Amends Coc GDP-2 to Allow Vent Path from Compression Loop to Cascade to Be Open in Standby Operational Mode for X-326 ERP,X-333 Law & X-330 Tails Withdrawal Stations
ML20135C315
Person / Time
Site: Portsmouth Gaseous Diffusion Plant
Issue date: 02/04/1997
From: Paperiello C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: John Miller
UNITED STATES ENRICHMENT CORP. (USEC)
Shared Package
ML20135C316 List:
References
TAC-L32006, NUDOCS 9703030485
Download: ML20135C315 (3)


Text

- , - - - - .- -

February 4, 1997 Mr. James H. Miller Vice President, Production U. S. Enrichment Corporation 2 Democracy Center i

6903 Rockledge Drive a Bethesda, MD 20817

SUBJECT:

CERTIFICATE AMENDMENT REQUEST - PORTSMOUTH GASEOUS DIFFUSION PLANT WITHDRAWAL STATIONS STANDBY OPERATIONAL MODE (TAC NO. L32006)

Dear Mr. Miller:

In accordance with your application dated November 8,1996 and supplements dated December 13,1996, and January 16,1997, and pursuant to Part 76 to Title 10 of the Code of Federal Regulations, Certificate of Compliance GDP-2 is hereby amended to allow the vent path from the compression loop to the cascade to be open in the Standby Operational Mode for X-326 ERP, X-333 LAW, and X-330 Tails Withdrawal Stations.

2 Accordingly, Condition 9 has been revised to include the dates of November 8,1996, and January 16,1997.

To be more consistent, we have changed the wording in Condition 2 from Revision Number to Amendment Number.

All other conditions of this certificate shall remain the same.

Enclosed are copies of the revised Certificate of Compliance and the Compliance Evaluation Report.

Sincerely, ORIGNIAL SIGNED BY Carl J. PaperiellO Carl J. Paperiello, Director 9703030485 970204 Office of Nuclear Material Safety I

PDR ADOCK 07007002 C PDR , and Safeguards I

Docket 70-7002 ed en 0 hk I

Enclosures:

As stated (2) 1 1

cc: Mr. Randall DeVault, DOE ,

I Mr. Dale Allen, PORTS s DfSTRIBUTION: (Controf No. 030S)

Docket 70-7002 NRC File Center PUBLIC f

KO'Brien. Rlli NMSS Dir. Off r#

CCox, Riti NMSS r# FCSSr# WSchwink, FCOB TWoonk SPB SPBr# OGC GSheer, Rlli G:WENTLTR2.YHF criPROOrtD/Ft9nUAAY 4,1997 *See Promus Cornmece OFC SPB' SPB' SPB' SPB' FCSS' NN}

NAME YFaraz:ij DHoadley DMartin RPierson ETenEyck C riello DATE 1/30/97 1/30/97 1/30/97 1/31/97 2/4/97 l 3 I [/97 C = C 3VER E = COVER & ENCLOSURE N = ido COPY FFICIAL REC R C PY 030094

Mr. James H. Miller Vice President, Production U. S. Enrichment Corporation 2 Democracy Center 6903 Rockledge Drive Bethesda, MD 20817

SUBJECT:

CERTIFICATE AMENDMENT REQUEST - PORTSMOUT)VGASEOUS DIFFUSION PLANT WITHDRAWAL STATIONS STANDBY OPERATIONAL MODE (TAC NO.

L32006)

Dear Mr. Miller:

In accordance with your application dated Nov ber 8,1996 and supplements dated December 13,1996, and January 16,199 , /and pursuant to Part 76 to Title 10'of the Code of Federal Regulations, Certificat f Compliance GDP-2 is hereby amended to allow the vent path from the compression op to the cascade to be open in the Standby Operational Mode for X-326 ERP -333 LAW, and X-330 Tails Withdrawal Stations.

Accordingly, Condition 9 ha een revised to include the dates of November 8,1996, and January 16,1997.

To be more consist t, we have changed the wording in Condition 2 from Revision Number to Ame ment Number.

All other c ditions of this certificate shall remain the same.

Encl ed are copies of the revised Certificate of Compliance and the Compliance E uation Report.

Sincerely, Carl J. Paperiello, Director Office of Nuclear Material Safety and Safeguards Docket 70-7002 Certificate GDP-2 Amendment 01

Enclosures:

1. Certificate of Compliance GDP.2
2. Compliance Evaluation Report cc: Mr. Randall DeVault, DOE Mr. Dale Allen, PORTS DISTRIBUTION: (Control No. 040S)

Docket '.0-7002 NRC File Center PUBLIC KO'Brien, Rill MMessier, LFDCB 1 CCox, Rill NMSS r/f FCSS r/f WSchwink, FCOB TWeenk, SPB l

MHorn, SPB SPB r/f OGC GSheer, Rill G:WENTLTR2.YHF OFC JPB SP,8 . SfB SP,8 FCSk NMSS NAME hbl"" d e[ * 'DW@ R [or ETen yck CPaperiello DATE / /97 / /97 / /97 / /97 p./V/97 / /97 l C = C ]VER E = COVER & ENGLOSuRE N = HO COPY  !

OFFICIAL RECORD COPY l l

1 .

Mr. James H. Miller Vice President, Production i U. S. Enrichment Corporation 2 Democracy Center 6903 Rockledga Drive BethesdN MD 20817 f

/

SUBJECT:

CERTIFICATE AMENDMENT REQUEST - PORTSMOUJH GASEOUS DIFFUSION PLANT WITHDRAWAL STATIONS STANDBY OPERATIONAL MODE (TAC NO.

L32006)

Dear Mr. Miller:

In accordance with your application dated ember 8,1996 and supplements dated

) ' December 13,1996, and January 16,1 7, and pursuant to Part 76 to Title 10 of the l

Code of Federal Regulations, Certifi e of Compliance GDP-2 is hereby amended to allow the vent path from the compress' n loop to the cascade to be open in the Standby Operational Mode for X-326 Ed, X-333 LAW, and X-330 Tails Withdrawal Stations.

Accordingly, Condition 9 s been revised to include the dates of November 8,1996, and January 16,1997.

To be more consistent, we have changed the wording in Condition 2 from Revision '

Number to Ameffdment Number.

All other nditions of this certificate shall remain the same.

Enc sed are copies of the revised Certificate of Compliance and the Compliance aluation Report. i I

Sincerely, Carl J. Paperiello, Director Office of Nuclear Material Safety and Safeguards Docket 70-7002 Certificate GDP-2 Amendment 01

Enclosures:

1. Certificate of Compliance GDP-2
2. Compliance Evaluation Report cc: Mr. Randall DeVault, DOE Mr. Dale Allen, PORTS DISTRIBUTION: (Control No. 030SI Docket 70-7002 NRC File Center PUBLIC KO'Brien, Rill PMDA CCox, Rill NMSS r/f FCSS r/f WSchwink FCOB TWecnk, SPB SPB r/f OGC GShear, Rill G:WENTLTR2.YHF OFC SPB 6 Sh h ,SPB. SPB g NAME YFark: hbbadley htin Rhon DATE 1 /f4197 I M97 2

/ /(/97 I b; /b7 / /97 / /97 C = G JVER 5 = COVER E ENGL0sURE N = I40 COPY OFFICIAL RECORD COPY I