIBLE. CONTACT LOCAL AUTHORITIES IF HELP IS HEEDED. WlE MATIONAL LEATHER SERVICE hMRHS ALL INTERESTED PEOPLE TO W E PROTECT!YE ACTIDH FOR LIVES AND ALSO PROPERTY. KEEP ABREAST OF WIS $17UATIDH AND PREPARE TO TAKE ACTIDH IF HECESSARY. a _iaLOHC THE HOUSATONIC, FLOLE ARE AT 1NEIR HIGHEST LEVELS SlHCE THE TL:IID OF 1955. THE RIVER HAS CRESTED THIS EVENING AND WILL SE FALLING 'IELDi.t.Y THROUGH TONIGHT. , -..m. iun u. a _; ;,7 a n: c :: := ::: ::: G;;;i :::::d. g 41Wil Wikk ElBE ti ktyths APPROACHING THAT OF JUNE OF 1983. t alWR IN Editt4H mienCHWSETT9I, BARTSRM CONH8CTICUT AND RHODE ' M MlE ALl0 BHDulNQ LARGE R!BES. HEAR 9ANKFULL OR OWRFLOW NQlS(T10HB EHlSt DH THE YANTIC RIVER IN CONNECTICUT.THE ASSABET WD WERRll$tCK AlVER IH ISSSACHOSETTS, PAWTUCKET RIVER IN RHODE ISLAND p 1M HuftROUS OTHER St%LLER RIVERB AND STREArt. MRE SMLY SCOD HELB 15 THAT THE PER$1 STENT RA!HS THIS PAST BEEK HAVE "ShlALLY tilVED 007 0F FCET OF SOUTHERM HEW EHELAND. l k 9 SPECIFIC FORECASTS WILL BE FOUND IN PART TLD OF THIS PESSAGE TO FOLLOW. AaraACAJPVCH/TM WM-R l
{ ESSFLSHFD ~. 54gutes KHFD 018488 PC),00D STATENHT
- (Ap$TIONAL bEATHER SERVICE RIWR FORECAST CENTER. H6'TFORD, CT pg 21 RM EDT m Y 31 1984 MIT TkEl DF PESSAGE
'g!. FOLLOUING ARE ARE PCRE SPECIFIC FORECASTS........ i .] USATDHIC RlWR h GREAT SARRlHGTON FLOOD STAGE IS S FEET. FPM STAGE bRS 18.9 FEET. .j NAS CRESTED. FALL TD NEAR 18 FEET BY FRIDAY PORNING. .f f,.SAWORDSVILLE FLOOD STAGE IS 9 FEET. TPM STAGE LRS 15.8 FEET. MAS CRESTED. SEGlH FALLING TD MEAR 15 FEET FRIDAY FORHING. i I i... STEWHSON FLOOD STAGE IS 12 FEET. FPM STAGE WAS 21.8 FEET. 1.9. 1 MAS CRESTED. BEGlH FALLING TD MEAR 21 FEET FRIDAY FORHING. MCTICUT RIWR d ICHTAGUE CITY FLOOD STAGE IS 28 FEET. TPM ETAGE hmS 38.1 FEET. I M: rem!N HERR CURRENT LEWLS THROUGH FRIDAY FORNING. ( f?MORTNHAmTON FLOOD STAGE IS 112 FEET. FPM STAGE WAS MISSING. ] h REmlH NEAR CURRENT LEWLS THROUGH FRIDAY t9RHlHG. MOLWKE FLOOD STAGE IS S FEET. FPM STAGE WAS MISSlHG. f rem!H MEAR CURRENT LEVELS THROUGH FRIDAY FORHING 1,' ] lCPRINGFIELD FLOOD STAGE IS 28 FEET. FPM STAGE bMS 22.5 FEET. g,:. MOW AT CREST. rem!H NEAR 22 1/2 FEET THROUGH FRIDAY FORHING. ; h TH0tPSOHVILLE FPM STAGE LMS 18.4 FEET.' j i p#, NOW HEAR CREST. RErft!N HEAR 18 t/2 FEET THROUGH FRIDAY FORHING. MARTFORD FLOOD STAGE IS is FEET. FPM STAGE LMS 28.2 FEET. RISE TD NEAR 38 FT. BY FRIDAY PORNING. CREST 38 TO 31 FT FRIDAY EVE. ,f** lMIDDLET0bH FLOOD STAGE IS S FEET. FPM STAGE bMS 17.1 FEET. e' . J M. RISE TD IS TD 28 FT FRIDAY PORHING. CREST HERR 21 FT EARLY SATURDAY. N., y'iESTFIELD TFIELD RIVER FLOOD STAGE IS 14 FEET. FPM STAGE LMS 12.0 FEET. ret 94tM HERR CURRENT LEVELS THROUGH FRIDAY IORNING. @T41tS8URY !HGTDH A!WR [ FLOOD STAGE IS 12 FEET. FPM STAGE LRS 15.8 FEET. i i GEST MAR 15 t/2 FEET FRIDAY PORNING. ?'.: $1JACKSTDHE RIVER M MORTHORIDGE FLOOD STAGE IS S FEET. SPM STAGE lett 8.3* FEET. h{ MOW HEAR CREST. SLOW FALL WEGlHNING LATER TDMIGHT. NH $ 30HSOCKET FLOOD STAGE IS S FEET. TPM STAGE WAS 5.0 FEET. CREST MEAR 18 FEET FRIDAY FORHit8G. K lc RIVER i ( WINORWICH. FLOOD STAGE IS S FEET. FPM STAGE WAS f*ISSING. y ;$d RIVER HAS CRESTED WITH ONLY MlHOR FLOODlHG UNDERWRY TDHIGHT.
- 4
$1UCKETRIVER 4 4 HILLIPStNT!C FLDOD STAGE 15 13 FEET. FPM STAGE 6mS 10.8 FEET. I W CREST HEAR 12 FEET LATE FRIDAY tcRMING. l M ES MlVER < D0VER FLOOD STAGE IS 4 FEET. FPM STAGE bRS MIS $1HG. RISE TO BANKFULL AND REtRIN THERE FOR SEVERAL DAYS. y[yNS la.Aed RiwR oh t9WMARD FLOOD STAGE IS 5 FEET. FPM STAGE WAS MISS1HG. I
- r
.',I.4.p- $_.* g,1 KMPt 811680 J t STillftttHT 1 % m950seALelAATHER SERVICE RlWR FORECAST CENTER. HARTFO t ~ M 89f..JUN st 19e4 f. 4, J ~,. .m. [ gpswam.s. s-Ply 40 lMa tH SodtHERH HEU ENGLAND IShN Rt@%T10F S TO 9 INCHES OVER THE FAST SEVERAL DAW HAVE CAUSED 8 3 FLOODlHG ALONG THE FWIJOR STREArs IN SOUTHERH HEU ENGLRHD. TOMMECTICdt RlVER HAS CRESTCD IN PytSSRCHUSETTB, REACHING THE HIGHEST WP98ES SINCE THE HURRICAME FLOCD OF SEPTET 9ER 1938. PCHTAGUE CITY CRESTED THIS FLDOD kWl' 4S et FEET WILE IT REACHED 22.T FEET AT SPRINGFIELD, f94 844M18E8 TD SLIGHTLY EMCEED THE AUGUST 1955 FLOOD IN THE CONNECTICUT PART PW4XIttJM VRLUES IN 1955 bERE 38.5 FEET AT HARTFORD AND 20.4 i M.1DE AlVER. $7 MIDDLETDW.
- c.. )
cercTs n o unosamw cercrrn i nst rurwr.c. nwn sent e m aa y arcern. gaa.4 FEET AT GAYLORDSVILLE AND is.S FEET r, n t 'l988 ISSIM AT tR347 antalM87981 AMD 84%#488= 4441LE STEVENSON IRS ]IJST SELQU THE 1955 RECORD. g NR CAEttED At StP58URY EMLY THIS FORNING AT 16.2 FEET SQUALING THE FL909 0F JUNE OF 1982. M LL0hi!MG ARE ARE tcRE SPECIFIC FORECASTS........ p.. IWMIC RIVER 9-44 SEAT SMRlHSTOH FLOOD STASE IS S FEET. FAM STAGE buts 10.4 FEET. , 9Leid FALL TD HERR 9 t/2 FEET SATURDAY PORHING. W VLORD9VILLE FLOOD STAGE IS S FEET. FAH STAGE buts 15.8 FEET. SLOW FALL TO HEAR 14 FEET SATURDAY FORHING. ..[OfftB0H FLOOD STAGE 18 12 FEET. FAN STAGE WRS 19.5 FEET. M FALL TD MEAR if 1/2 FEET SATURDAY tCRHING. k f dHECTICUT RIVER FLOOD STAGE IS 28 IEET. FAN STAGE Efts 36.5 FEET. I e MTAGUE CITY . FALL TD HERR 33 FEET SATURDAY FORHING. L gIORTHNAlfTDH FLOOD STAGE IS 112 FEET. FAN STAGE WR$ MISSING. gg78L 70 HEAT ilt FEET SATuirDAY tcRHINE. c., NN'9EE 00D STAGE IS 9 FEET. FAM STESE heint MISSlHer .- PRLL 79 9 1/2 70 18 FEET SATURDAY FORHING. EinGFIELD FLOOD STAGE IS 29 FEET. FAM STAGE LutS 22.5 FEET. FALL TO 28 TD 21 FEET SATURDAY PORNING. ..i-TAM. ETAGE.4AS -18.3. FEET. SLpd PEk it MBAR S 78tf SATURDAY rORnina. jpWB FLOOD STASE 18 16 FEET. FAN STAGE WS 38.3 FEET. 2457 M84R 81 FRET SARLY THl4 EVENING. 179444 FLOOD STAGE IS S FEET. FAM STASE buts 19.F FEET. geSet 31 7e et FEET ameLY SATURDAY reRHINS. nGTDH RIVER SareSURT FLOOD STRGE 18 it FEET. FAM STAGE butt 15.1 FEET. HAS tmEttED. PALL to HERA id FEET SATURDAY MDRHIHSa @/ (/ 6 ) 7 1 ll' -- STDHE RlVER
- T
-=> man muar in 8 n gy, y g g g g FEET.
- __ wn e -- Aguses KHFD 020308 400DdT*.TEENT, WATIONAL WATHER SERVICE R!WR FORECAST CENTER. HARTFORD. CT
- y..s 45 p EDT JUN O! 1984 J@SSD STATENHT FOR SO'JTHERH HEW ENGLAND...PART ! 0F 2
.THE CONNECTICUT RIVER IS CRESTlHE lH HARTFORD... CONNECTICUT ~ D nmRHINGS rem!N IN EFFECT FOR THE HOUSATDHIC AND CONNECTICUT RS IN MSSACHUSETTS AND CONNECTICUT...THE FARMINGTON RIVER IN $4NNECTICUT...THE NRR ISCK...NASHUA... ASSABET... AND CHICOPEE RIERS 141 MSSACHUSETTS... AND THE BLACKSTONE RIVER IN RHODE ISLAND. W p CONNECTICUT RIVER IS HOU AT CREST IN THE HARTFORD...CT AREA.. 0VER W ff ABOVE ITS FLOOD STAGE. THE RlWR WILL CREST IN THE MIDDLETOW... .ST. AREA OH SATURDAY 14 FT A80VE ITS FLOOD STAGE. THISE LEVELS SURPASS WOSE SET DURING THE 1955 FLOODS...AND ARE THE HIGHEST SIHCE 1938. W1WR STAGES LOULD HAVE BEEN PSJCH HIGHER WITHOUT THE EXISTENCE OF THE $TLDRK OF FLOOD CONTROL DAMS BUILT BY THE ARrff CORPS OF ENGINEERS. { -p:. %WE HOUSATONIC AND FARMlHGTON RIVERS HAVE CRESTED IH NSSACHUSETTS AND g" THESE RIVERS THROUGH THE E EKEND.HECTICUT...BUT 'REMIH AT VERY HIGH LEVELS. FLO W M; M OR FLOCDING CONTINUES ALONG THE N RRImCK...HASNUA...AND ASSABET 41WR$ IN EASTERN m...THE CHICOPEE RlWR IN ESTERN m... AND THE KACKETONE CIWR IN RHODE ISLAND. ~ apIPROTECTED AREAS OF THE CONNECTICUT RHD HOUSATONIC RIVER CONTINUE TO SUFFER SEVERE FLOOD dam GES. THE NATIONAL GUARD HAS BEEH CALLED DUT
- IN HEW HILFORD...CT ALONG THE HOUSATDHIC RIVER AND HEAR CR0f'lJELL.i.CT 4LONG THE CONNECTICUT RIVER. NNY ROADS RHD HIGHl.RYS HAVE BEEN SCOSED... INCLUDING PORTIONS OF ROUTE 9 AND ROUTE 66 IN MIDDLETOW.
httNY MONS AND BUSINESSES HAVE BEEN FLOODED... AND EVACUATIONS HAVE TAKEH MELI 4CE. AGRICULTURAL DAmGES...PARTICULARLY IN THE CONNECTICUT RIVER MEY...ARE EXTEN!i!VE. FLOODING DCCURS IN YOUR C0fftJHITY...!T IS WISE TO FOLLOW A FEW PIterr_LE stuLES... Y'
- w. - m i au== mu m o mi um.m wu rm i. wu mi in urm
~ ptTM Fke#I Plenfine tPromis...nHe Y0u my at IMJuRao. ' g N0f Ulf TMt name Poe escatafl0NAL PuRPGSES...MOR SHOULD Y00 gM TOON CHILDREN TO PLAY HEAR FLOODED RIVERS AND STREAts. let TRY t0 DRIVE ALOHG PLO99ED ROADS AND BRIDGES. THEY MY H4W !,s.jM netSHED SWt.
- w
,%,(effMORit!ES. W EY THE lHSTRUCTIDMS OF Y904 LOCAL POLICE AMD CIVIL DEFENSE THER ISSSAGE L211 FOLLOW WITH SPECIFIC STAGE FORECASTS. M ' -- l 1 yc+a.
SOSFLSHFD 4GUSGS KHFD 025308 l _ ECOD STATErfHT - l -4pT10HAL IKATHER SERVICE RIVER FORECAST CENTER. HARTFORD. CT [14'46 FM EDT JUN011984_Qg* iEDOD STATEtENT.a.PART 2 0F 2 i it.t FOLLOWlHG RRE ARE FORE SPECIFIC FORECASTS........ SATDMIC RIVER A ; GREAT BARRINGTON FLOOD STAGE IS S FEET. FPM STAGE WS 9,7 FT FALL TD HERR 9 FT SATURDAY PORHING -- SAM.ORDSVILLE FLOOD STAGE IS S FEET. 7PM STAGE ims 14.4 FT 7s, FALL TO HEAR 14 FT SY SATURDAY PORHING. STEVENSON FLOOD STAGE IS 12 FEET. TPM STAGE WRS 10.4 FT
- g FALL TD HEAR !? I/2 FT BY BATURDAY FOtHING.
s 89HMECTICUT RlVER gfCHTAGUECITY FLOOD STAGE IS 28 FEET. FPr1 STAGE WS 35.1 FT 1 FALL TO HERR 33 1/2 FT SY SATURDAY fSRH1HG. HORTHNAffTDH FLOOD STAGE IS 112 FEET. TPr1 STAGE W S MISSlHG FALL TO HEAR 116 FT SY SATURDAY PORHING. h gp-HOLYDKE FLOOD STAGE IS 9 FEET. TPM STAGE WRS filSS!HG FALL TD BETbEEN 9 1/2 AND 18 FT SY SATURDAY PORH1HG. g Y SPRINGFIELD FLOOD STAGE IS 28 FEET. SPr1 STAGE W S 21.9 FT .k FALL TO HEAR 28 t/2 FT BY SATURDAY PORHING. b@)TH0ffSOHVILLE 7PM STAGE W S 9.S FT 2. FALL TD HEAR 9 FT 8Y SATURDAY PORHING. + HARTFORD FLOOD STAGE 15 16 FEET. 18PM STAGE W S 31.1 FT. fe i HOW AT CREST. LITTLE CHANGE OVERHIGHT. j(.:: MIDDLET0kN P FLOOD STAGE IS 8 FEET.10Pf1 STAGE WAS 21.8 FT d CAEST NEAR 21 1/2 FT SATURDAY PORHufG. !"==== =%T9H -R 94ER 3 jf.! S trWBURY FLOOD STAGE IS 12 FEET. TPt1 STAGE WS 15.3 FT d FALL TO MEAR 14 FT BY SATURDAY PORHIllG. 'd WCKSTDHE RlWR ?'bCONSOCKET FLOOD STAGE IS S FEET. TPM STAGE WS filSS!HG N FALL TD HEAR S FT BY SATURDAY PORNING. y i $ $ TUCKET RIVER
- f FLOOD STAGE IS 13 FEET. SPM STAGE WAS 9.7 FT
].j WILLitmHTIC FALL TO HEAR S 1/2 FT BY SATURDAY ftRNING. l m /, LES RIVER i 'DOYER FLOOD STAGE IS 4 FEET. TPM STAGE WRS 4.9 FT MlHOR FLOODING HEXT FEW DAW. 2 ABET RlVER I fMWARD FLOOD STAGE IS S FEET. SPM STAGE LRS 5.7 FT l ....] FALL TO HEAR 5 1/2 FT SY SATURDAY PORHING. V ptPRitmCK AlVER .iLOWELL FLOOD STAGE IS 52 FEET. EPM STAGE WS 53.4 FT N f*Dif HERR CREST. FALL TO HEAR 53 FT BY SATURDAY PORHING. ~ LA4JtENCE FLOOD STAGE IS 28 FEET. TPr1 STAGE WS f11SSING l MOW HEAR CREST. FALL TO HEAR 23 1/2 FT BY SATURDAY FORNING. HAVERHILL FLOOD STAGE IS 15 FEET. TPM STAGE lAS filSS!HG. [ h yo@CHlHGCREST. LITTLE CHANGE OWRHIGHT. o _u.
' s.5FLSHFD . JS00 KHFD 021800 C, *;30D STATEMENT .-IIONAL JEATHER SERVICE KIVER F3 HEC AST CENTER, HARTFORD, CT l2:48 PM EDT JUN 02 1984 IST OF TWO PARTS ~ ( FLOOD WARNINGS CONTINUE IN SOU THER N Nrw EN3L A*'O 'INFALL AH3dNTS OF I/4 TO I 1/2 INCHr$ HAVE rALL',N CURINC THr La*T (;- - H3JRS I N S0JTHEIN NEW [NGLAND. THIS RAIN HAS CLUSES SOME OF THr 4LL RIVERS AND STREAMS IN SOUTHERN NE W ENGLAND TO RISE. HnWEVrc. TAE CONNECTICUT RIVER WHICH CRESTED L ATE LAST NIGiT IN HARTFOR3 AN3 3' AT CREST IN MIDDLCT0dN WILL ONLY EXPERIENCE A SLowrP RECrf.SION A% (- 'ONNESEQUENCE OF THIS RAIN. THE HOUSATONIC RIVE 1 WHICH HAS ALiO IN RECEDING OVER THE L AST 24 HOURS WILL RECEDE AT A SLoJER # ATE (- 2'.3 VILL E XPERIENCE MINOR FLUCTUA TIONS DVER THE N:XT 24 HSUPS.
- L30D WARNINGS ARE NOW ISSUED FOR THE Y ANTIC #IVr4 19 EatTER"
(- (NECTICJT.THE HLACKSTONE RIVER IN
- ASS ACHUSETTi AND RHODE l'.AND, AND PAWTUXET R1VFR IN RH3DE IRLAN".
t ' 1303 WARNINGS REMAIN IN EFFECT FOR T HE F OLLOWING RIVERS: CONNECTICUT THE FARMINGTON R I V ER AT SIMSPURY (; THE HrUSATONIC R I V rR AT GAYLOR3SVILLE AND STEVENSON , ( THE CONNECTICUT RIVER FOR TH! EN'IFE LENrTH 4ASSACHJSETTS THE CONNECTICUT RIVER FOR THE ENTIRr LENGT9 f THE CHARLES RIVER AT D3VEP THE MERRIdACK RIVER F3R THF ENTIRE LENGTH THE ASS ABET AND N ASHU A RIVERS IN v.E. MAFS. 4 THE NEPONSET *IVED IN ' ASTERN 4Atr. THE CHICOPEE 9IVE; IN CEMTRAL Mast. .E CONNECTICUT RIVER CRESTED AT-51.1 FEE T L ATE FRID AY NICHT AT H AS T t 34 3, 1 l .'a ! CH !$ THE THIRD HIGHEST 3F RECORD. A CREST AT MIDDLETnWN IS OrrucFING i IT NOON TODAY OF JJST JNDER 21.5 FECT - ALSO Tit-T41R3 HIGHff.T OF 8FC313. RH3DE ISLA1D THE PAJTUXET RIVEk IS EXPERIENCINi "IN3R FLonDING AS 1r . TE MORh!NG. THE RIVER WILL RISE A N O THE R SEVERAL FEET THIS Ar T E R 3 r k AN7
- RLY TONIGHT.
, g I RAIN AND SH0JEA ACTIVITY FORECAST FOR THE NEri SEVERAL HOUR 9 It fr2EPTE0 T1 HAVE THE M3ST CFFECT ON THE SMALLER STREAHS AN) BD00K%. THE Lie".Ct THE
- IERSHED THE LESS THE EFFECT WILL 3E.
SECAUSE 0 THE REE000 FLOWF 19 T'I CONNECTICUT, THE RAIN THAT FALLS IN THE NEXT SEVE*AL HOUn! SHOULP 4 AVE
- 'TTLE Ok NO EFFECT ON THr AIVER.
S L OWLY FALLING STAGrS Apr FYoTCTTP TS g '.LDJ THE CREST. g TCIFIC r0 RECASTS JILL BE ISSUED IN PART 2. &l%
<)SFLSHFD (;, s )US00 KHFD 021900 CoR r.000 STATEMENT CORRECTr3 .LTIONAL WEATHEM SERVICE RIVER FORECAST CFNTro. HARTFSDD, CT g 01: 00 PM EDT JUN 02 1984 3g{ 'ECOND CF TWO MESSAGEe...C09RECTED F*R M 11NGFIELO...... 1 1E F OLL 0 dI N G AR E M3 R E S P E C I F I C F ORE C AS T S............ (- g-3NNECTICUT RIVER MONTAGJE CITY..MA FLOOD STAGF IS 28 FEET. 7At STAGE sas tp.m FT VEGY SLDV FALL TO NEAR 32 1/2 F1 BY SUNOAY *3*NING. NnRTHAPPTON..MA FLOOD STAGE IS 11? FEET. 7A* STanE VAs MISSINc. VERY SLOW FALL T3 NEAR 115 FE E T SUNO A Y MORVING. HOLYOKE..MA FLOOD STAGF I S 9 F FET. 7 AM STAGr WAS 10.7 FT VE8Y SLOW FALL YO NEAR 10 AND 101/? FECT if SUN 9AY MO"NING. b SPRINGrIEL3..MA FLOOD STAGF IS 20 FEET. 108 STAGF WAe P0.1 rf VERY SLOW FALL TO B E 1.* E F N 19 1/ 2 AND 20 FEE T EY RUNDAY "0 D *'I N C. L TH3MPS3NVILLE..CT 7A1 Star,E PAC 9.9 FT VERY SLOW FALL TO NEAP P FT eV 93N3AY MS A NI M G. L HARTFORD..CT FLOOD STAGE IS 16 FEET. 7A* STAGE WAe 'O.o rT CRESTED 10PM J Uf:E 1 AT 31.1 FT. VERY Slow rAL.L TO o[AF ?.C FFET (, BY SUNDAY MOR11hG. Cnd m MIDDLETowN..CT FLOOD STA;E le R FEET. 7AM STAgr vae 21.3 rT f, N0i NCAR CREST... REMAIN STEADY THROUGH C CH OF IMF OAT... J B E Glid VERY SLO. FALL TONIGHT. ~ (; ERRIMACK MlbER LDJELL..MA FLOOD STA3E I* 52 FEET. 7A* ST4GE uAS 53.2 FT BEGIN TO RISE AGAIN TO DETJEEN 53 1/2 ANS 54 Frri ?Y SUA3aY
- n's.
C LAWRENCE..MA FLOOD STAGE Ie 23 FEET. 7AM tTAGF Wat u!SSING A BEGIN TO RISE AGAlz? T O 0 2 T a ?.* F E E T 9 Y SUN 3AY *0RNING. C HAVERHILL..MA FLOOD stair I*, 15 rErT. 749 eVAar V A e, " l e. t I N r BEGIN T3 RISE AGAIN TD NEAR 16 FEET 3Y SUNDtY "SRNING. C '3NCORD RI VER LO4 ELL MA 7A" rT AGF W AS MIeSIN1 (, RIST SLIGHTLY OVER BANKFULL 9Y SUNDAY "S3NING. ASHUA RIVER (, EAST PEPPERELL..MA FLOOO STAGI I S H r FE T. 7 A" STAGE WAS 11.C FrFT RISE TO BETWEEN 12 FEET AND 12 1/2 FEET BY SUNrAY
- S R $' I Nn.
( '4ICOPEE RIVER INDIAN ORCHARD..MA FLOOD STAGE IS 12 F rE T. 7AM STACf VAS 17 1% FT REPAIN NEAR 1? FEET TH40 UGH SUNDAY M3RNING. l. ARMINGTON RIVER SI"SBURY..CT FLOOD STAGE IS 12 FErf. 7AM STAnr VAe 14.4 FT (; REMAIN BETWEEN 14 AND 14 1/2 FEET TIL SUNSAf MSONINC. '4E NEAT MESSAGE WILL BE ISSUL D S ATUR DAY EVENINS. ERFC/CH/b4/rJL/LJM
- aQF;LsH'F2 = ~ ^ '
- WbusesKHFDBII486
!E 00D STATEtENT -14AT10HAL bEATHER SERVICE RIVER FORECAST CENTER, HARTFORD. CT JUN 82 1894 lJin37PHEDT
- COND OF TLD ffSSAGES...
I 'E FOLLou!HG ARE TORE SPECIFIC FORECASTS............ SATONIC RIVER GR. 3RRRINGTON.t1A FLOOD STAGE IS 9 FEET. TPM STAGE WAS 3.3 FT 2 -? - - FALL TD BETLEEN 7 1/2 AND 8 FT SUNDAY tORHING. &5 [' 94\\0RDSVILLE..CT FLOOD STAGE IS B FEET. FPM STAGE LMS 12.9 FT l FALL TO HEAR 12 1/2 FT SUNDAY FORHING. FLOOD STAGE IS 12 FEET. TPM STAGE WS 15.5 FT hlSTEVENSON..CT j FALL TD HEAR 15 Ft SUNDAY FORHING. N 7 ~f ECTICUT RIVER f0HTAGUE CITY..tm FLOOD STAIE 15 29 FEET. TPtt STAGE bails 31.5 FT
- *4 VERY SLOW FALL TD HEAR 31 FT BY_EMBAT iSAnM&--
T9' jg! MORTHAffTDH..tm FLOOD STAGE IS 112 FEET. 7Pf1 STAGE WS MISSING. G YERY SLOW FALL TD HEAR 1141/2 FEET SUNDAY IORNING. M W,:HOLYDKE..tS FLOOD STAGE IS 9 FEET. TPM STAGE WRS f1SG -?, VEdY SLOW FALL TD HERR 9 FEET BY SUNDAY FORHING. 3.-l
- c.
SPRINGFIELD..fm FLOOD STAGE IS 28 FEET. TPM STAGE has 19.9 FT VERY, GLOW FALL TD HERR 19 FEET BY SUNDAY tORNING. - a.: N
- dj TH0!?SOHVILLE..CT TPM STAGE has 8.1 FT VERY SLOW FALL TD MEAR 7 1/2 FT BY SUNDAY FORHING.
%y HARTFORD..CT FLCOD STAGE IS 16 FEET. TPM STAGE LAS 38.4 FT CRESTED 18PM JUNE 1 AT 31.1 FT. VERY SLOW FALL TD MEAR 29 t/2 [.j FEET 8t* SUHDAY FORHING. 'd IDDLET01.H..CT FLOOD STAGE 15 8 FEET. 7PM STAGF WAS 21.1 FT CRESTED TDDAY AT 21.3 FEET. VERY SLOW FALL TD HEAR 20 1/2 l 1g-l FEET BY SUNDAY FORNIHG. y t' h. 4 RRitSCK RIVER , ? LDELL..fm FLOOD STAGE IS 52 FEET. TPM STAGE hmS 52.5 FT yf. LITTLE CHANGE IN RIVER LEVELS T0HITE. ( 7 LAkREHCE..fm FLOOD STAGE IS 28 FEET. TPM ETAGE bMS MISS!HG l q,j LITTLE CHANGE IH RIVER LEVELS TONITE. MAVERHILL..tM FLOOD STAGE IS 15 FEET. 7PM STAGE WRS MISSING LITTLE CHANGE IN RIVER LEVELS TDHITE.
- CONCORD RIVER *
- ,. t L0 BELL tm FPM STAGE WRS MISSlHG.
_ U; RISE SLIGHTLY OVER BANKFULL SY SUNDAY FORHING.
- m <
h'SHUARIVER p8 EAST PEPfERELL..t1A FLOOD STAGE IS S FEET. TPM STAGE WRS 11.7 FEET l LITTLE CHANGE lH RIVER LEVELS TDHITE. ]. '"C#1COPEE RIVER ,.p. lHDIAH ORCHARD..tm FLOOD STAGE IS 12 FEET. TPt1 STAGE WRS 12.2 FT ?? LITTLE CHANGE IN RIViR LEVELS TDHITE. v', FptM!HGTDH RIVER fff = ^ S it1EBURY..CT FLOOD STAGE IS 12 FECT. TAri STAGE LRS 13.8 FT (#( a s.1 alTTLE..C%t$F._IN RIWE.LEWI.$ TDHITE.....
AppendixB Northeast Utilities Evaluation for Stage-Discharge Relation at the Connecticut Yankee Site O e t
r. CONNECTICUT YANKEE ATOMIC POWER COMPANV B E R L I N. CONNECTICUT P o Box 270 etARTFoRD. CoNNECTsCUT 06141-0270 Titt e t sc3=s-sooc July 1,1985 Docket No. 50-213 B11399 Director of Nuclear Reactor Regulation Attn: Mr. John A. Zwolinski, Chief Operating Reactors Branch #5 U. S. Nuclear Regulatory Commission Washington, D. C. 20535 Gentlemen: Haddam Neck Plant SEP Topic Il-3.B, Flooding Potential and Protection Requirements On May 30,1985, the Staff requested that Connecticut Yankee Atomic Power Company (CYAPCO) provide a rating curve of river elevation vs. flow for the United States Geological Survey (USGS) gage on the Connecticut River at Bodkin Rock. On June 5,1985 we advised the Staff that this information had been requested from the USGS and would be forwarded to the Staff upon receipt. Attached is a copy of the information received from the USGS. Note that USGS has indicated that the stage elevation is affected by the tidal effects up to elevation 8.0 feet Mean Sea Level (MSL). We trust the Staff will find this information satisfactory. If you have additional questions, please contact us. Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY . F. 0,JL
- 3. F. OpekW Senior Vice President cc:
Mr. Don Chery, USNRC
l Docket No. 50-213 Attachment SEP Topic II-3.B. Flooding Potential and Protection Requirements Connecticut River Rating Table for Bodkin Rock d I k l i l i i l l June,1985 n-- -e----, a,-. ,-n-., -r e-.,---r--n .mr - r -, r-e
s [
- c o
o': o' o- @' o*r.o. o': t '4 ..Ja n o c: o": el c . o; 8:: o' o' o. 8:: @t. t @' o - e:. g:I .,cn,~ t oo o: o:
- o: o: o 6 e t a2 ;
e , =1 o o: o o: . e: e so: so: so: e: e so m: oe in: et es:
- o. m. e.: cn.
o
- : e.
o: s 1-i <g
- m. )..
o: o! o of of of c: . m y
- .3 ~. e o of 8i ei o o: 888i s
o: o: o o: c: o: c: u o ' 8 oi 8i 8: 3 c: o: E 8 o o; s 1 C. o e: = e e: w: o: e: o 2 J ! m m:: e: m
- n..e :
o
- ew
- ::
I.2a c: e : e u co: c cs o -: e: m: g cn; m: o. o:: o o: c: ~ e: -.: : e.e e: c-e mo .o: o: o o-n: o .o.<- : .o.o.<~ : o ,.g G,,,_g u so ~,* e; .4 s g gy a. s. a.
- s.. s.
s. s. a. a. s. a. a. a. a. s. a. a. a. a. is. c. &.: j' Z.. .O 4 C} N_ o.r M. g. g.
- 4. =u
. o: o: o o:
- 2 4
o: j!
- ,r. o:
on
- o: o o:
e :: so.! so.:! e., e.:.: m.:f E! c: of 8 e c: g Q t= oi 8 E: o: o: c: o oo o so so; e:i of of 8! co. co ;so;! o: So 8.: o o e .as ; , g i ej so so; so; 1 e. !8 . so:. et. e. so.: a...e 1 3 b e! R 8!8!8!Si8!8!81 'Si8 8 8 8! 8 Si Si Si s !! ei w: ? *j 6 ew:: e: e: N: c: .e: e: c. m a: a e. eN c m: n: 4: an: e:
- ' '.e e : e: w:
- o o: e=: so os c:
m: so : so: est n e - so: so: so: so: l c en: e: e: e .e. : - m: sol eo m' e: ch; os as ch as m: cn: en: c
- o.,
t o,s'l.,21=n? .c o y a. s. a. a. e. a. a. a. a. a. a. s. a. a. e. a. a. a. a.
- a. 4 s.
- n
- u. !.
= o .o a n o: E o:. c. g. a i c. et. i o o. . e: o.: c:. os El ai e joe , E:: E:: E 58: E:: o =] 6 e-4 en, ~E. w: o c: c: c: o:
- A
~. s ele a: c: e s
- rj r-; e-; e-; e-;
c: E e e: e-j e-;.e : e c.; e; r. . g.- ? 8!8 8 8! 8;i 8i 8i 8i 8! 8 L 8' 8. 8 8.( 8 8! S 8' 8i. n!8:! k..o-o E _C g c: W e-e; in in: ew e ci .j ew! eue :i n"' e in ei e eg n o e-e so! so ,od o o so,, m co io a. in -2 .3.. j w: e
- ew o
E o.: e; r et.cn! m;j. r*: e-o
- e e-.
es e, r=.g #3 c-r3 rg e ; B
- e f
I w s eg eg m: 7,. 4:, ) r,i r. a. a. a. s. a. a. a.
- a. s. e a.
a. a. e. a. a. a. a a. a + t - s t p u c: ? C eo b.g u:: l=g; e gi g! 8: g 8; 8! g. .c : ~ .=g g ,-v. .E m: gi g! 8! g; g gi gi gi gi. g g; gi g;i !.g .2 : i 5g g: o m. et e e ei e ~! ~: ~i ~ ! ~ i e : c-i ~; ~; ~ ~ ~ ~; ~i ~ - g.4 m: ~ s ? }5 $ c$ 8' 58 Si El 8! [:! 8 8, g. . 8'8!8'gi8!8! 3 :% i o
- 88. n.c l
n: e-: n: e: m: ew: e n Eg 3 t
- n art e' e-: e m: on o
-: ew n ne - n en: e e.: e,e - en e: w
- e ; n:
o.: c c.: v v, net. in, e: n.: n.:
- c:
- c.:
- n: n. e; e
.I e.: e., e. e. e. o:. o:.e. e: oy E,! iy ,3 a. s. a. a. s. a. a. a. s. s. a. a. a. e. s. a. a. a. s. W e: y e. m5 si
- 6. -
cl e .e : z e- .c. v:
- Ef ci Bi 8i 8i,8i 8!,8! e!,8
,8 ',8i 8,. 8! e8!,8! 8i 8' 8 8i 8i! p 1 1 e,8. e l e : e 8 o e i i
- c e.
o i_.,.o : o:
- o ot e et
- e. e e
- e. e3 _.ou !
.3 2 g *4 4,es : 3 o !~: E B.i88! Si 8! 8i 8i 8i g!] ! Ei 8: 8 g c8 8! 8i 8; g:i J n e,. I .e e-( (3.: 3 A an: 4 2 L;l Dd: e. n: cn:.n: ' n; c: r w -: c-: nu -: e-s n; m: n s c. c.; e .e es: o oo- .,w: e we
- e: e :- e=
e-: n .gm v-c.: e. c.: c:. c:. c:.e g
- u n
n: .,, c. - : p g c. c.:.c ; irw. erv. en, an.: e en. im. - c.o t/0L*u ! '"'. }s fa a* s" a* s*
- a a*
a a* a a a* e a a* a* a* a* i
- s
- g
- d. u :
- .4E' e
( '* 3 : e l I c. n
- m.k-I gCi i
i j i .e-- m. c. ;.. O-l 6 l l i { i I ~ ': u: i -i i i C N* g 1 ?m j 1 '"), j i 4 I ** *x* t. e i I "0 : 5" l 1 l 1 1 < s*- i. j l;l, l 1
- 1. I 3
6 i i 4.: i I ) e4 o i. II T I. I. I. I. I. I. I. . k _p o :.c : f ff s.
- \\
N K ,g O : e.n El ( 4 :: ,i as
- si
( E., ,ow. .c 3 .i .I .k - ! '"' v
- a
} l E.;;. ** 1 i %o = a6. g I ,g O. :: .a. l es g 1 in 3 D l g 6 i i
- =.:.>
e e t l g* ,an ? 5 t ,I ., si .I 'f, ,c e j a...k. l
- m]
cs 7 s. s. a. a. e. 3 s. a. a. s. a. a. a. a. a. a. e. a. a. s. .c a. c e
- =;e*
u ac
- ..i 6
u en
- a o
== -c. "l3 r
'[ o. ' !- oC 2la d I ig!-.. Si
- 0
~i e. - l 1 i l _ l m-m- i I]l~ C. s ' 7: + g t-es c. i - <if 7 'i i i i ~3-2-i _.t'- m a 3 T ei E
- N I
i i t %s. i, i M. .5 >. :: :: J s .y g d__j.! i I l I k e ,54;,,~3 g s. a a. e. 3 a. a.
- a. a. s e.
a.
- s.. s.
a. a. a. a.
- 3. Q.
g a _b . 4 a i
- -a o
~ ~ .gc;< g c- .h. $ h i' I C: S h ~_..ae/'
- O 4
g- = = * *
- g e
m: 3 Qi i i 1lll: '*i b@v;:M i i C; I It l-l i @ :i- ! :i = Q o,,,i '. ).I,,f, y3 . 3 R. S. 5 5 2 3
- 4. y5' 2
R. A. 8 8 8 2 8 8 =.* c.t I$ 0: iC.c. ! l l l l-l l'D i. Im. o;. l: Il
- l
'C: i c -t
- .: w i
.a -lsi 2 o.- ..s gi. ei c: o ci c c: ci o e. c: %i **: 5"' i eu ei t:: h i y c: c:: E_6-8ll:: 9 C c. t,, s ososo g 4: mS:.: c.-. 87 eo r c-. c.r? en.7 c ; j *c:::, c:.o-q ei ,e,.. w Ng e W,: e ;t;,: 5:: c: 6 c: c: s c4 t es;: em Cg.s
- r-e e
=-
- .,g,4:
<en: g i 3:J' $ tt .g,,.; y:,;,; s c c -, -. e..c,,,,: .e: 2> w: e ": ,s e g N e.: e ",,- l ' ': ' g y g n.
- V C N 44 N
a i 2., gr y : a. .a. a. e. a. e. a. a.
- a.. s a.
a. a. a. a. a. a. a, a. E a . wa .n g 3 y r u s u gI $ 8 ' Ei 8 ! 8:. ~! "O. ~ f *f.6 O E-C C c c o o { =I' ej kj l*[ g e-
==: -: C m C s. o C c " ' '. " * " i "": "i,,.; O. ll" ~.l r
- 5. :::
c o o ~~ l j j $ k 'y 6e f . 3 8:i 8 8: g; .c. s.i .g.8;: c:i gi g. -} T. r cw ,.: e-i ,f ,c. e i s'8 o 2o c: m so: *. c s c: b
- e: r
- a ti. ! ,a:. s*. gg U-N m:.e m: e: c: T'. e. t. 9". M se - l 8 :i c ; _ w g e- .U es m y t= c f g N ^; ^ hi Ni N _.,w o_.! i_,y :..s_i e-j c-j c_: 5 .s. c .e :.A...s.. g. a. w 4 O; s; ),:1....... s. e. o. g 5 . ji CJ! O yi ed wm b l E ,g ,.. g i Bg i i o 8: 81 gl o; R' 8! 8 o! 8! 8! 8! E! o! 8 Ri 8l cw: 8 . 8! . _k _* 8 f m; o i 8: 5: c: o
- c:-o: c: c: 8: o 5;. 81 i
>u e r%- g
- jO s: e-ec:
.m .er.-m .I cid m e: e; so: os
- cu E:i "
- ! *!. e:i m:
$ mi. e el e:j m:-. ei.e ei *so! m
- ^::
e o e ei mi mi e 3 . N. 2 s. _. 1J J s. a. a. e. a e. z. a. a. a. a. a. a. e. a. a. a. a. a. j -' i . yf e:: 4.r* es i . s a 6 u* !!I g c: o: c: c: er c: c; , o q 'l s ; ca. c: c: e. o: o o o c: c: oJ o. , es:. .oe.c .c . -c.' o. " a :.' e. ee os: os: m: i - : u-c l ,, e e e U* S-e 8 C: Q. G W. W W. 8:. G.; n e: n:o 5:; 5:. 8:- o: Q Q. O Q. S o. o-o 8: c ~: -: o
- c:
t gN m: :l" I m: e: r: e C - -: N m e en: @ N: 80: O. 8"'t 8"'t: .."t 8 4
- I
.e".l:*.e='t: Oj I. .f*t:..ft .I"'.t a.C.* :er:.r. a e e e w; ev:e - '.e .w, .c, .t.* :.C.q'..C.": ..e.:..c. ;.n. n. . M. e a .=g
==:
- , s.
i, s..........,,... _.............. .g a. ci e I. g i 4 y I g g.. g "a h ek O C C. C. C. C.
- O. o G.
C O. .I c. O. o. O. o . c: o. c; o. l i g o c: o
- c:.c:
4 c: o o ' in
- .o o
e .c c: c: c: .E 1 g e. art c: n. m:
- e: r*
d -4
- es: et r=: c: l -
I* ar m ew .e:.. m:: .e. :
- e N:
c: - n m e. m - e; N c: c: m; o: -: a .c 2 e .=:. ew N m: m: I /. N..- ; . c.v. f ew ew 4, ew.;: -; w: rw: e.w. : j.:: e.v.
- l 3
- m
'E j . 8 8 8 8 8 8. 3 E S. S. S. 2 8 8 8 8 8 2 S. S.
- e..
'4 = m g .e we
t r EVALUATION OF CONNECTICUT RIVER FLOOD DATA TO ESTABLISH AN ESTIMATED STAGE-DISCHARGE CURVE FOR THE CONNECTICUT RIVER AT THE CONNECTICUT YANKEE SITE BACKGROUND The Connecticut Yankee (Haddam Neck) Nuclear Power Plant is located in the town of Haddam Neck, Connecticut, along side the east bank of the Connecticut River, approximately 19.5 miles up river from its confluence with Long Island Sound. The power plant presently adheres to a set of procedures for actions that must be taken upon receiving flood warning from CONVEX, the U.S. Geological Survey (USGS) River Forecasting Center, or upon observation of river level approaching site grade level (21.0 feet mean sea level). PURPOSE l The purpose of the evaluation is to establish both an estimated stage-discharge curve for the Connecticut River at Connecticut Yankee (CY) and an estimated relationship between flow and travel time from upstream points to CY. DISCUSSION OF RESULTS Evaluation of the historical (Reference 1) and theoretical flood i data (Reference 2) for the Connecticut River between. Thompsonville and Connecticut Yankee plant has resulted in the following exhibits. 1. Exhibit 1: Comparison of peak flows for the Connecticut River (based on historical flood data). 2. Exhibit 2: Approximate time of travel from various gaging stations to CY. 3. Exhibit 3: Estimated stage-discharge curve for Connecticut River at CY (based on historical flood data). Review of the historical flood data (Reference 1) indicates that there is a large flood plain effect (significant river channel storage) at the Hartford and Middletown locations. Consequently, the time of travel of peak river flows from Bartford to CY increases significantly for flows between 150,000 and 275,000 cfs representing the range when the flood plain effect is the greatest. .--___,e
Using the information from Exhibits 1 and 1 (based on USGS historical flood data) and Reference 3, the estimated stage-discharge curve for the Connecticut River at CY was prepared (Exhibit 3). It is important to note, however, that the data used in these evaluations to prepare the curve is not conclusive since,according to USGS, storm pattern and intensity variations can have a significant effect on the results. REFERENCES 1. United States Geological Survey Flood Data for the March 1936, September 1938, April 1982 and May-June 1984 storms. 2. Technical Evaluation Report--Quabbin Dam Failure Flooding Consequences at Haddam Neck Plant, prepared by Franklin Research Center, August 25, 1983. 3. Hydrograph.of Connecticut River at Connecticut Yankee (May-June 1984 flood). D
- 1. -
GENERATION CIVIL ENGINEERING NORTHEAST UTILITIES SERVICE COMPANY December 1984 i l 1
eJ l- 'I o a., ...~~--o -,.3 D. - ~' \\ g \\ A- \\ g t 8.s 2 u: ( l F-IQ ILJ G .g.... j g:- _g - sp O O f**.* .t \\ )' b. L~.1 ~ l-tj Q Q s- \\ j IP /.. l.t i o r G. F-- o o i h 1 U. C C \\ l q g "1
- s. -
t* D g U .~ %.. j g] k.A .- - c,, ;< w g t, c. \\ .a W I,o .4 u g, \\ l I~1 F' 4 4 O g.) rv . _I ..J
- r, L
i li 1 t. 1IJ ~ L - g \\ gj I e _3 .i, i o 5 g ~uo j 6 l 'I ' 3 '.1 \\\\y F-4 a,, o s -r s O \\ \\, W c-C .N - p u_ s-r p s\\ G -p C 4 . s. % }w s
- o.. s 1 k
.g E-
- <; C
'y <1 ~ [ C' $\\ _3 .a eg, - ts. j \\ (*' O
- t. -
l V ... -.m.. 'k U. ~~4 U ..o l 7 O lk 'v f h C %g. Dj t' k R ~ ex O .k.. c -p ^ \\ r 4 C \\ ~ U J 7q'1TT1) e i n s j i s i s j TTTv] i i s e j li s u j i v i s ] v i v i) s e s s ) si si j :: l TTTT ~ O u *s is* * (,' U"' C.* If f G ID G b2 O ID C' LD Cs f. la (J C.e l' - Us r-J s r. gn cJ Ge t-U> t<. n
- t. -
t.i ed ra r-e cd .-e a .- 4 4 (0001 x Sd3) SNDI1VIS WV38.LSNM00.LY MD 13 W3d EXHIBIT i
o O c;. l l l Ve \\ t i \\ \\ I g g ut, 9.- 'j c"4 .- - u.* --y .-1,- ) ,_J Q s' G G A I' I l. r. l .. c. ISA .) U-v- 4. ~o g >-j rs g 3 ,e ce.. t? \\ \\ . 2, r-- \\ l J \\ LL =- g n-Q e Lil h. .q...< tj _. O .? I r \\ l i _J .3: \\ (1-w., G' >A O \\ T Lt .x F-A, ist LJJ g .i ~_~ O LLI e ~ 2 O tr J
- d r.
I t' ' O A 0- - - r 'L' t1 p o% \\ uy. I-y O I-
- h..
-,.. - -c C C IL 2 LLI O .s. e I II I-- U c. t. I-- I rt' E H % A' <I _J \\ U s l- - l-LLI O I f- ^ o <T. G Z n. I E LU 2., 1 R._ '.E O. '
- 2 s.
o o O V -- \\ J _J _I X \\ O U LA-Li. LL. [2J .4..- 9 y, s 9 di 4> d l JIIEB)IIII]3553]B353]3333)IIIIJ3333JIIII(IIII(' 883(833I~ [s i G LT.1 C. - 10 O LD G' Lf n G Lf.' G try tr,
- t v
tr> l) of CJ -4 s-4 (BH) 33)ttMA in3I.L33NNO3 01 13Nd81 :10 3101 l EXHIBIT 2
O O ti, --._._._..........L.' t _.._...--_Y...._E 1
- e..
\\ t t \\ \\ ._.:.. g _c-c. O d \\ [ t.u - <I \\ .a f.n 1 3 ,,3 p - ic. Lt. c 7 C.J U.. i c u2 O d I I.l.1 .0 .2 f".J 14 o e_ .e w a G.:[ . _ _ _ _ _.... _ _ _..._._. _ _....... e., ge i- ' i c: 4 g H .-* a u w D aw _ \\ U i I -l . c k y m t- 'D ^ G U C 8J (gf p,I .....g... .f.i .s g,., \\ i-I f.; t-1 .T. gyj g s O T-c.. z d \\ W .0 ee h 5. LA' g l-- N e - o a \\ ~ 0 . 'aJ O id 4 h<..__s ~3 s p p i.T \\ - ' O g .I g g i 'e 4 I ie Le m H ,g 4 13. C s, a T.
- E
~ (.r.^ 4 q g. t.ij r.%_ l-g l, Cl X ...,3 is ..._g.. g tij oa tt l l . i, ' i T"T~J i i i jTi il I""'TTT~pT T a l i u l~T**s a i . ;i is t r.* ri tr. y, at ..J _a TIA31 V3S N'13tl 3A08'd.L 33.3 EXHIBIT 3
i APPENDIX C CONVEX MEMORANDA
(- CONVEX==.D=r'~ ~~~
- .~
k CONNECTICUT VALLEY ELECTRIC EXCHANGE P.O. sOE 3.. .........e...... June 24, 1982 System Operations Supervisors and To: System Switching Supervisors C. W. Deegan @ From: Dissemination of Weather Bulletin Information
Subject:
This memo supersedes A. Pedersen's memo of 11/16/72 on the subject information. Weather Bulletin information received at CONVEX will be passed on as soon as practical, if it contains any l of the following items: g 1. Lightning Storms. 2. Sustained high winds - 30 m.p.h. or more. - 3. Sleet or freezing rain. 4. Heavy rain - 2" or more. 5. Heavy snow - 6" or more. 6. Higher than normal tides. When in doubt - pass it on. The following should be ac,cified: 1. NEPEX Pool Coordinator 2. One of the following: C. W. Deegan Ext. 222 Meriden 237-8532 A. Pedersen . Ext. 224 Farmington 673-5142 E. M. Vipler Ext. 238 West Hartford 233-7815 (
e j l ~ CONVEX ~ i I CONN 2CTICUT VAtLEY ILECTRIC EXCHANGE { P.o. soa 345 SouitliNGioN, CoNNICTICUT o6489 July 20, 1983 To: ' System Operations Supervisors and System Switching Supervisors From: C. W. Deegan
Subject:
Dissemination of National Weather Service Hurricane Advisories This memo supersedes C. W. Deegan's memo of 9-12-77 on the subject information. Whenever a National Weather Servic'e Hurricane Advisory is received at CONVEX that indicates a hurricane or severe tropical storm is located above Latitude 30*N and West of Longitude 70*W, the System Operations Supervisor will notify R f & u.uk M -0. T. Z.tl u during normal working hours or the Brush Hill Customer Service Center af ter normal working hours. At any time that the storm goes above Latitude 35'N and West of Longitude 70*W. the System Operations Supervisor vill relay the latest information to the appropriate persons tO in accordance with Section I of the Notification Book. In addition to the above, when the storm has gone above Latitude 35'N and West of Longitude 70*W the System Operations Supervisor will relay the latest information to the following: 1 1. Millstone Station I Operator 2. Millstone Station II Operator 3. Conn. Yankee operator Note: Millstone Operator and/or Conn. Yankee Operator will be calling for the latest update every two hours. I 4. NUSCO Production Dept. Burricane Task Force. 1 Note: When a hurricane poses an imuninent danger to ( ' ~ ~ Connecticut, the NUSCO Production Department will activate a Hurricane Task Force which will man a location in Berlin around the clock., The System Operations Supervisor will be notified when staffing i takes place. Call W. D. Reichelt Berlin Ext. 5849 , to contact the Hurricane Taka Forca. /~ DWL:cac b} cc: R. F. Webler R. A. Reckert J. Y. Opeka i t
r. During office hours - R.". eL1=r 8 C.7Lqe Lu k lExi f fI 3. a. fl( b. Outside office hours - Brush Hill Customer Service Center 4. The following Generating Station Operators: Millstone 15G Northfield Mt. 16R Cobble Mt. 18F Devon 7R Norwalk Harbor 6J M ntville 4J o Rocky River 12Y W. Springfield 8C Conn. Yankee 12R Middletown SA Mt. Tom 22C 5. The following receive weather information similar to ours and it should normally only be necessary to verify that they have received the information. H.W.P. Co. Riverside Operator H.C.&E Operator U.I. Co. Distribution Dispatcher - Skiff St. Central Region Dispatch - Sheldon St. Eastern Region Dispatch - Madison O worther= nesi ni 9 tch - r 11 =4 ( Southern Region Dispatch - Stamford Western Region Dispatch - Waterbury Western Mass. Region Dispatch - Brush Hill DWL:cac cc: R.F. Webler O ( -}}