- T AE4L E II U S NUCLEAR REGULATORY COMMISSION OFFICE OF INEPECTION AND ENFORCEMENT CONFIRMATORY MEASUREMENTS PROGRAM FACILITY:
D.C. COOK FOR THE 4 OUARTER OF 1984
_ _ _. - - - N R C - - - - - --
LICENSEE----
---LICENSEE:NRC----
SAMPLE ISOTOPE RESULT ERROR RESULT ERROR RATIO RES T
L WASTE EdETA 5.SE-06 2.OE-07 1.3E-05 3.7E-06 2.3E 00 2.9E 03 D
H-3 5.SE-02 6.OE-04 5.SE-02 1.1E-04 1.OE 00 6.SE 01 A
SR-89 1.4E-08 C.OE-09 1.4E-08 4.6E-09 9.OE-01 1.SE 00 N
SR-90 2.OE-09 5.OE-09 < 5. 6E-09 O.OE-01 2.SE 00 4.OE-01 N
T TEST RESULTS:
A= AGREEMENT D= DISAGREEMENT