Table 2.1-1 MILLSTONE NUCLEAR POWER STATION - UNIT No.

1 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASFC 1984 r

QUARTER'.Y Est. Total i

Units TOM Error, 5 JAN.

FEB.

MARCH i

. Fission and Activation Products Totsi released (not in-Ci

+01 bdingH-3, Gases, Alpha) 7.25 E-03 1.64 E-03 8.36 E-03 1.73 E-02

. Average diluted con-aci/n1 ntration during period

  • 1.91 E-09 4.44 E-10 1.60 E-09 1.36 E-09

-Forcent of applicatie g

0.010

..it **

  • Based on limit of 1.5 mrem whole body dose per quarter - E.T.S. 2.4.1.2.D

~

5. Tritium

. Totc1 Released C1 2.49 E-01 6.28 E-03 5.14 E-01 7.69 E-01

. Averace diluted con-41/=1 cntratien during period

  • 6.55 E-08 1.70 E-09 9.85 E-08 6.06 E-08 g

C. Disco 1ved and Entrained Gases 1.50E+01

1. Total Released C1 1.13 E-02 3.63 E-06 1.96 E-05 1.13 E-02
2. Average diluted con-uCi/n1 centration during period
  • 2.97 E-09 9.84 E-13 3.75 E-12 8.90 E-12 8509250154 850912" DR ADOCK 05000 5

g D. Gross Alpha Radioactivity p

1. 50E+ 01
1. Total Released Ci

~~~-~~~

2 1.70 E-05

  • 6.36 E-06 kl.77 E-05

^ During periods of actual release.

E.

Volu:.c of waste re-1.00E+01 11 c7~,.

2th.ted(Prior to dilution) 2.83 E+05 1.59 E+05 2.08 E+05 6.50 E+05 i

I I

F. Volu c of dilution 1.00E+01 li ers j

n'.cr ured during period 1.49 E+11 1.59 E+11 1.69 E+11 4.77 E+11

7

.rg-Table 2.1-1 Continued

."q-I

~5i MILLSTONE NUCLEAR POWER STATION - UNIT No.

EFFLUENT AND WASTE DISPOSAL REPORT wEE LIQUID EFFLUENTS - SUhMATION OF ALL RELEASES

. $_f.-

year _1984 --

QUARTERLY Est. Total Units TOT E

. Error, %

6.
  • APRIL MAY JUNE n

3 A, Fission and Activation Products 1.50E+01

},_ Total released (not in-C1 1.95E-03 2.34E-03 1.17E-02 1.60E-02 cluding H-3, Gases, Alpha)

2. Average diluted con-

,ggj,y

. centration during period

  • 1.15E-09 1.81E-08 1.04E-08 5.41E-09
3. Percent of applicable g

limit **

n Based on limit of 1.5 mrem whole body dose per quarter E.T.S. 2.4.1.2.D a

B. Tritium 1.50E+01

1. Total Released Ci 5.20E-01 4.88E-01 4.55E+00 5 56E40
2. Average diluted con-21/d centration during period
  • 3.06E-07 3.78E-06 4.03E-06 1.88E-06 _,

C. Dissolved and Entrained Gases 1.50E+01

1. Total Released Ci 1.78E-04 1.84E-04 6.18E-06
2. Average diluted con-

""1/m1 1.58E-10 6.22E-11 _

centration during period

  • 3.64E-12 D. Gross Alpha Radioactivity 1.50E+01
1. Total Released Ci 6-9. 60E-06 dE 2.50E-05 6 6.48E-05 During periods of actual release.

1.00E+01 i

E.

Volume of waste re-leksed(Prior to dilution) 1.60E+05 5.00E+05 2.16E+06 2.82E+06 li ers 1.00E+01 F. Volume of dilution li ers rater used during period 1.26 E+11 9.91 g+1n 1.41 E+11 3.29 E+11

l TABLE 2.1-1 MIILSTONE NUCLEAR POWER STATION - UNIT No.

1 EFFIRENT AND WASTE DTS*0SA1 REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES Year 1984 Units QUARTERLY Est. Total JULY AUGUST' SEPTEMBER TOTALS Error, 5 l}

A. Fissien and Activation Products

1. Total released (not in-Ci 1.50E+01 cluding H-3, Gases, Alpha) 9.97E-04 7.24E-04 1.05E-03 2.78E-03
2. Average diluted con-
  • I cf.ntration during period
  • 1.69E-10 3.66E-10 4.63E-10 2.73E-10
3. Percent of applicable g

lirit **

2.07E-037.

l 4

B. Tritiu

1. Totel Released 1.50E+01 C1 5.38E-01 4.83E-01 4.25E-02 1.06E+00 l
2. Average diluted con-
  1. CII*1 centration during period
  • l 9.12E-08 2.44E-07 1.87E-08 1.04E-07 i

C. Dissolved and Entrained Oeses i

i

1. Total Released 1.50E+01 C1

~

~~~~~~

e osr-01 1.73E-03 6.68E-03

2. Average diluted con-uCi/el centration during period *

~~~~~~

8.39E-10 8.74E-10 6.55E-10 D. Gross Alpha Radioactivity

1. Total Released Ci 3.45E-05 62.32E-05 f6.36E-06
  • During periods of actual release.

F.. Volume of waste re-1,003401

} cased (Prior to dilution) 6.90E+05 3.86E+05 1.06E+05 1.18E+06 F. Volu:ne of dilution 1 ters nier used during period 1.70 E+11 1.67 E+11 1.65 E+11 5.02 E+11

l 4

TABLE 2.1-1 MILLSTONE NUCLEAR POWER STATION - UNIT No.

1 EFF111ENT AND IIASTE DISPOSAL REPORT LIQUID EFFLUENTS - SUWATION OF ALL RELEASIS YGar 84 QUARTER'.Y Es'.. Total Units OCT.

NOV.

DEC.

TOTALS Error, 5 A. Fission and Activation Products

1. Total released (not in-Ci 5.BBE-04 1.06E-04 1.05E-03 1.74E-03 1.50E+01 cludirg H-3, Gases, Alpha) aci/mi 1.78E-10 3.34E-11 2.35E-10 l'.60E n a on p r od *-
3. Percent of applienble g

1.33E-03%

limit **

B. Tritin:o

1. Total Released 1.50E+01 C1 1.67E-01 4.23E-01 5.95E-01 1.19E+00
2. Averace diluted con-201/n1 5.05E-08 1.33E-07 1.33E-07 1.09E-07 centration during period
  • C. Disco 1ved and Entrained Gases 1.50E+01
1. Total Released Ci 1.86E-04 1.65E-04 8.40E-04 1.19E-03
2. Average diluted con-uci/n1 5.62E-11 5.21E-11 1.88E-10 1.09E-10 centration during period
  • D. Gross Alpha Radioactivity
1. Total Released Ci dbl.'14E-05
f!:1.17E-05 62.11E-05 1.50E+01
  • During periods of actual release.

1.00D 01 literc 2.28E+05 1.95E+05 3.84E+05 8.07E+05 ase or to d u on)

F. Volu c of di3ution 1 ers ester uced during perjod 1.69 E+11 1.60 Ef-11 1.71 E+11 5.00 E+11 S

-,, - -