E000-96-011, Forwards Core Spray Sparger Insp Rept TR-110 for Cycle 16 Refueling Outage Which Describes non-destructive Exams That Had Been Performed on Core Spray Spargers
| ML20134C881 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 10/07/1996 |
| From: | Keaten R GENERAL PUBLIC UTILITIES CORP. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20134C884 | List: |
| References | |
| 6730-96-2309, E-96-11, E000-96-011, NUDOCS 9610090344 | |
| Download: ML20134C881 (1) | |
Text
.
i I
{
GPU Nuclear, Inc.
(
U.S. Route #9 South NUCLEAR P*'t O"'c' Bc* 3**
Forked over, NJ 08731-0388 Tel 609-971-4000 October 7, 1996 E000-96-011 6730-96-2309 l
U. S. Nuclear Regulatory Commission i
Attention: Document Control Desk i
Washington, DC 20555 l
)
Gentlemen:
Subject:
Oyster Creek Nuclear Generating Station (OCNGS) l Dxket No. 50-219 Facility Operating License No. DPR-16 Core Spray Sparger - 16R Outage Inspections The Oyster Creek Nuclear Generating Station Technical Specifications, Appendix A, para. 6.9.3.d, and the Facility Operating License, para. 2.C.(5), require that a special report presenting the results of the in-service inspection of the core spray spargers during each refueliny outage be provided for review and that authorization be obtained from the Commission's staff before the plant is restarted from each refueling outage.
Topical Report No. TR-110, which is enclosed for youi teview, is the core spray sparger -
inspection report for the Cycle if refueling outage. It oescribes the non-destructive examinations that were performed on the core spray spargers and the associated in-vessel annulus piping. The sparger assemblies and in-vessel annulus piping were inspected utilizing a remote visual camera examination supplemented with an optional air test. The report documents that no new relevant indications or anomalies were found and no change in pre-existing conditions were noted since the prior Cycle 15 refueling outage inspection.
If you have any questions or comments on this submittal, please contact Mr. Michael Laggart, Manager, Corporate Nuclear Licensing at (201) 316-7968.
Very truly yours, r
I R.M hr 9610090344 961007 W. Keaten
$DR ADOCK0500g9 Vice President and irector Engineering
}
RWK/DPK/jr Enclosure cc:
Administrator, Region 1 W
f-g Senior Resident Inspector i
090024 Oyster Creek NRC Project Manager i
-.