ML20133M098

From kanterella
Jump to navigation Jump to search
Requests Approval for Shipment of Single Layer Load of Fuel Elements by Any Carrier Methods for License SNM-33
ML20133M098
Person / Time
Site: 07000036
Issue date: 02/09/1959
From: Leaders W
MALLINCKRODT, INC.
To: Johnson L
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20133G976 List: ... further results
References
FOIA-96-343 NUDOCS 9701220259
Download: ML20133M098 (4)


Text

. -

.. a. ~,

vm

'~

MALLINCKRODT CHEMICAL WORKS

~

i 4

um v r.c t u ne ns o r FINE CHEMICALS rOR MEDICIN AL, PHOTOGRAPHIC

^B[AOonE,st t e s* ea d>o ca<ca-1 ANALYTICAL AND INDUSTRIAL PURPOSES

.. ?f,U/. -

,,,,,g;;;;;pf,.,,,

[e M".' "3," d'.il%&~.:::::,1"R2*is::::r.'M";.'??!

,. =,s s - s a.u.c," oce...<

[>#f!.Y

. 7. M O.

= ". W,. S T. L b!'Y l

/ /g c f,/

9 Fcbruary 1959 i

,(~.-

4-Sl /

4e T

Q l

g AIR HA l./.

4 i

/

w g) 7' Mr. IJall Johnson

@N [h [

J g.

7 i

Licensing Ilranch G

Div. of Licensing & Regulation U. S. Atomic Energy Coenission

  1. '/g f g g \\g Washington 25, D.C.

Special fluelcar Materini License S%33 - Shipping Containers for j

SUNECT:

Fuel Elements Dear Mr. Johnsons W114nokrodt Nuclear Corporation is preparing to nanufacture for Allis-Chalmers several thousand fuel pins containing U0, pelleta of nearly theoretical density, l

Each pin will contain These pins are approximately 18" long and 7/16" diameter.we Iaopose to packa i

255 srams of 00s at 1.8% enr4ah===t.

tidt drum which has been thorocably tested by the military services of the 1he pins will be suh ed in this drum by polystyrens foam dun-t kited States.

Eneh drtsa will, therefore, contain mage.

255 x.sats x 170 = 32,216 grams u 32,216 x. 018 = 687.89 grams gese Limited ante quantity of 1.8% assay uranium is 135 kg l

NOTE:

U per table XVII, 51039 Part L Deleted, l

me anah==4mm1 details at the paskass are shoum on Drawing No. 33694 idnish is 31 drina helding the feel tubes has the Military designatien S e cent:

Wl atteobed.

and is equipped with a heavy bolt ring. elosure to make it water iiskt.

AE8025-20 zw to enter dra will be a standard 55 angen drum et osuusses. V "M--"ys; this h, !

M

%. i q

bM

W

,g6milw~4e.ee thd4 he' tees 311em sW:

m J

a d $6 $s a tteig @ ed e st-

  • W 4pete 4 ' h:

.te age tis eWhedeer edW3W N

?, ljd ute $antaan open'yS31heedyqit usei Y

i i

6

.hh.h,en, h

l....

ik N[h..

I he calculatteine below are a ocupariiseeref'th's eetid angle iby. is '

array with the solid angle subtended by the 1

dran in a close packed he-= &

." birdoggs used by the Atcada Ehargy Ca==f amico and its ocatractors s,,,

(.

PDR FOIA

~

f FLOYD96-343 pop

~

. v.

,.a.

h a ~~ ~

L

^

0 F C h".T. b' " 1. *.:.'

.i;. :..: ;. o.

'u

'n:ia particuler birdergo is 20 :n the ed;a or.tcriar.nd the centor pot has in*c-nal dinonsiena of 9-0/h' di,. cter en-i j' dsop.,

n.o pot la cantored in the etco.,

TID-7016)glo e st:n::c/ 'oy Ire;cacd ~ nip; ins 'hn0r.1 x.

Using F.ot. hod 3-1, Page lh ol' Solid.'n 1

H = 18.75" D = 10.5" L = 18.5" 0

arctan / g.25)2 + (p 25p

.567h7 18.75 0 - 29 3h*

ain 0 - 0.h9 %

A= & sin 0=

x 0.h9%

kA-64-3.3159 storadians 3.3159

  • 26.388% of hststeradians.

For the 20" birdcage of the Ocamission and its contractors, using the same method, we naast consider a nh cage array in a single layer square.

./2,g is for adjacent containers A a is far the carner containers.

For./). 2 0

arctan /(h.875)a + (2.5)*. o.3623 15.125 l

'O - 19*55' sin o = o.%o65 75 4 2 - y sin 0 8 * [ h x. 1 065 l

i

,U g 3. o,h391 l

e, j,,,

}.

@g g, v,-

- Q..

. j Ttt Q$1%y.b ';ff&

'* ~

e;~.y{.f~hgQ:;ml&,,m:knen 2

=

==

~

v. ' w: hv.

4.: ~ r.

yD,..Jpf Jifg,.

.,~

/

,y..

.r. iya.t;.:&na.=

?cy.,cco iur: rj 1?%

.:..u. u..=.:

w.i;pi:a an a..=.

7er./L a f(b.6f5) G Q,5)2 0.2239 c = cretan g3 y a

Oa " 13*10' i

sin Oa = 0.22778 A a = 2__x 9 75-x 0.22778 = 0.1896 23.h25 I

A= h A2 + h el = 2.51h8 storadians a

2.51h8 - 20.5% h(

Bose cniculations are nado for a singlo layer array; however, NOTE:

tho drawing of this birdcago distinctly shows stacking lugs on It must, therefore, be assumed that the top side of the cago.

these birdcages are in fact stacked when used by AEC contractors J

Se solid angle calculated for shipments of large quantities.

abow would be very conservative under these circumstances.

De following table compares the proposed shipping centahr with the standard 20" AEC birdcage on a series of points:

Proposed Shipping Container AEC 20" Birdcage Double drum, both gasketed Water tightness One gasket 0.688 kg 11.5 kg Ussa h7.16 kg Unas Carload quantities 1000 kg Ussa Edge to edge 10.5" 13.5*

spacing Solid angle 20.5% of k #

26.h% of k rr" subtended Do pellets in sealed aluminum Material to be Solid uranium metal or com-s tubes shipped pounds - any enrichment s

- _. upwggy,.e g,. _, *

i. Q q...

y,:q.j.j,(.lljg'g 4

- 4 TMy $,u

,.~gg:~wr.~f-w:yyy w a.

e

v.,. c

}

n.

um.

'N tn.,,

x' 1

t l-

?f

_.t. - -

'~

~

' ' a.

i-v.

.3....,

..a

,w

.s,.....,,._,.,y

- ~,

y ihipp b / ';

.u

' r. ;e '. : 1_;c.1 i'ased en the fact that tha ;ropccad f.ipping contaircer off:rJ n considora'cly gester r:ar2in of ::af0C then the 2C ' /C0 birdec o from the ste.ndpoint of (1) quantity to be chippod, (2) adge to cdge.apaci c, (3) prot:: tion fron dcrays, and (h) unter in 19 dr.p, :o rognot a;;rcyc1 fer di=cnt of c.lngle layer loads by any cor.on cc:-rior mothed.

Very truly yours, F

RICKRCDT h Ut CORPORATIC?i Yb -

W. M. Londor Technical Eirector

'a & dj 8

4 4

f l$*

+

if'e

'.};,'

N, s

{' \\

'h) 4 2

Wl

  • t.

y e

%m<_l' 14. i,n -

!i t. :..

- tr,... ^ r wgg

4g -g.qqpw.y g,#

w p, - 3 4.f' p :- 4,g g e a g 4 g ; g,g.,.

v.u

, 7.~

b 2

.cr

.,.M..

(

s v,

.w -

? '}t 'f'MII,$ g3[,t ?$'I.,'] \\

[?sh A n

7 s

s 7

.r-

.p

'[Ql*

' $);'e# F,l t V N, *,*

h$ #

h Yes') AhN$tn',Y T '!

.#_ ; < T ' s n..s5*

v ;

s*

'r^

.. \\ %N s,;

'y

,(

s s ;)' ~ + 1 E h.

hk' lbib hk

.db )'Ayj b SA b*'dkMN' "1 N, N

@ 4' NQ h) h A

,