Forwards Insp Repts 50-361/97-02 & 50-362/97-02 on 970112-0222 & Notice of Violation
ML20136G674
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 03/13/1997
From: Howell A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Ray H
SOUTHERN CALIFORNIA EDISON CO.
Shared Package
ML20136G677 List:
References
NUDOCS 9703180144
Download: ML20136G674 (5)


See also: IR 05000361/1997002

Text

{{#Wiki_filter:. g *"8G , UNITED STATES O - [ f'. NUCLEAR REGULATORY COMMISSION h REGloN IV ' e g. e 6 I' .f 611 RYAN PLAZA oRIVE, SUITE 400 k..../ AR LINGToN. TEXAS 760118064 MAR I 31997 Harold B. Ray, Executive Vice President Southern California Edison Co. San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, California 92674-0128 SUBJECT: NRC INSPECTION REPORT 50-361/97-02:50-362/97-02 AND NOTICE OF VIOLATION Dear Mr. Ray: An NRC inspection was conducted January 12 through February 22,1997, at your San Onofre Nuclear Generating Station, Units 2 and 3 reactor f acilities. The enclosed report presents the scope and results of that inspection. During the 6-week period covered by this inspection, your conduct of activities at the San Onofre f acilities was generally characterized by safety-conscious operation, sound engineering and maintenance practices, and careful radiological work controls. During this inspection period two violations were identified in the operations area, three situations involving f ailure to follow procedural or drawing requirements were identified regarding: (a) the order of valve manipulations while realigning shutdown cooling, resulting in the inadvertent transfer of about 1000 gallons of water from the refueling water storage tank to the reactor coolant system; and (b) maintaining reactor coolant system pressure within prescribed parameters. These violetions were the result of weaknesses in communication and operator attention to detail. In the engineering area, personnel conducting steam generator tube hydrostatic tests failed to maintain pressure for the length of time specified by procedure. These violations are cited in the enclosed Notice of Violation (Notice) and the circumstances surrounding the violations are described in detailin the enclosed report. Please note that you are required to respond to this letter and should follow the , instructions specified in the enclosed Notice when preparing your response. The NRC will /! use your response, in part, to determine whether further enforcement action is necessary l to ensure compliance with regulatory requirements. ' 1 p ,/,'I-- In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter, its enclosures, and your response will be placed in the NRC Public Document Room (PDR). >f To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be placed in the PDR without redaction. 9703180144 970313 OkEh,dgikggi / ggg]l g PDR .ADOCK 05000361 ' ,.. O PDR

i . . Southern California Edison Co. -2- Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely,

s Arth r T. HowellIll, Acting Director Division of Reactor Projects Docket Nos.: 50-361 50-362 License Nos. NPF-10 NPF-15 Enclosures: 1. Notice of Violation 2. NRC Inspection Report 50-361/97-02:50-362/97-02 cc w/ enclosures: Chairman, Board of Supervisors County of San Diego 1600 Pacific Highway, Room 335 San Diego, California 92101 Alan R. Watts, Esq. Woodruff, Spradlin & Smart 701 S. Parker St. Suite 7000 Orange, California 92868-4720 Sherwin Harris, Resource Project Manager Public Utilities Department City of Riverside 3900 Main Street Rive side, California 92522 R. W. Krieger, Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, California 92674-0128

. _ . _ _ _ _ . . _ _ - _ _ _ . .__ .. . _ . _ _ . - _ . . _ . _ _ _ _ _ . . _ _ _ _ _ . _ . _ _ _ . _ . _ _ . . i

. i ! Southern California Edison Co. 3- l 1 Dr. Harvey Collins, Chief

Division of Drinking Water and Environmental Management California Department of Health Services i >

P.O. Box 942732 Sacramento, California 94234-7320

Terry Winter, Manager

Power Operations San Diego Gas & Electric Company P.O. Box 1831

San Diego, California 92112 3- i Mr. Steve Hsu , Radiological Health Branch j- State Department of Health Services j P.O. Box 942732 i ' Sacramento, California 94234 i Mayor l City of San Clemente 100 Avenida Presidio San Clemente, California 92672 i Mr. Truman Burns \\Mr. Robert Kinosian California Public Utilities Commission i 505 Van Ness, Rm. 4102 San Francisco, California 94102 i

! 2 .i , , i i r T 4 - - - , . - ,

_ . _ . . Southern California Edison Co. -4- E-Mail report to D. Taylor (DRT) E-Mail report to T. Boyce (THB) E-Mail report to NRR Event Tracking System (IPAS) E-Mail report to Document Control Desk (DOCDESK) E-Mail report to R. Correia (RPC) bec to DCD (IE01)

/ bec distrib. by RIV: Regional Administrator Resident inspector DRP Director DRS-PSB i Branch Chief (DRP/F, WCFO) MIS System Senior Project inspector (DRP/F, WCFO) RIV File Branch Chief (DRP/TSS) M. Hammond (PAO, WCFO) WCFO File DOCUMENT NAME: R:\\ _S023/S0702RP.JAS To receive copy of document, indicate in box: "C" = Copy without enclosures "E" = Copy wth enclosures "N" = No copy RIV:RI:DRP/F l C:DRP/F l AD:@fy l l l JASloan * DFKirsch * ATHD%el[[ 03/ /97 03/ /97 03(y97V

  • previously concurred

OFFICIAL RECORD COPY

- . l Southern California Edison Co. -4- E-Mail report to D. Taylor (DRT) E-Mail report to T. Boyce (THB) E-Mail report to NRR Event Tracking System (IPAS) E-Mail report to Document Control Desk (DOCDESK) y E-Mail report to R. Correia (RPC) bec to DCD (IE01) I bec distrib by RIV: l ! Regional Administrator Resident inspector DBP Director DRS-PSB j Branch Chief (DRP/F, WCFO) MIS System Senior Project inspector (DRP/F, WCFO) RIV File l Branch Chief (DRP/TSS) M. Hammond (PAO, WCFO) WCFO File i i I I l I l 1 DOCUMENT NAME: R:\\ _S023/S0702RP.JAS To receive copy of document, indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy RIV:Rl:DRP/F l C:DRP/F AD:@ l l JASloan * DFKirsch * ATHU$el J 03/ /97 03/ /97 03(y97 I

  • previously concurred

OFFICIAL RECORD COPY i , ! ! ! _ _ _ _ ___________.___________.____ _____________.___ _ _ _______._______________.__.___________ ____ ___ _ _ ______.__________.___________ _ j }}