.- I.
- ~
APR 2 01972 Docket No. 50-341 MR
!' f l
pt?i $
"DTh.l;-r$
Mr. Falter J. McCarthy, Jr.
gcFN
-t Manager for Engineering-Wuclear s
The Detroit Edison Company 2000 Second Avenue
' CQ m
{ sto
~
Detroit, Michigan 48226 u
l
Dear Mr. McCarthy:
IIer.iecro of the Atomic Energy Condssion's regulatory staff uct with Mr. Tom f
- organ, Trustcc of the Frenchtown Tounship board, and Fr. Frank Kuron of Neuport, Michigan on April 3,1971, and with repre-sentatives of the Detroit Edison Cocpany on April 7, 1971, at the
.Cormission's tethesda, Paryland Offices to discuss environmental natters associated with quarrying operations at the Enrico Ferni Atomic rouer Plant site.
In order.that un raf assess the environcental imaet of the pumping of trater and of blasting at the onnite quarry,3 please provide the Division of Radiological and Environuental Protection (REP) uith the follouing inforration for our continuing environmental review; and for preparation of the Final Environnental Statement for the Enrico Fcrni Atomic Pouer Plant:
A.
Please provido detailed inforre. tion for ucils in the vicinity of the Fermi--2 site.
1.
Include caps showing the locations and total numbers of wells in cach 45* coupass sector within 1 mile, 5 nile, and 10 c:ile radii.
- 2., for all wella for which date are available provide a.
locations, depths of vells and unter levcis (referenced to a cocnon datua if possihic), and b.
datca of censurcacuts.
3.
Detail inforration on uclls concerning uhich complaints have been rcccived including any follow-up actions thercon taken or planned.
{
4.
Substantiate, for crampic by current-incter naasurements at appropriate locations, that the areas of high ground nater l
l tucjnorthendofltLcquarryhfvcbeenscalpd.
l ilow at APK z s 19/2.
f./
l 8601230349 851219
//
C[J l
l l
,m.
l.
hr. Walter J. McCarthy, Jr. 5.
Provide previous, current and anticipated future. pump sizes, flow rates and durations of flow in quarrying and in denatering construction sitesjincluding details on discharge locations.
6.
Provide information, such as data from horings near the quarry, to indicate the types of groundwater strata that might be encountered in future quarrying. What further lateral and vertical excavation of the quarry is planned for the completion of Fermi-2 or for future construction?
B.
Discuss alternatives to onsite quarrying and provide a cost-benefit analysis betueen these alternatives and past, current and future quarrying.
Include conclusions and actions taken or planned.
C.
Provide infornation on environmental inpact of blasting operations and any safeguards or alleviating actions taken or planned.
The information provided chould be in sufficient detail and supplemented by such cdditional data as night be available and deemed pertinent and necessary for full revicu and evaluation of the environmental impact.
Your reply should consist of three signed originals and 207 additional copics as a sequentially numbered supplccent to your Environmental Report.
The Final Environmental Statement for the Enrico Fermi Atomic Powcr Plant cannot be completed without these data. Please inform us when we night expect to receive the requested inforcation.
Sincerely, Reger S. Ecyd, Ascistant Director for Eoiling Water Reactors Division of Reactor Licensing I
cc: Arvin E. Upton, Esq.
DISTRIBUTION:
1 LcBocuf, Lamb, Leiby &
Docket File (Environ.) DNunn, DRL HacRae DR Reading File MKarman, OGC
,1821 Jefferson Place, N.W.
DRL Reading File GKnighton, REP Washington, D.C.
20036 DRL Branch File JCaplin, REP AEC PDR REP Files Local PDR PGustafson, ANL RClark, DRL WCRedman, Argonne NL SMiner, DRL JFelton, DR y
NMason, DRL Compliant. (2) /
HDenton, DRL FLogan, Dit CRESS #Q7nct>
,,, REP.
....Djh M/C#840758,759 T
.. =
. = -
g/.p-DMpTQ e
RS yd' JCa in:cis G,
...(
suneiac k 4/17/72 oarr >
7/.72.......
. 4/.../.2./.7.2_....4 /./[..../12...._4L J.k /12.....h/)2.72.........
rerun AEC lle lAevi 9 53) AEcM #340
- w g novea.ae.eerpano wnare=.s e..e m e.
__ _.. _