Portable area monitors capable of detecting gamma radiation in the range of 0.10 to 50 mRems/hr may temporarily replace fixed area monitors described above' provided that the required alarms are operational.
Portable Monitors:
During reactor operation, operable portable survey instruments shall be readily available to the reactor operator for measur-ing beta-gama exposure rates with ranges designated 1.0 mR/hr or less to over 50 R/hr, and fast plus thermal neutron dose rates from 0.04 to 1,000 mrems/hr.
One or more portable survey instruments for measuring beta-gama exposure rates with a minimum range of 10 mR/hr to 50 R/hr will be kept available to the reactor staff in an external location (normally the security office) to facilitate obtaining radiation readings if a reactor radiation alarm should be activated.
l l
l i
l l
l Worcester Tech Specs 7
l 7/25/84 l
t 8508090100 840726 PDR ADOCK 05000134 l
P PDR t
- -