ML20133D796

From kanterella
Jump to navigation Jump to search

Responds to Re NUREG-0737,Item II.E.1.1 Concerning Auxiliary Feedwater Sys Tech Specs & Request to Review SER & Submit Revised Amend Application.Revised Application Will Be Submitted by 850830
ML20133D796
Person / Time
Site: Davis Besse 
Issue date: 08/01/1985
From: Williams J
TOLEDO EDISON CO.
To: Stolz J
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.E.1.1, TASK-TM 1175, TAC-55782, NUDOCS 8508070463
Download: ML20133D796 (1)


Text

TOLEDO

%ms EDISON Docket No. 50-346 JOE WILUAMS. JR.

Senor Vce Presdent-Nudear License No. NPF-3 lll8l'j8 ","j Serial No. 1175 August 1, 1985 Director of Nuclear Reactor Regulation Attention:

Mr. John F. Stolz Operating Reactor Branch No. 4 Division of Licensing United States Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Stolz:

This is in response to your letter dated May 9, 1985 (Log No. 1742) concerning Auxiliary Feedwater System - Tcchnical Specifications related to NUREG-0737, Item II.E.1.1.

Toledo Edison was requested to review the enclosed SER and submit a revised license application. There has been communication between the NRC Staff and Toledo Edison on this subject.

Therefore, the revised amendment application will be submitted by August 30, 1985 for the Davis-Besse Nuclear Power Station Unit No.

1.

Very truly yours, ElkE

GAB:lah cc: DB-1 NRC Resident Inspector 0{

8508070463 050001 DR ADOCK 05 36 THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MAOISON AVENUE TOLEDO. OHIO 43652 L

.