Withdraws 850830,0918 & 1016 Requests for Amend to Tech Specs Re Specific Alternatives to Tube Plugging in Steam Generators.Results from eddy-current Testing Performed During Present Refueling Outage Indicate Rev Unnecessary
ML20133N688
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 10/25/1985
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8510300008
Download: ML20133N688 (1)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _

SOUTH CAROLINA ELECTRIC & GAS COMPANY Post OFF6CE 764 cowus.A. sourw caacu~a 292 s Oc tob er 25, 1985 o w omo.;-

V'CE PmES CE meY NGCLEan optaario=5 Mr. Harold R. Denton, Director Of fice of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Withdrawal o f Amndcunt Request

Dear Mr. Denton:

By letters f rom Mr. O. W. D ixon, J r. to Mr. H. R. Denton dated August 30, 1985, Se p tembe r 18, 1985, and October 16, 1985, South Carolina Electric and Gas Company (SCE&G) requested a revision to the Virgil C. Summer Nuclear Station Technical Specifications to allow for specific alternatives to tube plugging in the steam generators. Based on the results of eddy-current testing performed during the present re fueling outage, SCE&G has determined that the amendnunt is not necessary and requests that the Technical Specification revision be wit hd rawn.

If you should have any questions, please advise.

Very truly yours,

/ I.ft N'

O. W. Di on AMM:0WD:tdh c:

V. C. Summer T. C. Nichols, Jr./0. W. Dixon, Jr.

E. H. Crews, Jr.

E. C. Roberts W. A. Williams, Jr.

H. R. Denton G. N. Grace Group Managers D. A. Nauman O. S. Bradham C. A. Price C. L. Ligon (NSRC)

K. E. Nodland R. A. S t ou gh G. O. Pereiva1 0

NRC Resident Inspector I

1g J. B. Knotts, Jr.

H. G. Shealy NPCF 8510300008 851025 File PDR ADOCK 05000395 PDR p