Proposed Tech Specs,Submitting follow-up Info Re Snubbers TS Bases Change
ML20134M052
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 02/11/1997
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20134M049 List:
References
NUDOCS 9702200075
Download: ML20134M052 (4)


Text

.

?

Pronosed ANO-2 Technical Specification Bases Changes 9702200075 970211

^

PDR ADOCK 05000368 P

POR

m.

m._ _ __ _. m. _..

l t

i PLANT SYSTEMS BASES L

1

..To previde further assurance of snubber reliability, a representa-tive sample of the installed snubbers will be functionally tested at 18 month intervals.

("Once each refueling shutdown" as indicated in the specification defines the frequency, not the operational mode required for l

performance of functional testing of snubbers.)

Alternatively, snubbers may be tested on-line.

These tests will include stroking of the snubbers to verify proper piston movement, lock-up and bleed. Observed failures of i

these sample snubbers will require functional testing of additional units.

To minimize personnel exposures, snubters installed in areas which have high radiation fields during shutdown or a especially difficult to remove locations may be exempted from these functional testing requirements l

provided the OPERABILITY of these snubbers was demonstrated during functional testing at either the completion of their fabrication or at a subsequent date.

i l

l 3/4.7.9 SEALED SOURCE CONTAMINATION The limitations on removable contamination for sources requiring leak testing, including alpha emitters, is based on 10 CFR 70.39(c)

I limits for plutonium. This limitation will ensure that leakage from byproduct, source, and special nuclear material sources will not exceed allowable intake values.

3/4.7.10 FIRE SUPPRESSION SYSTEMS DELETED 1

l l

l l

ARKANSAS - UNIT 2 B 3/4 7-6 Amendment No. 44G l.

I l

l l

l l

l Mark-up of ANO-2 Technical Specification Bases l

(For INFO Only) 1 l

l l

L 1

f I

i r

PLANT SYSTEMS BASES i

dro provide further assurance of snubber reliability, a represente-tive sample of the installed snubbers will be functionally tested dueing pl:nt :h:td:rn: at 18 month intervals.

("Once each refuelina shutdown" as indicated in the specification defines the freauency, not the operational mode required for performance of functional testina of snubbers.)

AlternativeLv. snubbers may be tested on-line.

These tests will include stroking of the snubbers to verify proper piston movement, lock-up and bleed.

Observed failures of these sample snubbers will require functional testing of additional units. To minimize personnel exposures, snubbers installed in areas which have high radiation fields during shutdown or in especially difficult to remove locations may be exempted from these functional testing requirements provided the OPERABILITY of these snubbers was demonstrated during functional testing at either the completion of j

their fabrication or at a subsequent date.

3/4.7.9 SEA 1ED SOURCE CONTAMINATION The limitations on removable contamination for sources requiring leak testing, including alpha emitters, is based on 10 CFR 70.39(c) linits for plutonium. This limitation will ensure that leakage from byproduct, source, and special nuclear waterial sources will not exceed j

allowable intake values.

3/4.7.10 FIRE SUPPRESSION SYSTEMS DELETED l

ARKANSAS - UNIT 2 B 3/4 7-6 Amendment No. 4-34

.