ML20134P542

From kanterella
Jump to navigation Jump to search
Effluent & Waste Disposal,Semiannual Rept,Jan-June 1985
ML20134P542
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 06/30/1985
From: Graesser K
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
0569R, 569R, NUDOCS 8509060357
Download: ML20134P542 (39)


Text

e Commonwe:lth Edison Zion G:.nar:: ting St; tion 3

101 Shiloh Blvd.

Zion, Illinois 60099 Telephore 312/746-2084 August 13, 1985 tRIC111LFyff r g ;,'-~I e3; l__

Mr. James G.

Keppler

-C

_1 Regional Administrator i_

4PT [ f. [1.

Directorate of Inspection and Enforcement

~-

Region III

_{ _

[&p Y; v H,f-7 U.S.

Nuclear Regulatory Commission cz 700 Roosevelt Road yf Glen Ellyn, Illinois 60137

Subject:

Zion Nuclear Power Station Operating Report, NRC Dockets 50-295 and 50-304

Dear Mr. Keppler:

Enclosed is the radioactive effluent report for January through June, 1985 for Zion Nuclear Power Station.

One copy of this report is provided for your use and 39 copies are being submitted directly to Mr. D.

Eisenhut, Deputy Director of the Office of Nuclear Reactor Regulation.

Sincerely yo rs,

/

K.

L.

Graesser Station Manager Sion Station KLG/BT/gn Enclosure r

r g62

'lt 8509060357 850630 AUG 3 01985 PDR ADOCK 05000295 R

PDR

e ZION STATION sv EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES A. Gaseous Effluents Released - Summary Sheet First Units January February March Quarter 1.

' Gross Radioactivity Releases

{

~

i a.

Total Release Ci 3.8 E+2 1.0 E+3 5.5 E+1 1.4 E+3 i

I b.

Max. Release Rate 2 pCi/sec 1.7 E+3 8.7 E+3 6.2 E+2 8.7 E+3 i

t

{

c.

% of Quarterly Limit 5.0 E-1 1.3 EO 7.3 E-2 1.9 EO (9600 pCi/sec) i l

2.

Iodine Releases a.

Total 1-131 Ci 6.1 E-4 4.0 E-4 1.9 E-4 1.2 E-3

[

i b.

% of I-131 Limit 2 i

j 3.

Particulate Releases a.

Gross Radioactivity C1 2.0 E-3 9.7 E-4 1.8 E-4 3.2 E-3 f

j j

b.

Gross Alpha Radioactivity Ci 8.7 L-6 6.9 E-4 4.9 E-5 7.5 E-4 l

c.

% of Particulate with y

l Half Lives > 8 Days 2 i

i 4.

Sum of I-131 & Particulate With Half Lives Greater Than 8 Days j

j a.

Sum of above C1 2.5 E-3 5.2 E-4 3.7 E-4 3.4 E-3 b.

% of Limit (2 pC1/sec) 4.7 E-2 1.1 E-2 6.9 E-3 6.5 E-2 c.

% of Quarterly Limit j

2.0 E-1 4.1 E-2 2.9 E-2 2.7 E-1 (0.16 pC1/sec)-

l 5.

Tritium Releases i

a.

Total Release Ci 1.1 EO 6.9 EO 3.0 E0 1.1 E+1 j

i l

1- - Gross Gaseous Radioactivity Maximum Release Rate - 60,000 pCi/sec l

l 2-Iodine & Particulate Limits are expressed as total limit -

l See Item A4 above.

<LLD - No detectable activity above background i

f TbN 0569R 2

////

L -

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPDRT 1985 GASE0US EFFLUENTS - ELEVATED RELEASE A. Gaseous Effluents Released - Isotopes fsotopes Units January February March Qua t r 1.

Gross Radioactivity Releases AR-41 Ci 7.8 [-3 2.2 E-1 2.5 E-3 2.3 E-1 Kr-85

<LLD 4.0 E-1 1.4 E0 1.8 EO Kr-85M

<LLD

<LLD

<LLD

<LLD Kr-87 Ci

<LLD 4.2 E-3

<LLD 4.2 E-3 Kr-88 3.2 E-1 6.1 E-3 4.4 E-2 3.7 E-1 Xe-131 Ci

<LLD

<LLD

<LLD

<LLD Xe-131M 3.4 E-1 2.7 E0 2.4 E-1 3.3 EO Xe-1331 3.2 E+2 1.0 E+3 5.1 E+1 1.4 E+3 Xe-133M 9.0 E-1 1.7 E-1 1.8 E-2 1.1 EO Xe-1351 Ci 6.0 E+1 8.2 E0 2.0 EO 7.0 E+1 Xe-135M

<LLD

<LLD

<LLD

<LLD Xe-138

<tLD

<LLD

<LLD

<lLD Ci Ci

<LLD - No detectable activity above background 1 - Includes R14 data 0569R 3

(

j

~_

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASECUS EFFLUENTS - ELEVATED RELEASE

a. Gaseous Effluents Released - Isotopes (continued)

Isoopej Units January February March Ou r

2.

Iodine Releases Ma-74 Ci 6.7 E-7 6.2 E-7

<LLO 1.3 E-6 Mn-54

<LLD

<LLO 1.1 E-5 1.1 E-5__

Co-58 Ci 1.5 E-8 1.4 E-6 4.2 E-7 1.8 E-6 Co-60 1.0 E-6 1.9 E-6 1.7 E-4 1.7 E-4 Ci Br-82 3.1 E-6 8.6 E-7 1.0 E-6 5.0 E-6 Rb-88

<llD

<LLD

<LLO

<LLO Ci I-131 Ci 6.1 E-4 4.0 E-4 1.9 E-4 1.2 E-3 1-132 1.5 E-5 9.4 E-5

<LLD 1.1 E-4 I-133 1.6 E-4 1.8 E-5 1.9 E-5 2.0 E-4 I-134 1.4 E-6

<LLO

<LLO 1.4 E-6 Cs-134 3.5 E-6 3.9 E-7 1.5 E-7 4.0 E-6 I-135 Ci 1.1 E-4 2.0 E-7

<LLO 1.1 E-4 Cs-136 7.3 E-8

<LLD

<LLD 7.3 E-8 Cs-137 2.2 E-6 1.0 E-6 1.5 E-9 3.2 E-6 Cs-138 3.5 E-6 4.6 E-6

<LLD 8.1 E-6

<LLD - No detectable activity above background 0569R 4

L

ZION STATION EFFLllENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASE0US EFFLUENTS - ELEVATED RELEASE B. Gaseous Effluents Released - Isotopes (continued)

Isotopes Units

.lanuary February March 0

r 3.

Particulate Releases

__Na-24 Ci 8.7 E-6 1.8 E-6 1.5 E-7 1.1 E-5 Mn-54

<LLD

<LLD

<LLD

<LLD Mn-56 1.8 E-7

<LLD

<LLD 1.8 E-7 Co-58 Ci 3.1 E-8 1.1 E-7 2.4 E-7 3.8 E-8 Co-60 1.4 E-6 1.7 E-7 5.9 E-7 2.2 E-6 Ci Br-82 9.1 E-8

<LLD

<LLD 9.1 E-8 Rb-88 Ci 1.8 E-3 7.0 E-5 1.8 E-4 2.1 E-3 Sr-891 Sr-901 Sr-91 C1 1.2 E-7

<LLD

<LLD 1.2 E-7 Sr-92

<LLD

<LLD

<LLD

<LLD Nb-95

<LLD

<LLD

<LLD

<LLD Ci Mo-99 3.3 E-7

<LLD

<lLD 3.3 E-7 i

Tc-99M 8.5 E-7

< LLD

<LLD 8.5 E-7

<LLD - No detectable activity above background 1 - Waiting for analysis results - Data will be presented in an errata to the Semi-Annual Report 0559R-5 L

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEOUS EFFLUENTS - ELEVATED RELEASE B. Gaseous Effluents Released - Isotopes (continued) fsotopes Units January February March 0

r 3.

Particulate Releases (continued)

Ru-103 C1

<LLD

<LLD

<LLD

<lLD Aq-11 DM

<LLD

<LLD 7.1 E-9 7.1 E-9 Sb-122 Ci

<LLD 4.9 E-7

< LLD 4.9 E-7 I-1 31 1.7 E-5 1.5 E-6 3.8 E-8 1.9 E-5 I-132 1.1 E-5

<LLD

<LLD 1.1 E-5 Te-132 1.3 E-7

<LLD

<LLD 1.3 E-7 I-133 Ci 2.0 E-5

<LLD 2.7 E-7 2.0 E-5 Cs-134 2.6 E-5 2.6 E-5 7.2 E-8 5.2 E-5 I-135 1.9 E-5

<LLD

<LLD' 1.9 E-5 l

Cs-136 Ci l

1.5 E-6

<LLD

<LLD 1.5 E-6 Cs-137 2.8 E-5 2.6 E-5 6.5 E-7 5.5 E-5 Cs-138 4.3 E-5

<LLD 7.0 E-7 4.4 E-5 Ba-13i

<LLD

<LLD

<LLD

<LLD Ba-140 Ci 2.4 E-7

<lLD

<LLD 2.4 E-7 La-140 5.9 E-8

<tLD

<LLD 5.9 E-8 W-187 Ci 2.8 E-8

<LLD

<LLD 2.8 E 8 __

Bi-214

<LLD

<LLD

<llD

<LLD Pb-214

<Lt D

<LLD

<LLD

<LLD 1

<tLD - No detectable activity _above background 0569R 6

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES A. Gaseous Effluents Released - Summary Sheet Second i

Units April May June Quarter 1.

Gross Radioactivity Releases a.

Total Release Ci 5.7 E+1 1.2 E+2 9.0 E+2 1.1 E+3 l

l b.

Max. Release Rate 2 pC1/sec 3.3 E+2 5.0 E+2 1.0 E+3 1.0 E+3 c.

% of Quarterly Limit 7.6 E-2 1.6 E-1 1.2 E0 1.4 E0 (9600 pCi/sec) 2.

Iodine Releases a.

Total I-131 Ci 2.8 E-5 7.1 E-6 1.8 E-5 5.3 E-5 b.

% of I-131 Limit 2 3.

Particulate Releases a.

Gross Radioactivity C1 3.2 E-4 5.1 E-4 7.6 E-3 8.4 E-3 b.

Grass Alpha Radioactivity C1 1.9 E-4 2.4 E-4 1.5 E-4 5.8 E-4 c.

% of Particulate with g

Half Lives > 8 Days 2 4.

Sum of I-131 & Particulate With Half Lives Greater Than 8 Days a.

Sum of above Ci 8.6 E-5 1.7 E-4 7.4 E-3 7.7 E-3 b.

% of Limit (2 pCi/sec) 1.7 E-3 3.2 E-3 1.4 E-1 1.4 E-1 c.

% of Quarterly Limit 6.9 E-3 1.4 E-2 5.9 E-1 6.2 E-1 (0.16 pCi/sec) 5.

Tritium Releases a.

Total Release C1 6.7 E-1 3.2 E-1 4.2 E-1 1.4 EO 1-Gross Gaseous Radioactivity Maximum Release Rate - 60,000 pCi/sec 2-Iodine & Particulate Limits are expreesi4 Sa total limit -

See Item A4 above.

<LLD - No detectable activity above background 0569R' 7

L

r q

ZION STATION EFFLUENT AND WASTE DISPOSAL SEM1 ANNUAL REPORT 1985 GASEOUS EFFLUENTS - ELEVATED RELEASE B.

Gaseous Effluents Released - Isotopes Isotopes Sec nd Units April May June Released Quarter 1.

Gross Radioactivity Releases Ar-41 Ci

<LLD 8.3 E-1 3.2 E-1 1.2 EO Kr-85 4.7 E0 1.6 E-4

<LLD 4.7 EO Kr-85M

<LLD

<LI D 9.7 E-3 9.7 E-3 Kr-87 Ci 5.5 E-1 1.3 E-1 2.8 E-2 7.1 E-1 Kr-88 1.7 E0

<LLD 7.1 E-0 8.8 EO Xe-127

<LLD 6.0 E-8

<LLD 6.0 E-8 Xe-131 Ci

<LLD

<LLD

<LLD

<LLD Xe-131M 8.4 E-2

<LLD

<LLD 8.4 E-2 Xe-1332 4.9 E+1 1.2 E+2 8.6 E+2 1.0 E+3 Xe-133M 3.8 E-3

<LLD 6.9 E-2 7.3 E-2 Xe-1351 Ci 1.2 E+0 3.2 EO 3.1 E+1 3.5 E+1 Xe-135M

<LLD

<LLD

<LLD

<lLD Xe-138

<LLD

<LLD

<LLD

<LLD Ci Ci

.<LLD - No detectable activity above background 0569R 8

.t..a

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEDUS EFFLUENTS - ELEVATED RELEASE

~

8. Gaseous Effluents Released - Isotopes (continued)

-Isotopes Second Units April May June Quarter Released 2.

Iodine Releases Na-24 Ci

<LLD

<LLD

<LLD

<LLD Co-58 Ci 1.3 E-7

<LLD 8.8 E-9 1.4 E-7 Co-60 1.6 E-7 3.8 E-6 7.7 E-6 1.2 E-5 Ci 2

Br-82 7.2 E-7 1.2 E-6 1.6 E-6 3.5 E-6 Rb-88

<LLD

<LLD

<LLD

<LLD Ci 1-1 31 Ci 2.8 E-5 7.1 E-6 1.8 E-5 5.3 E-5 I-132

<LLD

<LLD

<LLD

<LLD I-133 2.4 E-6 2.5 E-6 1.6 E-5 2.1 E-5 I-134

<LLD

<LLD

<lLD

<LLD Cs-134

<LLD

<LLD

<LLD

<LLD I-135 Ci 3.9 E-7 8.0 E-7 1.2 E-6 2.4 E-6 Cs-136

<LLD

<LLD

<LLD

<LLD Cs-137 1.3 E-8 1.9 E-7 1.2 E-8 2.2 E-7 Cs-138

<LLD

<lLD

<LLD

<lLD Ce-144

<LLD

<LLD 8.3 E-7 8.3 E-7

<LLD - No detectable activity above background 0569R 9

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT.1985 GASEOUS EFFLUENTS - ELEVATED RELEASE B. Gaseous Effluents Released - Isotopes (continued)

Isotopes Second Units April May June Quarter Released 3.

Particulate Releases Na-24 Ci 7.3 E-7 4.2 E-7 3.1 E-7 1.5 E-6 Mn-54 7.2 E-7 3.2 E-6 2.9 E-9 3.9 E-6 Co-58 C1 2.3 E-6 4.5 E-6 8.2 E-8 6.9 E-6 Co-60 1.5 E-5 1.6 E-5 4.4 E-7 3.1 E-5 Ci Br-82 6.4 E-7

<LLD

<tLD 6.4 E-7 Rb-88 Ci 3.5 E-5 1.4 E-4 7.3 E-3 7.5 E-3 Sr-891 Sr-901 Sr-91 Ci

<LLD

<LLD

<lLD

<LLD Sr-92

<LLD

<LLD 2.5 E-7 2.5 E-7 Nb-95

<LLD

<LLD

<LLD

<LLD Ci Mo-99

<LLD

<LLD

<LLD

<LLD Tc-99M

<LLD

<LLD

<LLD

<LLD

<LLD - No detectable activity-above background 1 - Waiting for analysis results - Data will be presented in an errata to the Semi-Annual Report 0563R 10

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEOUS EFFLUENTS - ELEVATED RELEASE B. Gaseous Effluents Released - Isotopes (continued) l Second IS E'S Units April May June I Quarter Released 3.

Particulate Releases (continued) t' Ru-103 Ci

<LLD 1.9 E-8

<LLD 1.9 E-8 l

Aq-110M

<LLD

<LLD

<LLD

<LLD I

l i

Sb-122 Ci

<LLD

<LLD 3.6 E-8 3.6 E-8 I-131 1.5 E-8 1.3 E-8 1.5 E-8 4.3 E-8 I-132 5.0 E-9

<LLD

<LLD 5.0 E-9 Te-132

<LLD

<LLD 1.5 E-8 1.5 E-8 I-133 Ci 1.8 E-8 6.7 E-8 6.6 E-8 1.5 F-7 Cs-134 2.7 E-7 3.3 E-7 5.2 E-6 5.8 E-6 I-135

<LLD 6.4 E-8

<tLD 6.4 E-8 Cs-136 Ci

<LLD

<LLD

<LLD

<LLD Cs-137 3.5 E-6 8.9 E-7 5.0 E-6 9.4 E-6 Cs-138 7.7 E-7

<LLD 1.2 E-4 1.2 E-4 Ba-139

<LLD

<LLD

<lLD

<LLD Ba-140 Ci

<LLD

<LLD

<LLD

<LLD La-140

<lLD

<LLD 1.2 E-7 1.2 E-7 W-187 Ci

<LLD

<LLD 7.5 E-8 7.5 E-8 Bi-214

<LLD

<LLD

<LLD

<LLD Pb-214

<LLD

<LLD

<LLD

<LLD

<LLD - No detectable activity above background 0569R 11

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 1 C. Liquid Effluents Released - Summary Sheet first Units January February March Quarter 1.

Gross Radioactivity 1 i

a.

Total Release C1 4.2 E-3 No No 4.2 E-3 b.

Av C centration vC1/ml 1.2 E-9 Releases Releases 1.2 E-9 e

c.

Max. Concentration pCi/ml 6.0 E-9 This This 6.0 E-9 Released d.

%o Tec S

. Qtr.

4.2 E-2 Month Month 4.2 E-2 2.

Tritium l

l a.

Total Release Ci 4.7 E0 l

l 4.7 E0 b.

Avg. Concentration I

I pCi/ml 1.4 E-6 1.4 E-6 Released l

l c.

% of Tech. Spec.

I I

4.7 E-2 4.7 E-2 Limit (3 E-3 pCi/ml) l l

3.

Dissolved Noble Gases l

l a.

Total Release Ci 5.3 E-2 l

l 5.3 E-2 b.

Avg. Concentration I

I pC1/ml 1.6 E-8 1.6 E-8 Released l

l 4.

Gross Alpha Radioactivity I

I a.

Total Release Ci 5.3 E-6 l

l 5.3 E-6 b.

Avg. Concentration pC1/ml 1.6 E-12 1.6 E-12 Released l

l l

S.

Volume of Liquid Waste I

I Liters 1.6 E+5 1.6 E+5 to Discharge l

[

l l

6.

Volume of Dilution Water Liters 3.4 E+9 3.4 E+9 I

1 - Excludes Tritium, Alpha, and Dissolved Noble Gases

<LLD - No detectable activity above background 0569R 12

ZION STATION EFFLUENT AND WASTE DISPOSAL SEM1 ANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 1

0. Liquid Effluents Released - Isotopes fsotopej Units January February March Ou er Na-24 Ci

<lLD No No

<LLD Releases Releases This This Month Month l

I I

I Cr-51 Ci

<LLD

<LLO Mn-54

<LLD

<LLD Co-57

<LLD

<LLD Co-58 1.0 E-4 1.0 E-4 Fe-59

<LLD

<LLD I

l Co-60 Ci 2.2 E-3 2.2 E-3 1

I I

I I

Kr-85 Ci

<LLO

<lLD Kr-88

<LLD

<LLD Sr-891 I

i Sr-901 Sr-92

<LLD

<llD I

I I

I Nb-95 Ci

<LLO

<LLD Zr-95

<tLD

<LLO I

I

<LLD - No detectable activity above background 1 - Waiting for analysis results - Data will be presented in an errata to the Semi-Annual Report i

0569R 13

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 1 D. Liquid Effluents Released - Isotopes (continued) fsoopes Units January February March 0

r Ci No No Ru-105

<LLD Releases Releases

<LLD This This Month Month Aq-110M 5.6 E-5 l

l 5.6 E-5 I

I Sb-122 Ci

<lLD

<LLD Sb-124 8.0 E-5 8.0 E-5 Sb-125 2.7 E-4 2.7 E-4 I

I I-131 C) 2.7 E-4 2.7 E-4 I-133

<LLD

<LLD Xe-133 5.3 E-2 5.3 E-2 I

I Xe-133M Ci

<lLD

<llD Cs-134 6.1 E-4 6.1 E-4 I-134

<LLD

<LLD l

Xe-135

<LLD

<LLD I

I Cs-136 Ci

<tLD

<LLD Cs-137 6.6 E-4 6.6 E-4 Cs-138

<LLD

<LLD I

I I

I la-140 Ci

<LLO

<LLO W-187

<LLD

<LLD

<LLD - No detectable activity above background 0569R 14

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985

~

LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 2 C. Liquid Effluents Released - Summary Sheet First Units January February March Quarter I

1.

Gross Radioactivity 2 a.

Total Release Ci 1.1 E-1 1.5 E-1 1.2 E-1 3.8 E-1 b.

Avg. Concentration pCi/mi 1.1 E-9 1.5 E-9 1.2 E-9 1.3 EO Released c.

Max. Concentration pC1/ml 1.1 E-8 9.5 E-9 9.1 E-9 9.5 E-9 Released d.

% of Tech. Spec. Qtr.

3.8 E0 Limit (10 Ci) 1 2.

Tritium i

a.

Total Release Ci 7.9 E+1 4.3 E+1 7.5 E+1 2.0 E+2 b.

C centration pCi/mi 8.2 E-7 4.4 E-7 7.4 E-7 6.7 E-7 2.7 E-2 1.5 E-2 2.5 E-2 2.2 E-2 m

3 pCi/ml) 3.

Dissolved Noble Gases a.

Total Release Ci 7.5 E-1 3.2 E-1 2.2 E-1 1.3 E0 b.

C centration pCi/mi 7.8 E-9 3.3 E-9 2.2 E-9 4.4 E-9 4.

Gross Alpha Radioactivity a.

Total Release Ci 7.7 E-5 1.3 E-4 9.4 E-5 3.0 E-4 b.

C centration pCi/mi 8.0 E-13 1.3 E-12 9.3 E-13 1.0 E-12 5.

id Wste Liters 1.9 E*7 1.7 E+7 2.0 E+7 5.6 E+7 c rg 6.

Volume of Dilution Water Liters 9.6 E+10 9.7 E+10 1.0 E+11 2.9 E+11 1 - Excludes Tritium, Alpha, and Dissolved Noble Gases

<LLD - No detectable activity above background 2

0569R 15

~

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 2 D. Liquid Effluents Released - Isotopes fsoopes Units January February March 0

r Na-24 Ci

<LLD

<LLD 2.1 E-4 2.1 E-4 Ar-41

<LLD 3.8 E-5

<LLD 3.8 E-5 Cr-51 Ci

<LLD 5.1 E-3 8.4 E-3 1.4 E-2 Mn-54 3.1 E-5 6.8 E-5 3.2 E-4 4.2 E-4 Co-57

<lLD

<tLD

<llD

<LLD Co-58 9.6 E-3 3.7 E-2 3.4 E-2 8.1 E-2 Fe-59

<tLD

<LLD 4.0 E-5 4.0 E-5 Co-60 Ci 1.6 E-2 3.6 E-2 3.8 E-2 9.0 E-2 A

Kr-85 Ci

<tLD

<LLD

<LLD

<tLD I

Kr-88

<lLD

<llD

<LLD

<LLD l

Sr-891 Sr-901 Ci Sr-92

<LLD 1.5 E-5

<tLD 1.5 E-5 Nb-95 Ci-

<LLD

<LLD

<LLD

<tLD Zr-95

<tLD

<LLD 2.1 E-6 2.1 E-6

<LLD - No detectable activity above background 1 - Waiting for analysis results - Data will be presented in an errata to the Semi-Annual Report 0569R 16

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 2 D. Liquid Effluents Released - Isotopes (continued) fsoopes Units January February March Qua ter Ci Ru-105

<LLD

<LLD

<LLD

<LLD Aq-110M 4.9 E-4 2.2 E-3 1.6 E-3 4.3 E-3 Sb-122 Ci 1.1 E-4 1.1 E-3

<LLD 1.2 E-3 Sb-124 1.6 E-3 6.4 E-3 1.3 E-2 2.1 E-2 Sb-125 5.7 E-3 5.6 E-3 9.0 E-3 2.0 E-2 Xe-131M 8.5 E-3

<LLD

<LLD 8.5 E-3 1-131 Ci 2.1 E-2 9.4 E-3 4.4 E-3 3.5 E-2 1-133 8.7 E-4 5.9 E-5

<LLD 9.3 E-4 Xe-133 7.4 E-1 3.2 E-1 2.2 E-1 1.3 EO Xe-133M Ci 2.5 E-3

<LLD 1.7 E-3 4.2 E-3 4

{

Cs-134 2.3 E-2 2.3 E-2 4.4 E-3 5.0 E-2 I-134

<tLD

<LLD

<tLD

<LLD Xe-135 5.1 E-5

<lLD 1.8 E-4 2.3 E-4 Cs-136 Ci

<LLD 2.8 E-5

<LLD 2.8 E-5 Cs-137 2.3 E-2 2.4 E-2 4.1 E-3 5.1 E-2 Cs-138 2.3 E-4

<lLD 3.3 E-3 3.5 E-3 La-140 Ci 2.0 E-4 2.4 E-4

<LLD 4.4 E-4

)

W-187

<LLD

<LLD

<lLD

<LLD

<LLD - No detectable activity above background 0569R 17

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 1 C. Liquid Effluents Released - Summary Sheet Second Units April May June Quarter 1.

Gross Radioactivity 2 a.

Total Release Ci No No No No L

C centration pCi/ml Releases Releases Releases Releases c.

Max. Concentration pCi/ml This This This This Released d.

%o fec. S

. Qtr.

Month Month Month Quarter l

l 2.

Tritium a.

Total Release Ci l

l l

l pCi/ml l

l l

l b.

Avg. Concentration Released t

I c.

% of Tech. Spec.

Limit (3 E-3 pCi/ml) l l

l l

3.

Dissolved Noble Gases a.

Total Release Ci b.

Avg. Concentration pCi/ml l

l l

l Released l

l l

l 4.

Gross Alpha Radioactivity l

l l

l a.

Total Release Ci l

b.

Avg. Concentration Ci/ml Released l

l l

l I

I I

I I

I I

I S.

Volume of Liquid Waste Liters l

l l

l to Discharge l

l i

i 6.

Volume of Dilution Water Liters l

l l

l 1 - Excludes Tritium, Alpha, and Dissolved Noble Gases

<LLO - No detectable activity above backgropnd 4

0569R 18 1

ZION STATION EFFLUENT AND WASTE DISPOSAL SENIANNUAL REPORT 1985 LIQUID EFFLUENTS i

UNIT 1 D.

Liquid Effluents Released - Isotopes i

Isotopes b'C Ud Units April May June Quarter i

Released i

Na-24 Ci No No No No Releases Releases Releases Releases This This This This Month Month Month Quarter i

t t

I I

I I

I l

Cr-51 Ci Mn-54 Co-57 Co-58 Fe-59 I

I I

I 1

I I

l l

Co-60 Ci i

I I

I I

I I

I I

Kr-85 Ci I

l l

i I

i i

1 l

Kr-88 I

l l

l l

l l

l 1

I Sr-892 i

--l

--l

--l

--l Sr-901 Ci e.

i.

i.

i 3

Sr-92 I

I I

i 1

1 I

I I

J l

l l

l I

I I

I I

I I

I Nb-95 Ci Zr-95 I

i i

l n

l I

'l 1

j

<LLO - No detectable activity above background t-1 - Waiting for analysis results - Data will l

l be presented in an errata to the Semi-Annual Report l

]

0569R 19

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 1 D.

Liquid Effluents Released - Isotopes (continued)

Is pes Second Units April May June Released Quarter Ci No No No No l

Ru-105 Releases Releases Releases Releases This This This This Month Month Month Quarter i

Aa-110M i

i i

i I

I I

I Sb-122 Ci I

i l

l Sb-124 I

l l

l Sb-125 I

I l

l I

l l

l l

l l

l l

+

I I

I I

I-131 Ci i

I-133 I

Xe-133 l

i i

i

)

1 I

I Xe-133M Ci i

l l

l Cs-134 I

I l

I-134 l

l l

l I

I l

l l

Xe-135 I

I l

l j

l l

l l

Cs-136 Ci Cs-137 l

i Cs-138 I

i l

i i

i j

l 1

1 I

La-140 Ci l

I i

I I

I I

I I

I I

I l

i I

I j

W-187 I

I I

l

<LLD - No detectable activity above background 0569R 20

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT 2 C. Liquid Ef fluents Released - Sununary Sheet Second Units April May June Quarter

1. Gross Radioactivity 1 a.

Total Release C1 1.6 E-1 2.7 E-1 1.9 E-1 6.2 E-1 b.

Avg. Concentration pC1/ml 1.7 E-9 2.5 E-9 1.6 E-9 1.9 E-9 Released c.

Max. Concentration pCi/ml 1.1 E-8 1.1 E-8 1.2 E-8 1.2 E-8 Released d.

% of Tech. Spec. Qtr.

6.2 E0 limit (10 C1)

2. Tritium a.

Total Release Ci 3.5 E+1 7.3 E+1 3.4 E+1 1.4 E+2 b.

ncentration pCi/ml 3.8 E-7 6.7 E-7 2.8 E-7 4.4 E-7 c.

% of Tech. Spec.

Limit (3 E-3 pC1/ml) 1.3 E-2 2.2 E-2 9.3 E-3 1.5 E-2

3. Dissolved Noble Gases a.

Total Release C1 4.6 E-2 2.1 E-1 4.8 E-1 7.4 E-1 b.

C centration pCi/ml 5.0 E-10 1.9 E-9 4.0 E-9 2.1 E-9

4. Gross Alpha Radioactivity a.

Total Release Ci 9.9 E-5 8.4 E-5 1.7 E-4 3.5 E-4 b.

C centration pCi/ml 1.1 E-12

't.7 E-13 1.4 E-12 1.1 E-12 5.

Volume of Liquid Waste Liters 2.7 E+7 2.9 E+7 1.9 E+7 7.5 E+7 to Discharge 6.

Volume of Dilution Water Liters 9.3 E+10 1.1 E+11 1.2 E+11 3.2 E+11 1 - Excludes Tritium, Alpha, and Dissolved Noble Gases

<LLO - No detectable activity above background l

0569R 21

ZION STATION i

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 2 1

D.

Liquid Effluents Released - Isotopes 4

Isotopes Second Units April May June Quarter Released Na-24 Ci 4.7 E-4 1.2 E-4 6.4 E-4 1.2 E-3 i

Cr-51 Ci 1.1 E-2 1.6 E-2 6.8 E-3 3.4 E-2 Mn-54 8.5 E-5 7.3 E-4 8.7 E-4 1.7 E-3 Co-57

<LLO

<LLD

<tLD

<LLD Co-58 5.3 E-2 3.9 E-2 3.5 E-2 1.3 E-1 i

Fe-59

<ll0

<tLD

<LLD

<LLO i

l l

Co-60 Ci 3.2 E-2 7.6 E-2 4.8 E-2 1.6 E-1 i

i P

Kr-85 C1

<tLD

<lLD

<LLO

<lLD Kr-88

<tLD

<LLD

<LLD

<llD I

i Sr-891 Sr-901 Ci dr-vz

<ttu

<ttu

<ttu

<ttu 4

t h

Nb-95 Ci 2.0 E-4

-7.0 E-5 6.2 E-5 3.3 E-4 Zr-95

<LLO 1.2 E-3 3.8 E-4 1.6 E-3 1

<LLD - No detectable activity above background 1 - Waiting for analysis results - Data will be presented in an errata to the Semi-Annual Report 0569R 22

. - -. =.

ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1985 LIQUID EFFLUENTS UNIT 2 D.

Liquid Effluents Released - Isotopes (continued) i Isotopes Secord Units April May June Released Quarter Ci Ru-105

<LLO

<LLD

<LLO

<LLO

__ Aa-110M 3.9 E-3 4.9 E-3 3.4 E-3 1.2 E-2 Sb-122 C1

<lLD

<tLD 1.0 E-4 1.0 E-4 Sb-124 2.2 E-2 1.8 E-2 1.1 E-2 5.1 E-2 Sb-125 1.3 E-2 1.6 E-2 1.5 E-2 4.4 E-2 i

l l

J I-131 C) 1.1 E-2 7.6 E-3 1.8 E-3 2.0 E-2 I-133

<tLD

<LLD

<LLO

<tLD

[

Xe-133 4.6 E-2 2.1 E-1 4.7 E-1 7.3 E-1 i

Xe-133M Ci

<LLO 1.4 E-3 5.1 E-3 6.5 E-3 l

Cs-134 2.3 E-3 4.2 E-2 3.1 E-2 7.5 E-2 I-134

<LLO

<tLD

<LLO

<lLD j

Xe-135

<tLD 4.7 E-5 3.9 E-3 3.9 E-3 l

Cs-136 Ci

<LLO 2.4 E-4

<lLD 2.7 E-4 Cs-137 2.7 E-3 4.1 E-2 3.5 E-2 7.9 E-2 4

i Cs-138 4.0 E-3 3.8 E-3 3.4 E-3 1.1 E-2 i

La-140 C1

<LLO

<LLO

<LLO

<tLD

__ W-187 (LLO

<LLD

<tLD

<LLD

<LLO - No detectable activity above background i

l 0569R 23

f ZION GENERATING STATION UNIT 1/2 Month January Year 1985 SOLID RADI0 ACTIVE WASTE (Tech Spec 6.6A39)

Volume (ft*)

Volume (ft*)

M1111 curies M1111 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month 02 1/7/85 Uncemented Drums 420.00 420.00 78.456 78.456 01 i

1/8/85 Uncemented Drums and 80x 670.80 1090.80 1437.037 1515.493 05 1/15/85 Uncemented Drums 105.00 1195.80 5159.66 6675.153 04

-1/16/85 Solidified 011 Liners 340.00 1535.80 0.022 6675.175 03 1/17/85 Dewatered Filters and Sludge 105.00 1640.80 9295.12 15970.295 06

_1/21/85 Solidified Cask 170.00 1810.80 11334.19 27304.485 07 I

1/24/85 Solidified Cask 170.00 1980.80 3076.23 30380.715 08 1/28/85 Solidified Cask 80.00 2060.80 168.29 30549.005 09 1 /31/85 Uncemented Drums 557.20 2618.00 298.772 30847.777 i

l l_

i MONTH TOTAL 30847.777 0571R l

ZION GENERATING STATION UNIT 1/2 Month February Year 1985 SOLID RADI0 ACTIVE WASTE (Tech Spec 6.6A39)

Volume (ft*)

Volume (ft*)

M1111curles M1111 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month 10 2/8/85 Solidified Cask 80.00 80.00 216.90 216.90 12 2/19/85 Uncemented Drums and Box 652.40 732.40 913.564 1130.464 2/22/85 Dewatered Filters in HIC 76.00 808.40 2117.7104 3248.1744 13 2/26/85 Solidified Cask _

170.00 978.40 1753.90 5002.0744 t

l I

I l

l MONTH TOTAL 5002.0744 l

0571R l

. _,. -~. -.

l l

ZION GENERATING STATION UNIT 1/2 i

Month March Year 1985 i

SOLID RADIDACTIVE WASTE (Tech Spec 6.6A3g)

Volume (ft*)

Volume (ft8)

M1111 curies Mil 11 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month I4 l

3/7/85 Solidified Oil Liners 340.00 340.00 0.056 0.056 15 3/12/85 Solidified 011 Liners 340.00 680.00 0.054 0.11 16 3/15/85 Uncemented Drums and 80x 672.80 1352.80 228.36 228.47 I

3/22/85 Solidified Cask 170.00 1522.80 890.74 1119.21 3/28/85 Dewatered Filters in HIC 76.00 1598.80 74417.19 75536.40 1

4 5

1 i

1 I

I

[

i l

1 i

j MONTH TOTAL 75536.40

)

j 0571R i

ZION GENERATING STATION UNIT 1/2 Month April Year 1985 SOLID RADIDACTIVE WASTE (le:h Spec 6.6A39)

Volume (ft*)

Volume (ft')

M1111 curies M1111 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month II 4/10/85 Solidified Cask 170.00 170.00 1614.68 1614.68 20 4/17/85 Solidified Cask 170.00 340.00 36295.49 37910.17 4/22/85 Uncemented Drums and Rox 720.80 1060.80 328.759 38238.929 f

l MONfH TOTAL 38238.929 0571R l

ZlDN GENERATING STATION UNIT 1/2 Month May Year 1985 SOLIO RADIDACTIVE WASTE (Tech Spec 6.6A3g)

Volume (ft*)

Volume (ft")

M1111 curies M1111 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month 5/1/85 Solidified Cask 80.00 80.00 140355.372 140355.372 3

5/2/85 Solidified Cask 170.00 250.00 19128.45 159483.822 5/6/85 Solidified Cask 85.00 335.00 13499.391 172983.213 25 5/10/85 Uncemented Drums and Sox 682.40 1017.40 292.194 173275.407 28 5/20/85 Solidified Cask 170.00 1187.40 5465.43 178740.837 5/21/85 Dewatered Filters in HIC 76.00 1263.40 10716.35 189457.187 27 5/24/85 Uncemented Drums 634.80 1898.20 387.209 189844.396

-__5/31/85 Uncemented Drums 600.00 2498.20 620.238 190464.634 29 PONIH TOTAL 190464.634 0571R

___.__________________.-___.._____.._m i

ZION GENERATING STATION UNIT 1/2 Month June Year 1985 I

SOLID RADI0 ACTIVE WASTE (Tech Spec 6.6A39)

Volume (ft*)

Volume (ft*)

Millicuries M1111 curies Date Disposition of Material Per Shipment Per Month Per Shipment Per Month 31 6/4/85 Solidified Cask 170.03 170.00 22977.96 22977.96 6/11/85 Uncemented Drums 532.50 702.50 487.746 23465.706 32 6/19/85 Solidtfied Cask 170.00 872.50 7276.57 30742.276 6/21/85 Uncemented Drums 600.00 1472.50 570.75 31313.026 34 6/25/85 Solidified Cask 170.00 1642.50 2711.71 34024.736 35 6/26/85 Solidified Cask 85.00 1727.50 242.74 34267.476 s

t i

I MONTH TOTAL 34267.476 0571R

q i

ZION UNIT ONE AND U10 HAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 CURRENT CURRENT 1ST PREV 2ND PREV 3RD FF.EV ANNUAL TYPE PERIOD QUARTER QUARTER QUARTER GUARTER 1/85-3/85 10/84-12/84 7/84-9/84 4/84-6/84 OAMMA AIR 5.01E-02 5.01E-02 4.83E-02 1.30E-01 2.61E-02 2.55E-01 (MRAD)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

BETA AIR 3.24E-01 3.24E-01 1.72E-01 4.11E-01 1.34E-01 1.04EF00 (MRAD)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

TOT. BODY 1.25E-02 1.2SE-02 2.06E-02 5.86E-02 8.75E-03 1.00E-01 (MREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

SKIN 1.50E-01 1.50E-01 1 05E-01 2.42E-01 7.35E-02 5.91E-01 (HREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

ORGAN 3.73E-03 3.73E-03 4.17E-03 1.79E-02 3.55E-03 3.13E-02 (MREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

THYROID THYROID THYROID THYROID THYROID THYROID LAST PERIOD OF RELEASE - 10/ 1/84 TO 12/31/04 CALCULATED 03/19/85 THIS REPORT CONTAINS RELEASES FOR THE CURRENT GUARTER ONLY COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

OTRLY CURR GTR 1ST PREV 2ND PREV 3RD PREV YRLY

% OF OBJ 1/85-10/04-7/84-4/84-OBJ APP.I-3/85 12/04 9/84 6/84 OAMMA AIR (MRAD) 5.0 1.00 0.97 2.60 0.52 10.0 2.55 BETA AIR (MRAD) 10.0 3.24 1.72 4.11 1.34 20.0 5.21 TOT. BODY (MREM) 2.5 0.50 0.02 2.34 0.35 5.0 2.01' SKIN (MREM) 7.5 2.00 1.40 3.50 0.98 15.0 3.94 ORGAN (MREM) 7.5 0.05 0.06 0.27 0.05 15.0 0.21 THYROID THYROID THYROID THYROID THYROID RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1905 L

~

ZION UllIT ONE AND 'I"c?O MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE -

4/ 1/85 TO 6/30/85 CALCULATED 08/13/85 CURRENT CURRENT 1ST PREV 2ND PREV 3RD PREV ANNUAL TYPE PERIOD QUARTER QUARTER QUARTER QUARTER 4/85-6/85 1/85-3/85 10/84-12/84 7/84-9/84 OAMMA AIR 4.03E-02 4.03E-02 5.01E-02 4.83E-02 1.30E-01 2.69E-01 (MRAD)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

BETA AIR 2.32E-01 2.32E-01 3.24E-01 1.72E-01 4.11E-01 1.14E+00 (MRAD)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

TOT. BODY 1.19E-02 1.19E-02 1.25E-02 2.06E-02 5.86E-02 1.04E-01 (MREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

SKIN 1.11E-01 1.11E-01 1.50E-01 1.05E-01 2.62E-01 6.29E-01 (MREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

ORGAN 3.28E-04 3.28E-04 3.73E-03 4.17E-03 1.99E-02 2.81E-02 (MREM)

(N

)

(N

)

(N

)

(N

)

(N

)

(N

)

THYROID THYROID THYROID THYROID THYROID THYROID LAST PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 THIS REPORT CONTAINS RELEASES FOR THE CURRElli OUARTER ONLY COMPLIANCE STATUS - 10 CFR 50 APP. I

- - -- - - - - - - - - - - - % O F A F P I.

QTRLY CURR QTR 1ST PREV 2ND PREV 3RD PREV YRLY

% OF OBJ 4/85-1/85-10/84-7/84-OBJ APP.I.

6/85 3/85 12/84 9/84 GAMMA AIR (MRAD) 5.0 0.81 1.00 0.97 2.60 10.0 2.69 BETA AIR (MRAD) 10.0 2.32 3.24 1.72 4.11 20.0 5.70 TOT. BODY (MREM) 2.5 0.48 0.50 0.82 2.34 5.0 2.07 SKIN (MREM) 7.5 1.49 2.00 1.40 3.50 15.0 4.19 ORGAN (MHmh 7.5 0.00 0.05 0.04 0.27 15.0 0.19 THYROID THYROID THYROID THYROID THYROID RESULTS BASED UP0ll ODCM REVISION 10 UPDATE DM000 11 ARCH 1980 t

~=.

ZION UNIT ONE i

HAXIMUM l'0SES-(MREM) RESULTING FROM' LIQUID EFFLUENTS PERIOD OF RELEASE -

1/ 1/85 TO -3/31/85 CALCULATED 08/13/85

  • CURRENT CURRENT iST PREV 2ND PREV 3RD PREV ANNUAL DOSE' TYPE PERIOD QUARTER QUARTER-GUARTER QUARTER l

1/85-3/85 10/84-12/84 7/84 9/84 4/84-6/84

!~

TOTAL 7 19E-05 7.19E-05 0.00E-01 0.00E-01 0.00E-01 7.19E-05 BODY l

INTERNAL 2.26E-04 2.26E-04 0.00E-01 0.00E-01 0.00E-01 2.26E-04 4-ORGAN THYRDID THYROID THYROID i

I

  • LAST PERIOD OF RELEASE -

0/ O/ 0 TO 0/ O/ 0 CALCULATED j

THIS REPORT IS-BASED ON CURRENT QUARTER RELEASES i

COMPLIANCE. STATUS - 10 CFR 50 APP. I I

i


 % OF APP I.

QTRLY 'CURR QTR IST PREV 2ND PREV 3RD PREV YRLY

% OF I

OBJ 1/SS-10/84-7/84-4/84-OBJ APP.I 3/35 12/84 9/84 6/84 i

i TOTAL BODY (MREM) 1.5 0.00 00.00 00.00 00.00 3.0 0.00 j

CRIT. ORGAN (MREM) 5.0 0.'00 00.00 00.00 00.00 10.0 0.00 -

l i

1 THYROID.

THYROID ;

1 i

RESULTS BASED UPON ODCM REVISION 10 f

UPDATE DM000

.1 ARCH 1985

?

I j

I.

f i

4

~

ZION UNIT ONE PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM $

PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 CURRENT CURRENT IST PREV 2ND PREV 3RD PREV ANNUAL DOSE TYPE PERIOD QUARTER GUARTER QUARTER QUARTER 1/85-3/85 10/84-12/84 7/84-9/84 4/84-6/84 TOTAL 5.79E-03 5.79L-03 0.00E-01 0.00E-01 0.00E-01 5.79E-03 BODY INTERNAL 2.26E-02 2.26E-02 0.00E-01 0.00E-01 0.00E-01

2. 26E -'02 ORGAN THYROID THYROID THYROID
  • LAST PERIOD OF RELEASE -

0/ 0/ 0 TO 0/ O/ 0 CALCULATED THIS REPORT IS BASED ON CURRENT 00ARTER RELEASES COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.145 BODY INTERNAL 4.0 (MREM) 0.564 i

ORGAN THYROID THIS CALCULATION OF LOSE IS BASED ON TECHNIQUES DESCRIBED IN THE

' COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141. A PROJECTED DOSE OF 2 MREM USING CECO TECHNIQUES IS APPROXIMATELY 4 MREM USINO EPA METHODS.

RESULTS BASED UPON ODCM REVISION 10 UPDATE DH000 MARCH 1985

\\

i

4 ZION UNIT ONE MAXIMUM DOSES'(MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE -

4/ 1/S5 TO 6/30/85 CALCULATED 08/13/85

  • CURRENT CURRENT 1ST PREV 2ND PREV 3RD PREV ANNUAL DOLE TYPE PERIOD QUARTER QUARTER QUARTER QUARTER 4/85-6/85 1/85-3/85 10/84-12/84 7/84-9/84 TOTAL 0.00E-01 0.00E-01 7.19E-05 0.00E-01 0.00E-01 7.17E-05 BODY INTERNAL 0.00E-01 0.00E-01 2.26E-04 0.00E-01 0.00E-01 2.26E-04 ORGAN THYROID THYROID
  • LAST PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

OTRLY~ CURR OTR 1ST PREV 2ND PREV 3RD PREV YRLY

% OF OBJ 4/85-1/85-10/84-7/84-DBJ APP.I 6/85 3/85 12/04 9/84 TOTAL BODY (MREM) 1.5 00.00 0.00 00.00 00.00 3.0 0.00 CRIT. ORGAN (MREM) 5.0 00.00 0.00 00.00 00.00 10.0 0.00 THYROID THYROID RESULTS BASED UPON ODCM REVISION 10' UPDATE DM000 MARCH 1985 l

i e

/

P d

k

)

\\,

l,

)

s

ZION UNIT ONE t

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE -

4/ 1/85 TO 6/30/85 CALCULATED 08/13/85 CURRENT CURRENT iST PREV 2ND PREV 3RD PREV ANNUAL DOSE TYPE PERIOD QUARTER QUARTER QUARTER QUARTER 4/85-6/85 1/85-3/85 10/84-12/84 7/84-9/84 TOTAL 0.00E-01 0.00E-01 5.79E-03 0.00E-01 0.00E-01 5.79E-03 BODY INTERNAL 0.00E-01 0.00E-01 2.26E-02 0.00E-01 0.00E-01 2.26E-02 ORGAN l

THYROID THYROID 1

  • LAST PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.145 BODY INTERNAL 4.0 (MREM) 0.564 ORGAN THYROID THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISDN OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM-THOSE DESCRIBED IN 40 CFR 141. A PROJECTED DOSE OF 2 MREM USING CECO TECHNIQUES IS APPROXIMATELY 4 MREM USING EPA METHODS.

RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1985

ZION UNIT TWO MAXIMUM DOSES (MREM) RESULTING FROM LIQUID EFFLUENTS PERIOD OF RELEASE -

1/ 1/85 TO 3/31/83 CALCULATED 08/13/85

  • CURRENT CURRENT 1ST PREV 2ND PREV 3RD PREV ANNUAL DOSE TYPE PERIOD QUARTER QUARTER QUARTER QUARTER 1/85-3/95 10/84-12/84 7/84-9/84 4/84-6/84 TOTAL 1.17E-03 1.17E-03 0.00E-01 0.00E-01 0.00E-01 1.17E-03 BODY INTERNAL 1.57E-03 1.57E-03 0.00E-01 0.00E-01 0.00E-01 1.57E-03 ORGAN LIVER LIVER LIVER
  • LAST PERIOD OF RELEASE -

0/ O/ 0 TO 0/ 0/ 0 CALCULATED

~

THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

QTRLY CURR GTR IST PREV 2ND PREV 3RD PREV YRLY

% OF OBJ 1/85-10/84-7/84-4/84-OBJ APP.I 3/85 12/84 9/84 4/84 TOTAL BODY (MREM) 1.5 0.08 00.00 00.00 00.00 3.0 0.04 CRIT. ORGAN (MREM) 5.0 0.03 00.00 00.00 00.00 10.0 0.02 LIVER LIVER RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1985 I

l l

l

^

ZION UNIT TWO PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 CURRENT CURRENT 1ST PREV 2ND PREV 3RD PREV ANNUAL DOSE TYPE PERIOD QUARTER DUARTER GUARTER DUARTER 1/85-3/85 10/84-12/84 7/84-9/84 4/34-6/84 TOTAL 5.31E-03 5.31E-03 0.00E-01 0.00E-01 0.00E-01 5.31E-03 BODY INTERNAL 3.44E-02 3.44E-02 0.00E-01 0.00E-01 0.00E-01 3.44E-02 ORGAN THYROID THYROID THYROID

  • LAST PERIOD OF RELEASE -

0/ 0/ 0 TO 0/ O/ 0 CALCULATED THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.133 BODY INTERNAL 4.0 (MREM) 0.861 ORGAN THYROID THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141. A PROJECTED DOSE OF 2 MREN USING CECO TECHNIGUES IS APPROXIMATELY 4 MREM USING EPA METHODS.

RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1983 l

I ZION UNIT TWO MAXIMUM DOSES (MREM) RESULTINO FROM LIQUID EFFLUENTS PERIOD OF RELEASE -

4/ 1/85 TO 6/30/85 CALCULATED 08/13/85

  • o CURRENT CURRENT iST PREV 2ND PREV 3RD FREV ANNUAL DOSE TYPE PERIOD GUARTER QUARTER QUARTER QUARTER

'4/85-6/85 1/83-3/85 10/34-12/84 7/84-9/84 TOTAL 1.78E-03 1.78E-03 1.17E-03 0.00E-01 0.00E-01 2.95E-03 BODY INTERNAL 2.38E-03 2.38E-03 1.57E-03 0.00E-01 0.00E-01 3.94E-03 ORGAN LIVER LIVER LIVER LIVER

  • LAST PERIOD OF RELEASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

QTRLY CURR QTR 1ST PREV 2ND PREV 3RD PREV YRLY

% OF OBJ 4/85-1/85-10/84-7/84-OBJ APP.I 4/85 3/85 12/84 9/84 TOTAL BODY (MREM) 1.5 0.12 0.08 00.00 00.00 3.0 0.10 CRIT. ORGAN (MREM) 5.0 0.05 0.03 00.00 00.00 10.0 0.04 LIVER LIVER LIVER RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1985

e ZION UNI,T TWp PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE -

4/ 1/85 TO 6/30/85 CALCULATED 08/13/85 CURRENT CURRENT IST PREV 2ND PREV 3RD PREV ANNUAL DOSE TYPE PERIOD QUARTER QUARTER QUARTER QUARTER 4/85-6/85 1/85-3/85 10/84-12/84 7/84-9/84 TOTAL 7.39E-03 7.39E-03 5.31E-03 0.00E-01 0.00E-01 1.27E-02 BODY INTERNAL 1.79E-02 1.79E-02 3.44E-02 0.00E-01 0.00E-01 5.24E-02 ORGAN THYROID THYROID THYROID THYROID

  • LAST PERIOD OF RELE'ASE -

1/ 1/85 TO 3/31/85 CALCULATED 08/13/85 THIS REPORT IS BASED ON CURRENT GUARTER RELEASES COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 (MREM) 0.318 BODY INTERNAL 4.0 (MREM) 1.309 ORGAN THYROID THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141. A PROJECTED DOSE OF 2 MREM USING CECO TECHNIQUES IS APPROXIMATELY 4 MREM USING EPA METHODS.

RESULTS BASED UPON ODCM REVISION 10 UPDATE DM000 MARCH 1985