Forwards Insp Rept 50-160/85-02 on 850708-16 & Notices of Violation & Deviation.Identification & Remedy of Root Cause of Fifth Violation Stressed
Date released: 05/27/2020 Download: ML20134N231


Insp Rept 50-160/85-02 on 850708-16.Violation Noted:Failure to Follow Procedures & Prescribe Proper Methods for Procedure Change When Needed & Inadequate Procedures for Performance of ECCS Surveillance Requirement
ML20134N244
Person / Time
Site: Neely Research Reactor
Issue date: 08/12/1985
From: David Loveless, Wilson B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20134N244 (11)
Notice of Deviation from Insp on 850708-16
ML20134N240
Person / Time
Site: Neely Research Reactor
Issue date: 08/21/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20134N240 (1)
Notice of Violation from Insp on 850708-16
ML20134N237
Person / Time
Site: Neely Research Reactor
Issue date: 08/21/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20134N237 (2)
Forwards Insp Rept 50-160/85-02 on 850708-16 & Notices of Violation & Deviation.Identification & Remedy of Root Cause of Fifth Violation Stressed
ML20134N230
Person / Time
Site: Neely Research Reactor
Issue date: 08/21/1985
From: Walker R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: KARAM R A
Neely Research Reactor, ATLANTA, GA
References
Download: ML20134N230 (3)