L{ellna August 2,1985 Florida Power Corporation ATTN: Mr. W. S. Wilgus Vice President Nuclear Operations P. O. Box 14042, M.A.C.H-2 St. Petersburg, FL 33733 Gentlemen:

SUBJECT:

CRYSTAL RIVER REQUALIFICATION EXAMINATION REPORT 302/0L-85-03 The NRC administered requalification examinations on July 9-11, 1985, to employees of your company who are licensed to operate the Crystal River Nuclear Plant. At the conclusion of the examinations, the examination questions and oreliminary findings were discussed with those members of your staff iNtified in Examination Report, Enclosure 1.

A table summarizing the examination results for each examined individual is provided as Enclosure 2.

Copies of the written examination questions and answer key are included in this report as Enclosure 3.

A requalification program evaluation report covering these examinations and the previous May 1985 requalification examinations is included as Enclosure 4.

Based on the overall pass rate of 71%, we continue to regard your Requalification Program as deficient.

In accordance with'10 CFR 2.790(a), a copy of this letter and Enclosures 1, 3, and 4 will be placed in NRC's Public Document Room. is exempt from public disclosure pursuant to 10 CFR 2.790(a) and will not be sent to the Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely, (Original signed by VLBrownlee)

Virgil L. Brownlee ReactorProjectsBranch2 DivisionofReactorProjects

Enclosures:

1.

Examination Report 50-302/85-03 2.

Table of Examination Results (Official Use Only-Privacy Act Information 3.

R0/SRO Exam Questions and Answer 4.

Requalification Program Evaluation Report i t v

3~ M A

~. - _ _ _ _... - _ _

u Florida Power Corporation 2

August 2,1985 i

J cc w/encls. 1, 2 & 4:

)

E. M. Howard, Director, Site Nuclear i

Operations P. F. McKee, Plant Manager cc w/encls. 1, 2, 3, & 4:

L. C. Kelley, Manager, Nuclear Operations

)

Training i

bec w/encls. 1, 2, 3 & 4:

l Senior. Resident Inspector bec w/encls. 1 & 4:

1 Project Manager, NRR i

State of Florida 1

)

'bec w/encls. 1, 3 & 4:

{

Operator Licensing Branch, DHFS, NRR Document Control Desk bec w/o encis:

K. Clark, RII i

i 1

i i

i l

t i

i I

RII RI RI RII RII1 i

'LLee:es LLd er AWilson Cku'lan

/nciera 3/85 hf/7,/85 07/29/85 07/} /85 07j[b/85 07/

/