ML20137J861

From kanterella
Jump to navigation Jump to search
Forwards LER 96-016-01:re Residual Water Covering Portion of Disc/Seat Area During Testing Due to Design Not Allowing Complete Draining Results in Invalid Local Leak Rate Testing of Feedwater Containment Isolation
Date released: 05/30/2020 Download: ML20137J861


:on 950402,residual Water Observed Covering Portion of Disc/Seat Area.Caused by Plant Design Not Allowing Complete Draining of FW Lines.Drain Valves Installed on Bottom of Isvs & Rev of Test Procedures
ML20137J885
Person / Time
Site: Clinton 
Issue date: 03/27/1997
From: Rohrscheib R
ILLINOIS POWER CO.
To:
References
Download: ML20137J885 (4)
Forwards LER 96-016-01:re Residual Water Covering Portion of Disc/Seat Area During Testing Due to Design Not Allowing Complete Draining Results in Invalid Local Leak Rate Testing of Feedwater Containment Isolation
ML20137J857
Person / Time
Site: Clinton 
Issue date: 03/27/1997
From: Connell W
ILLINOIS POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20137J857 (1)