CPlea m in:rrt thic r~ port in th3 August 1985 r: port.

R: port Period August, 1985 UNIT SHUTDOWNS / REDUCTIONS BYRON No.

Date Type Hours Reason Method LER Number System Component Cause & Corrective Action to Prevent Recurrence 23) 8/1/85 S

14.5 B 2

Continued outage as a result of 100% Reactor Trip Startup Test from 7/27/85.

24) 8/1/85 F

21.2 A 1

Unit 1 equipment hatch failed it's surveillance; required to shutdown as per tech spec.

H*

3 I.M. removed wrong cable during surveillance on 25) 8/7/85 F

23.7 i

power range channels, which actuated the 2 out of 4 reactor trip logic.

H*

1 Inadequate N.D.E. records of safety injection 26) 8/29/85 F

51.8 2

valve weld, resulting in tech. spec. required shut.down.

CH :

Instrument Mechanic error.

1 CH : Tech. Spec. required shutdown 2

c cocce********

Byron 1 is continuing in its 100% Power Test Sequence.

0 Summary cos:cc*********

TYPE Reason Method

';vstem & Component F-Forced A-Equip Failure F-Admin 1-Manual Exhibit F & H S-Sch:d B-Maint or Test G-Oper Error 2-Manual Scram Iastructions for C-Refueling H-Other 3-Auto Scram Preparation of D-Regulatory Restriction 4-Continued Data Entry Sheet E-Operator Training 5-Reduced Load Licensee Event Report

& License Examination 9-Other (LER) File (NUREG-0161) 8511200313 851109 PDR ADOCK 05000454 (0625M)