Errata to 850820 Application for Amends to Licenses NPF-9 & NPF-17,revising Tech Spec 3.6.1.2 Re Allowed Containment Leakage Rate.Proposed Change to Spec 3.6.1.2a.2 Re Reduced Pressure Testing Should Be Disregarded
ML20137Q797
Person / Time
Site: McGuire, Mcguire  
Issue date: 01/28/1986
From: Tucker H
DUKE POWER CO.
To: Harold Denton, Youngblood B
Office of Nuclear Reactor Regulation
Shared Package
ML20137Q801 List:
References
TAC-59696, TAC-59697, TAC-60710, TAC-60711, NUDOCS 8602070024
Download: ML20137Q797 (1)


Text

-

/

8

+

Duxic Pownen GOMi%NY l'.O.HOX Wilfl0 Cll AMI.OrrE. N.C. 2152 4 2 IIAL 15. Tl*CKEH tuternowr.

== = emeetnes,

(70 4) ura-.4Mt

" " " ~ " " "

January 28, 1986 Mr. Harold R. Denton, Director Office of Reac. tor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

B.J. Youngblood, Director PWR Project Directorate No. 4-1 l

Subject:

McGuire Nucicar Station Docket Nos. 50-369 and 50-370 l

Technical Specification Amendment.

Containment integrated Leak Rate

Dear Mr. Denton:

By letter dated August 20, 1985, Duke Power requested a change to Techr.ical

-Specification 3.6.1.2 concerning the allowed containment leakage rate. The proposed change affected 3.6.1.2a.l. and 3.6.1.2a.2 for allowed L and L,

respectively, increasing each value by 50%.

Since the justification and safety analysis in support of the proposed change addressed only the full pressure testing and leakage, Duke Power requests that the proposed change to Specification 3.6.1.2a.2 concerning reduced pressure testing be disre-garded as indicated on the attached page and only 3.6.1.2a.1 concerning full pressure testing be pursued. As McGuire has not conducted a reduced pressure test, has no data on such a test, and no plans to conduct a reduced pressure test, there is no basis for this changing the specifica-tion as it relates to reduced pressure testing.

As this request supplements an earlier submittal, no fees are required.

Picase feel free to contact us if you require additional information.

Very truly yours,

-S y

Hal B. Tucker 8602070024 860128 JBD/j gm PDR ADOCK 05000369 P