a NUMOHAWK Y NIAGARA NINE MILE POINT-UNIT 2 P.O. BOX 63, LYCOMING, NY 13093/ TELEPHONE (315) 343-2110 September 27, 1985 (NMP2L 0504)

Mr. R. W. Starostecki, Director U.S. Nuclear Regulatory Comission Region I Division of Reactor Projects 631 Park Avenue King of Prussia, PA 19406 Re: Nine Mile Point - Unit 2 Docket No. 50-410

Dear Mr. Starostecki:

Enclosed is a final report in accordance with 10CFR50.55(e) for the problem concerning issuance of trim design details by ITT Grinnell without approved design drawings. This problem was reported via tel-con to J. Linville of your office on March 6,1985.

Very truly yours, C. V. Mangan Senior Vice President CVM/GG/dmb (1237H) xc: Director of Inspection and Enforcement U.S. Nuclear Regulatory Comission i

Washington, DC 20555 R. A. Gram, NRC Senior Resident Inspector 8510180125 850927

~

PDR ADOCK 05000410 3

S PM g

I g

F 4

g

a NIAGARA M0 HAWK POWER CORPORATION NINE MILE POINT - UNIT 2 DOCKET N0. 50-410 Final Report for a Problem Concerning Trim Design Details (55(e)-85-09)

Description of the Problem During a review of a planner package by ITT Grinnell Quality Assurance and the Authorized Nuclear Inspector, it was discovered that ITT Grinnell Engineering had issued trim design details to Construction without approved design drawings.

ITT Grinnell used a standard detail from Specification No.

NMP2-P30lC which did not apply.

Specific details on approved drawings were required by Specification No. NMP2-P301C.

Analysis of Safety Implications ITT Grinnell Quality Assurance issued Corrective Action Report No. 666 to document the investigation of this problem.

ITT Grinnell recalled all of its planner packages and reviewed them to identify those cases where this problem occurred.

This review resulted in the issuance of 21 Nonconformance and Disposition Reports related to the use of ITT Grinnell's trim design details.

Only 12 Nonconformance and Disposition Reports involved Category I equipment.

Since it was deterciined that the nonconformances did not jeopardize system or component integrity, all of the 12 Nonconformance and Disposition Reports were dispositioned " accept-as-is".

Therefore, if this condition were to have remained uncorrected, it could not have adversely affected the safety of operations of the plant.

Corrective Action None required.