UNITED STATES g
8 NUCLEAR REGULATORY COMMISSION 0
WASH 6NGTON, D. C. 20056
- .e*
DUKE POWER COMPANY D0CKET NO. 50-369 McGUIRE NUCLEAR STATION, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 48 License No. NPF-9 1.
The Nuclear Regulatory Comission (the Comission or the NRC) has found that:
o A.
The application for amendment to the McGuire Nuclear Station, Unit 1 (the facility) Facility Operating License No. NPF-9 filed by the Duke Power Company (the Itcensee) dated December 10, 1984, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I;
B.
The facility will operate in conformity with the application as amended, the provisions of the Act, and the regulations of the Commission; C.
There is reasonable assurance: (1) that the-activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations set forth in 10 CFR Chapter I; D.-
The issuance of this amendment will not be inimical to the comon defense and security or the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been 1
satisfied.
i 2.
Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-9 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through
?
Amendment No. 48, are hereby incorporated into this license. The 8511200187 851112 i
PDR ADOCM 05000369
(
P PDR l
l l
2-licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION 1 Elinor G. Adensam, Chief v
Licensing Branch No. 4 Division of Licensing
Attachment:
Technical Specification Changes Date of Issuance: November 12, 1985
UNITED STATES 8
NUCLEAR REGULATORY COMMISSION o
h WASHINGTON, D. C. 20666 DUKE POWER COMPANY DOCKET NO. 50-370 McGUIRE NUCLEAR STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 29 License No. NPF-17 1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment to the McGuire Nuclear Station, Unit 2 (the facility) Facility Operating License No. NPF-17 filed by the Duke Power Company (the licensee) dated December 10, 1984, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I;
B.
The facility will operate in conformity with the application, as amended, the provisions of the Act, and the regulations of the Comission; C.
There is reasonable assurance: (i)thattheactivitiesauthorizedby this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations set forth in 10 CFR Chapter I; D.
The issuance of this license amendment will not be inimical to the comon defense and security or to the health and safety of the public; E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachments to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-17 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 29, are hereby incorporated into this license.
L_
' The Itcensee shall operate-the facility in accordance with the Tech-nical Specification: and the Environmental Protection Plan.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION 1 Elinor G. Adensam, Chief Licensing Branch No. 4 Division of Licensing
Attachment:
Technical Specification Changes Date of Issuance: November 12,1985 I
?
l
ATTACHMENT TO LICENSE AMENDMENT NO. 48 FACILITY OPERATING LICENSE NO. NPF-9
' DOCKET NO. 50-369 AND TO LICENSE AMENDMENT NO. 29 FACILITY OPERATING LICENSE NO. NPF-17 DOCKET NO. 50-370 L
Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised page is identified by Amendment number and contains a vertical line indicating the area of change. The corresponding over-leaf page is also provided to maintain document completeness.
Amended Overleaf M
Page 6-2 6-1 L
t
'l i
_, - -, -, _ _., - - +,. _ _... -,. _,.
.__..w__.-
y__.._,r_,
~ - -.. --,
6.0 ADMINISTRATIVE CONTROLS k
6.1 RESPONSIBILITY 6.1.1 The Station Manager shall be responsible for overall unit operation and shall delegate in writing the succession to this responsibility during his absence.
6.1.2 The Shift Supervisor (or during his absence from tne. control room, a designated individual) shall be responsible for the control room command function. A management directive to this effect, signed by the Manager of
. Nuclear Production shall be reissued to all station personnel on an annual basis.
6.2 ORGANIZATION OFFSITE 6.2.1 The offsite organization for unit management and technical support shall be as shown in Figure 6.2-1.
UNIT STAFF
,6.2.2 The unit organization shall be'as shown in Figure 6.2-2 and:
a.
Each on-duty shift shall be composed of at least the minimum shift
[
crew composition shown in Table 6.2-1; b.
At least one licensed Operator for each unit shall be in the control room when fuel is in either reactor.
In addition, while either unit is in MODE 1, 2, 3, or 4, at least one licensed Senior Operator shall be in the control room; A Health Physics Technician # shall be on site when fuel is in either c.
reactor; d.
All CORE ALTERATIONS shall be observed and directly supervised by either a licensed Senior Operator o-licensed Senior Operator Limited to Fuel Handling who has nc..cher concurrent responsibil-ities during this operation; A site Fire Brigade gf at least five members shall be maintained e.
onsite at all times.
The Fire Brigade shall not include three members of the minimum shift crew necessary for safe shutdown of the unit and any personnel required for other essential functions during a fire emergency; and
- The Health Physics Technician and Fire Brigade composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence, provided immediate action is taken to fill the required positions.
McGUIRE - UNITS 1 and 2 6-1
ADMINISTRATIVE CONTROLS f.
Administrative procedures shall be developed and implemented to limit the working hours of unit staff who perform safety-related functions; e.g.,
licensed Senior Operators, licensed Operators, health physicists, auxiliary operators, and key maintenance personnel.
Adequate shift coverage shall be maintained without routine heavy use of overtime. The objective shall be to have operating personnel work a normal 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> day with alternating 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and 36 hour4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> work l
week while the unit is operating. However, in the event that unfore-seen problems require substantial amounts of overtime to be used, or during extended periods of shutdown for refueling, major maintenance or major plant modifications, on a temporary basis, the following guidelines shall be followed:
1)
An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight, excluding shift turnover time; 2)
An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in any 24-hour period, nor more than 28 hours3.240741e-4 days <br />0.00778 hours <br />4.62963e-5 weeks <br />1.0654e-5 months <br /> in any 48-hour period, nor more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any 7-day l
period, all excluding shift turnover time; 3)
A break of at least 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> should be allowed between work periods, including shift turnover time; and 4)
Except during extended shutdown periods, the use of overtime should be considered on an individual basis and not for the entire staff on a shift.
Any deviation from the above guidelines shall be authorized by the Station Manager or his deputy, or higher levels of management, in accordance with established procedures and with documentation of the basis for granting the deviation. Controls shall be included in the procedures such that individual overtime snall be reviewed monthly by the Station Manager or his designee to assure that excessive hours have not been assigned. Routine deviation from the above guidelines is not authorized.