ML20136F556

From kanterella
Jump to navigation Jump to search
Board Notification 85-077:discusses Staff Determination of Applicant Potential Matl False Statement of U-bolt Sample. Listed Memos Encl
Date released: 05/30/2020 Download: ML20136F556


Advises That IE Will Not Take Further Action Re Possible Matl False Statement Concerning U-bolt Supports,Pending NRC Review of Technical Issues.Licensee Performing Addl Evaluation Re Representativeness of U-bolt Support Sample
ML20137D123
Person / Time
Site: Comanche Peak 
Issue date: 04/04/1985
From: Vollmer R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: EISENHUT D G
Office of Nuclear Reactor Regulation
References
Download: ML20137D123 (1)
Assessment of Significance of Applicant U-Bolt Sample Discussed in Applicant Motion for Summary Disposition Re Cinched-Down U-Bolts.
ML20137C447
Person / Time
Site: Comanche Peak 
Issue date: 06/07/1985
From: Chen W
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To:
References
Download: ML20137C447 (9)
Forwards Wp Chen Review Re Significance of U-bolt Sample Discussed in Util Motion for Summary Disposition Re cinched-down U-bolts in Pipe Supports
ML20137C427
Person / Time
Site: Comanche Peak 
Issue date: 06/07/1985
From: Shao L
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To: NOONAN V S
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
References
Download: ML20137C427 (1)
Forwards LC Shao 850607 Memo Forwarding Technical Assessment of Significance of Util U-bolt Sample,Per Util Motion for Summary Disposition.Sample Reasonably Representative.Util Committed to 100% Insp of U-bolts
ML20137C403
Person / Time
Site: Comanche Peak 
Issue date: 06/28/1985
From: Noonan V
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To: TAYLOR J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
Download: ML20137C403 (1)
Responds to 841126 Request for Consideration of Whether Util Made Matl False Statement Warranting Enforcement Action Re U-bolt Supports.Ofc of Investigation Action & Views Required Re Util Deliberateness,Willfulness & Intent
ML20137C368
Person / Time
Site: Comanche Peak 
Issue date: 03/21/1985
From: Taylor J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: NOONAN V S
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
References
Download: ML20137C368 (1)
Board Notification 85-077:discusses Staff Determination of Applicant Potential Matl False Statement of U-bolt Sample. Listed Memos Encl
ML20137A035
Person / Time
Site: Comanche Peak 
Issue date: 08/20/1985
From: Noonan V
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To: ASSELSTINE, PALLADINO, ROBERTS
NRC COMMISSION (OCM)
References
TASK-AS, TASK-BN85-077, TASK-BN85-77
Download: ML20137A035 (2)
Suppls 850321 Response to 841126 Request for Determination Re Util Possible Matl False Statement to ASLB Concerning U-bolt Supports.Based on Listed Technical Considerations,No Matl False Statements Exist.No Enforcement Action Needed
ML20136G199
Person / Time
Site: Comanche Peak 
Issue date: 07/19/1985
From: Taylor J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: NOONAN V S
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
References
Download: ML20136G199 (1)
Discusses Alleged Significant Omission of Matl Info in Applicant Submission to Board & Parties Re Cinching Down of U-bolts.Omission May Constitute Matl False Statement Warranting Enforcement Action
ML20136F552
Person / Time
Site: Comanche Peak 
Issue date: 11/26/1984
From: Noonan V
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
To: DEYOUNG R C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
Download: ML20136F552 (2)