| 05000461/LER-1996-001, :on 960110,isolation of Mechanical Vacuum Pumps on Main Steam Line High Radiation Signal Occurred.Caused by Lack of Clarity of Meaning of Note in Table 3.3.2-1. Procedure Revised |
- on 960110,isolation of Mechanical Vacuum Pumps on Main Steam Line High Radiation Signal Occurred.Caused by Lack of Clarity of Meaning of Note in Table 3.3.2-1. Procedure Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-002, :on 960131,discovered HPCS Sys High Reactor Vessel Water Level seal-in & Ready to Reset Lamps.Caused by Spurious High Reactor Vessel Water Level Signal of Indeterminate origin.HPCS-1 Card Replaced |
- on 960131,discovered HPCS Sys High Reactor Vessel Water Level seal-in & Ready to Reset Lamps.Caused by Spurious High Reactor Vessel Water Level Signal of Indeterminate origin.HPCS-1 Card Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1996-003, :on 951118,failure of Procedure to Recognize MSL Radiation Monitor Detector Housing Tube as Secondary Cl Path Resulted in Operable Secondary Containment During Corrective Maint.Revised Procedure |
- on 951118,failure of Procedure to Recognize MSL Radiation Monitor Detector Housing Tube as Secondary Cl Path Resulted in Operable Secondary Containment During Corrective Maint.Revised Procedure
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-004, :on 960409,inadequate Job Preparation for Preventive Maint Task on Switchyard Breaker Caused MSIV Closure & Reactor Scram.Plant Procedures Revised |
- on 960409,inadequate Job Preparation for Preventive Maint Task on Switchyard Breaker Caused MSIV Closure & Reactor Scram.Plant Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(e)(2)(ii) |
| 05000461/LER-1996-005, :on 960411,failure to Follow Procedures During Completion of one-rod-out Interlock Test Results in Reactor Mode Switch Not Locked in Refuel During Control Rod Exercising as Required by TS |
- on 960411,failure to Follow Procedures During Completion of one-rod-out Interlock Test Results in Reactor Mode Switch Not Locked in Refuel During Control Rod Exercising as Required by TS
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-006, :on 960529,degraded Control Room HVAC Train Declared Inoperable.Caused by Personnel Error.Briefed Personnel Re Event & Developed Standing Order |
- on 960529,degraded Control Room HVAC Train Declared Inoperable.Caused by Personnel Error.Briefed Personnel Re Event & Developed Standing Order
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-007, :on 960529,discovered Inoperable Leak Detection Instruments.Caused by Personnel Error.Personnel Briefed Re Event & Labelled Both Reactor Water Cleanup Sys HX Rooms Ceiling Plugs |
- on 960529,discovered Inoperable Leak Detection Instruments.Caused by Personnel Error.Personnel Briefed Re Event & Labelled Both Reactor Water Cleanup Sys HX Rooms Ceiling Plugs
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-009, :on 960808,inadequate Procedure Leads to Failure to Properly Implement TS Surveillance.Caused Appears to Be Misinterpretation of Ts.Cps Procedure 9065.02 Performed at Frequency Required by TS |
- on 960808,inadequate Procedure Leads to Failure to Properly Implement TS Surveillance.Caused Appears to Be Misinterpretation of Ts.Cps Procedure 9065.02 Performed at Frequency Required by TS
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-010-01, Forwards LER 96-010-01, Plant Shutdown Due to Unidentified RCS Leakage from Degraded Reactor Recirculation Pump Seal Greater than TS Limit. Revised Rept Includes Cause of Event,Corrective Actions & Discussion of Similar Even | Forwards LER 96-010-01, Plant Shutdown Due to Unidentified RCS Leakage from Degraded Reactor Recirculation Pump Seal Greater than TS Limit. Revised Rept Includes Cause of Event,Corrective Actions & Discussion of Similar Events | |
| 05000461/LER-1996-011, :on 961002,EDG Surveillance Test Procedures Written to Satisfy TS (SR) 3.8.1.7, 3.8.1.12 & 3.8.1.19 Were Inadequate.Caused by Lack of Guidance in Surveillance Procedure.Procedures Revised |
- on 961002,EDG Surveillance Test Procedures Written to Satisfy TS (SR) 3.8.1.7, 3.8.1.12 & 3.8.1.19 Were Inadequate.Caused by Lack of Guidance in Surveillance Procedure.Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-012, :on 910316,failed to Demonstrate Operability of Offsite Power Sources within One Hr During Surveillance While Div 3 EDG Governor Speed Droop Control Set to 50% Due to Inadequate Procedures.Revised Procedures |
- on 910316,failed to Demonstrate Operability of Offsite Power Sources within One Hr During Surveillance While Div 3 EDG Governor Speed Droop Control Set to 50% Due to Inadequate Procedures.Revised Procedures
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-013-01, Forwards LER 96-013-01 Re Inadequate Actuator Design & Failure to Recognize Limitations of Resilient Seat Design Result in Local Leak Rate Test Feedwater Containment Isolation Valves | Forwards LER 96-013-01 Re Inadequate Actuator Design & Failure to Recognize Limitations of Resilient Seat Design Result in Local Leak Rate Test Feedwater Containment Isolation Valves | |
| 05000461/LER-1996-013, :on 961015,inadequate Actuator Design Occurred. Caused by Svc Conditions Experienced & Inherently Stringent Leakage Criteria.Procedure Revised |
- on 961015,inadequate Actuator Design Occurred. Caused by Svc Conditions Experienced & Inherently Stringent Leakage Criteria.Procedure Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000461/LER-1996-014-01, Forwards LER 96-014-01,containing Cause for Event & Corrective Actions to Prevent Recurrence Re Inadequately Tested Auxiliary Bldg Roof Plug.Commitments,Listed | Forwards LER 96-014-01,containing Cause for Event & Corrective Actions to Prevent Recurrence Re Inadequately Tested Auxiliary Bldg Roof Plug.Commitments,Listed | |
| 05000461/LER-1996-015-02, Forwards LER 96-015-02 Re Lack of Attention to Detail During Procedure Performance.Ler Has Been Revised to Remove Contributing Cause of Event & Corrective Action Associated W/Contributing Cause | Forwards LER 96-015-02 Re Lack of Attention to Detail During Procedure Performance.Ler Has Been Revised to Remove Contributing Cause of Event & Corrective Action Associated W/Contributing Cause | |
| 05000461/LER-1996-016-01, Forwards LER 96-016-01:re Residual Water Covering Portion of Disc/Seat Area During Testing Due to Design Not Allowing Complete Draining Results in Invalid Local Leak Rate Testing of Feedwater Containment Isolation | Forwards LER 96-016-01:re Residual Water Covering Portion of Disc/Seat Area During Testing Due to Design Not Allowing Complete Draining Results in Invalid Local Leak Rate Testing of Feedwater Containment Isolation | |
| 05000461/LER-1996-016, :on 950402,residual Water Observed Covering Portion of Disc/Seat Area.Caused by Plant Design Not Allowing Complete Draining of FW Lines.Drain Valves Installed on Bottom of Isvs & Rev of Test Procedures |
- on 950402,residual Water Observed Covering Portion of Disc/Seat Area.Caused by Plant Design Not Allowing Complete Draining of FW Lines.Drain Valves Installed on Bottom of Isvs & Rev of Test Procedures
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(c)(2)(v) |
| 05000461/LER-1996-017, :on 961102,div 3 DG Failed to Energize Emergency Bus within Required Time Limit.Caused by Personnel Misinterpretation of Setpoint Data.Added Note to Drawing to Clearly Show Setpoint |
- on 961102,div 3 DG Failed to Energize Emergency Bus within Required Time Limit.Caused by Personnel Misinterpretation of Setpoint Data.Added Note to Drawing to Clearly Show Setpoint
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-018, :on 961014,incorrect Torque Value for Control Rod Drive Hydraulic Control Units Was Specified by Supplier. Caused by Lack of Attention to Detail.All Hold Down Bolts on CRD HCUs Were Replaced |
- on 961014,incorrect Torque Value for Control Rod Drive Hydraulic Control Units Was Specified by Supplier. Caused by Lack of Attention to Detail.All Hold Down Bolts on CRD HCUs Were Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 21.21(b)(3) |
| 05000461/LER-1996-019, :on 961120,inadequate Surveillance Procedures Were Noted Due to Misinterpretation of TS Bases Results in Source Range Monitor Reactor Period Display Not Verified. Procedures CPS 9031.13 Will Be Revised |
- on 961120,inadequate Surveillance Procedures Were Noted Due to Misinterpretation of TS Bases Results in Source Range Monitor Reactor Period Display Not Verified. Procedures CPS 9031.13 Will Be Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1996-020, :on 961223,failure of CR Drive Hydraulic Control Unit Air Line Occurred Due to Overtightening Fitting During Maintenance to Correct Air Leak.Broken Air Line Was Replaced in Accordance with Mwr D61669 |
- on 961223,failure of CR Drive Hydraulic Control Unit Air Line Occurred Due to Overtightening Fitting During Maintenance to Correct Air Leak.Broken Air Line Was Replaced in Accordance with Mwr D61669
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |