. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

l C; o ' C y

I

(

l April 15,1969 Boyce H. Crier, Regional Director DOW CID:ICAL CGIPMPt, DOCKET No. 50-264 No prob 1 cms were noted during the inspection of the subject facility.

The radiation c;:posure experience for calendar year 196S was mini =al.

The licensec stated ho would inform us of any civil distrubance which could affect the reactor.

The fail safe design of the cafety circuit upon loss of electric po.icr was confirmed as satisfactory by tect.

i i

G. Flore111 Senior Reactor Inspector 8508200132 850725 PDR FOIA CONDIT85-483 PDR omc >

..C O.:.I.I I......

Tierelli/Jds.........

so. - c M

4-21,69

,j,

om>

a..

.. ~..

.. -...... -.....