Revises 851015 Request for Extension Until Sixth Refueling Outage to Complete Reg Guide 1.97 & SPDS Commitments.Several Previously Identified Items May Be Accomplished During Fifth Refueling Outage.Status of Commitments Encl
ML20136G309
Person / Time
Site: North Anna Dominion icon.png
Issue date: 11/14/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Thompson H
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, RTR-REGGD-01.097, RTR-REGGD-1.097 85-683A, NUDOCS 8511220312
Download: ML20136G309 (5)


Text

m VINGINIA 11LECTHIC AND l'OWEH COMI%NY Ricnwonn,Vinauxur 2n261 W.L.StuwAur vara Psamineur Nuca. man OrsEATIONE November 14, 1985 Mr. Harold R. Denton, Director Serial No.

85-683A Office of Nuclear Reactor Regulation N0/DAS:vlh Attn:

Mr. H. L. Thompson, Jr., Director Docket No.

50-338 Division of Licensing License No. NPF-4 U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 EXTENSION REQUEST - REGULATORY GUIDE 1.97 AND SAFETY PARAMETER DISPLAY EYSTEM COMMITMENTS Your Confirmatory Order of June 14, 1984, specified a completion schedule for commitments of Supplement I to NUREG-0737 for North Anna Power Station (NAPS).

This Confirmatory Order contained a provision allowing the Director, Division of Licensing, to grant extensions of time for completing the identified items "for good cause shown". In our previous letter, Serial 85-683 dated October 15, 1985, we identified several items regarding Regulatory Guide 1.97 and the Safety Parameter Display System (SPDS) which we believed could not be completed prior to resuming power operation after the 5th refueling cycle for Unit I without impacting the outage duration.

This assessment was made based in large part on not having received the materials necessary to implement the required modifications as of thirty days prior to the beginning of the outage. As a result of our administrative controls, we requested a schedule extension until the end of the 6th refueling outage to complete those items (currently scheduled to occur from May 1,1987 to July 15, 1987). This represents an approximate sixteen months deferral in the completion schedule previously specified in the Confirmatory Order.

Material for most of these items has only recently been received onsite.

l In a " good faith" effort to complete these items, we have reassessed engineering and procurement status and now determine that several of the previously identified items may be accomplished during the 5th refueling outage for Unit 1.

This letter revises our previous request to delete those items we new consider achievable during the outage.

)

Oh ggg WAda' I i F

1-

}

f6'

.Vamornia ELECTRIC AND Powan CoweAny To Mr. liarold R. Denton Regulatory Guide 1.97 identifies the present status of the fourteen variables specified in our previous submittal.

It also adds one additional variable, neutron flux (Item B-1),

for which control room display instrumentation has not been delivered. We now expect to be in compliance with.27 (93%) of the overall 29 variable modifications following the Unit 1 outage, although the completion of 2 variable modifications is predicated on timely resolution of associated engineering open items or delivery of materials: as noted in the attachment. This represents an incremental improvement of approximately 31% over the 62% completion status identified in our previous submittal.

The two variable modifications identified as not achievable during this outage are due to lack of material delivery and quality assurance problems.

Safety Parameter Display System In our previous submittal, we indicated that approximately 83% of the 1055 data input connections to the SPDS computer would be installed by the end of the Unit i refueling outage.

Although the number of incomplete connections will be reduced by our " good faith" effort to complete the work on Reg. Guide 1.97 and SPDS, not all of the 1055 data input connections will be installed by the end of the outage. In addition, SPDS software verification and validation and operator training will not be completed during this outage.

i

D VamosurA Ex.ectarc 4xn Powna CoweAxv To Mr. Ilarold R. Denton We. believe that the above modifications to our previous submittal represent a " good faith" effort and a significant improvement in completion status. Should there be any change in the projected completion status identified in Attachment 1, we will notify you of such change. In summary, we request an extension until resuming power operation following the sixth refueling outage to complete the few remaining commitments for Reg. Guide 1.97 and SPDS for North Anna Unit 1.

If you have any questions on the above requests, please contact us.

Very truly yours, CA W. L. Stewart Attachment cc:

Dr. J. Nelson Grace Regional Administrator NRC Region II Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Mr. Edward J. Butcher, Acting Chief Operating Reactor Branch No. 3 Division of Licensing e

[ --

.r*

STATUS OF OUTSTANDING REG. GUIDE 1.97 COMMITMENTS COMPLETION VARIABLE TITLE VARIABLE #

THIS OUTAGE STATUS AS OF NOVEMBER 14, 1985 High Pressure A-8 Yes In process.

Safety Injection Flow Refueling Water A-10 Yes In process.

Storage Tank Level PORV Position A-11 Yes*

Materials from Technology for Indication Energy Corp. have not been delivered. Delivery onsite expected by November 19, 1985.

Pressurizer A-12 Yes In process.

. Liquid Temperature Neutron Flux B-1 No Installation complete except control room instrumentation.

Meters have not been delivered.

This item can be completed independent of the refueling outage. Upon delivery of the needed instrumentation, this item will be completed.

Containment B-12A N/A Requested reclassification to Sump Narrow Category 3 in letter dated May 10, Range Level 1985 (Serial 85-094). No addi-tional modifications presently planned.

Containment ~

B-12B No Replacement GEMS sensor cannot be Sump Wide purchased due to vendor QA problems.

Range Level Engineering evaluation currently in process to develop alternative solution. Alternative procurement necessary.

Containment B-14 Yes In process.

Isolation Valve Position J

... - (Cont'd)

COMPLETION VARIABLE TITLE VARIABLE #

THIS OUTAGE STATUS AS OF NOVEMBER 14, 1985 Boric Acid D-6 N/A Requested reclassification to Charging Flow Category 3 in letter dated May 10, 1985 (Serial 85-094). No additional modifications presently planned.

Main Steam D-19 Yes*

In process. Engineering is cur-Relief Valve rently being completed. Environ-Position mental qualification of fiber optic cable or hardware application with rerouting of seismic conduit needs to be resolved prior to performing modification.

Containment D-24 Yes In process.

Fan Heat Removal Volume Control D-29 Yes In process.

Tank Level Component D-30 Yes In process.

Cooling Water Temperature Component D-31 Yes In process.

Cooling Water Flow Gaseous E-9 Yes In process.

Waste Flow

  • Completion predicated on timely resolution of engineering open items and receipt of materials by specified delivery date.