"C U3"' I SAFETY EVALUATION REPORT FOR GENERIC LE iith 83-28, ITEM 1.1 - F051-TRIP REVIEW (FRUbkAl; OESCRIPTIOh AhD PROCEUURE)

OCONEE hucLEAR STATION, UhITS 1, 2 AND 3 LOCKEl hub..

50-269/270/287 I.

INTROLUCTION On February 25, 1983, both of the scram circuit breakers at Unit 1 of the Saler huclear Power Plant failed to open upon an automatic reacter trip signal from the reactor protection system. This incident occurred during the plant start-up and the reactor was tripped manually by the operator about 30 seconds after the initiation of the automatic trip signal. The failure of the circuit breakers has been determined to be related to the sticking of the under voltage trip attachment. Prior to this incident, on February 22, 1983, at Unit 1 of the Salem Nuclear Power Plant, an automatic trip signal was generated based on steam generator low-low level during plant start-up.

In this case, the reacter was tripped manually by the operator almost coincicentally with the autcmatic trip. Following these incidents, on February 28, 1983, the NkC Executive Director for Operations (EDO), directed the staff to investigate and report on the generic implications of these occurrences at Unit 1 of the Salem Nuclear Power Plant. The results of the staff's inquiry into the generic implications of the Salem unit incidents are reported in NUREG-1000 " Generic Implications of ATWS Events at the Salen Nuclear Power Plant." As a result of this investigation, the Comission (hRC) requested (by Generic Letter 83-28 dated July 8,1982) all licensees of operating reactors, applicants for an operating license, and holders of construction permits to respond to certain generic concerns. These concerns are categorized into four areas: (1) Post-Trip Review, (2) Equipment Classification and Vendor Interface, (3) Post-Maintenance Testing, and (4) Reactor Trip System Reliability Improvements.

The first acticn item, Post-Trip Review, consists of Action item 1.1, "Progran Description and Procedure" and Action Item 1.2. " Data and Information Capebility." This safety evaluation report (SER) addresses Action Item 1.1 only.

G509050349 850 {9 PDR ADOCK 0 PDR P

I

.p.

II. REVIEk' GUIDELINES The following review guidelines were developed after initial evaluation of the various utility respenses to item 1.1 of Generic Letter 63-28 and incorporate the best features of these submittals. As such, these review guidelines in effect represent a " good practices" approach to post-trip review. We have reviewed the licensee's response to item 1.1 against these guidelines:

A.

The licensee or applicant should have systematic safety assessment procedures established that will ensure that the following restart criteria are cet before restart is authorized.

~

The post-trip review team has determined the root cause and sequence of events resulting in the plant trip.

Near term corrective actions have been taken tc remcdy the caust of the trip.

The post-trip review team has performed an analysis and determined that the major safety systems responded to the event within specified limits of the primary system parameters.

The post-trip review has not resulted in the discovery of a potentia 1' safety concern (e.g., the root cause of the event occurs with a frequency significantly larger than expected).

If any of the above restart criteria are not met, then an independent assessment of the event is performed by the Plant Operations Review Comittee (PORC), or another designa.ted group with similar authority and experience.

l l

l t

l

i 3

B.

The responsibilities and authorities of the personnel who will perform the review and analysis should be well defined.

The post-trip review team leader shoulc be a member of plant management at the shift supervisor level or above and should hold or should have held an SRO license on the plant. The team leader should be charged with overall responsibility for directing the post-trip review, including data gathering and data assessment and he/she should have the necessary authority to obtain all personnel and data needed for the post-trip review.

A second person on the review team shculd be an STA or should hold a relevant engineering degree with special transient analysis training.

The team leac'er and the STA (Er.gineer) should be responsible to concur on a decision / recommendation to restart the plant. A nonconcurrence from either of these persons should be sufficient to prevent restart until the trip has been reviewed by the P0iic or equivalent organization.

C.

The licensee or applicant should indicate that the plant response to the trip event will be evaluated and a determination made as to whether the plant response was within acceptable limits. The evaluation should include:

A verification of the proper operation of plant systems anc equipment by comparison of the pertinent data obtained during the post-trip review to the applicable data provided in the FSAR.

j An analysis of the secuence of events to verify the proper functioning of safety related and other important equipment. Where possible, comparisons with previous similar events should be u de.

1

. D.

The licensee or applicant shculd have procedures to ensure that all physical evidence necessary for an independent assessment is preserved.

E.

Each licensee or applicant shculd provide iri its submittel, copies of the plant procedures which contain the information required in Itens A through D.

As a minimum, these should include the following:

The criteria for determining the acceptability of restart The cualificaticns, responsibilities and authorities of key personnel involved in the post-trip review process The methocs and criteria for deterniining whether the plant variables and system responses were within the limits as described in the FSAR The criteria for determining the need for an independent review.

III. EVALUATION AND CONCLUSION By letter dated havember 4, 1983, the licensee of Oconee Nuclear Station, Units 1, 2 and 3, provided information regarding its Post-Trip Review Program and Procedures. We have evaluated the licensee's program and procedures against the review guidelines developed as described in Section II. A brief cescription of the licensee's response and the staff's evaluation of the response against each of the review guidelines is provided below:

A.

The licensee has established the criteria for determining the acceptability of restart. We find that the licensee's crit.eria conform with the guicelines as described in the above Section II.A, and, therefore, are acceptable.

o -

l I

B.

The cualifications, responsit,ilities and authorities of the personnel who will perform the review and analysis have been clearly described.

We have reviewed the licensee's chain of command for responsibility for post-trip review and evaluation, and find it acceptable.

I C.

With regard to the methods and criteria for comparing the event information with known or expected plant behavior, the licensee has indicated that the post-trip review program will include an assessment of the plant trainsient behavior that identifies any deviations from expected plant performance and an assessirent of the performance of protection and engineered safety systems identifying any malfunctions or failures to perform as expected. We find that these actions to be taken by the licensee conform to the guidelines as described in the above Section II.C.

D.

With regard to the criteria for determining the need for independent i

assessment of an event, the licensee nas indicated that if any of the criteria for restart are not net, an independent assessment of the event will be performed. In addition, the licensee has established procedures to ensure that all physical evidence necessary for an independent assessment is preserved. We find that these actions to be taken by the licensee conform to the guidelines as described in the above Sections II.A. and D.

E.

The licensee has provided for our review a systematic safety assessment program to assess unscheduled reactor trips. Based on our review, we find this program acceptable.

Based on our review, we conclude that the licensee's Post-Trip Review Program and Procedures for Oconee Nuclear Station, Units 1, 2 ar.d 3, are. acceptable.

Dated:

i Principal Contribution:

D. Shum

(

..-