CONFIRMATORY SURVEY PLAN FOR SURVEY UNITS 1 AND 2 i
INTERIOR OF BUILDING 2 ENGELilARD PLANT PLAINVILLE, M ASSACilUSETTS J
l 4
l INTRODUCTION AND SITE IIISTORY D E. Makepeace, predecessor of the current Engelhard Corporation, manufactured nuclear fuel elements at its plant on Route 152 in Plainville, Massachusetts from 1957 until cessation of operations in 1962. Manufacturing operations were performed under the Atomic Energy Commission (AEC),
predecessor agency to U.S. Nuclear Regulatory Commission (NRC), Docket No. 070-139. The Building 2 interior and equipment used in the fuel fabrication operations were decontaminated and a final radiological survey was performed by Engelhard Corporation in 1963. Based on the results of this survey, and the AEC's confirmatory survey of the Building 2 interior and equipment, the facility licenses were terminated (Engelhard 1996). The decontaminated equipment was removed from the plant and sold to the Italian government. Subsequently, the area used for nuclear fabrication was converted to other non-nuclear metal fabrication operations _
A radiological scoping survey was conducted of the plant in July 1988 as a part of a multi-phase site assessment initiated by Engelhard Corporation to identify potential areas of environmental concern.
This survey identified residual contamination consisting of U-238, U-235, and U-234, with low enrichments of U-235.
A more detailed characterization survey of Buildings I and 2 was conducted in March 1994, which resulted in delineating afTected and unafrected areas based on current NRC regulatory guidelines.
9701100054 961230 PDR ADOCK 070001,39 C
PDR Prepared by the Environmental Survey and Site Assessment Program, Environmental and Health Sciences Division, Oak Ridge Institute for Science and Education, under interagency agreement (NRC FIN No. A-9093) between the U.S. Nuclear Regulatory Commission and the U.S. Department ofEnergy.
Engelhard Plant. Plamville. MA (6710 - December 30 1996 h '<wir pimengelhard 001
An NRC-approved Decontamination Plan for releasing the Building 2 afTected areas in accordance with current criteria was then implemented These areas were decontaminated from June through I
October 1996 (Engelhard 1996).
The building decommissioning activities consisted of removing remaining equipment from the affected area, collecting and removing loose material, scabbling contaminated surfaces (mainly floors and some walls) and collecting the removed material, and sawing and breaking concrete floors to remove piping and floor joints. The piping was generally found to be physically intact and without perforation, with a few small pockets of contaminated soil under locations where the pipe had been cut-contaminated soil was removed. In addition, expansion joints were cut out of the floor to remove any contamination that had collected in these locations and localized areas of contaminated material were removed from overhead piping, structural members. and electrical buss ducts.
Remediation control surveys performed by Engelhard showed that all surfitees were within NRC residual surface contamination criteria.
Engelhard conducted a final radiological status survey of each of the two survey units in Building 2 as the decontamination efrort was completed. The results of the survey demonstrated that the radiation levels in the building satisfied NRC residual contamination guidelines, established for release offomierly licensed sites to unrestricted use. The final status survey report covers only Buildings 1 and 2; the decommissioning project for the exterior regions of the facility is scheduled to be undertaken later upon NRC approval of Engelhard Corporation's proposed approach to exterior decontamination.
The U.S. Nuclear Regulatory Commission, Division of Waste Management, has requested that the Environmental Survey and Site Assessment Program (ESSAP) of Oak Ridge Institute for Science and Education (ORISE) perform a confinnatory survey of Building 2 at the Engelhard Corporation plant in Plainville, Massachusetts.
{
2 h iewapplann engelhard WH Erigelhard Phnt. Plamville, MA (67N). December M. IW6
SITE DESCRIPTION The Engelhard facility is located at 30 Taunton Street (also known as Massachusetts Highway Route 152)in Plainville, Norfolk County, Massachusetts. The facility housed areas both used for nuclear fuel fabrication and non-nuclear operations-fuel element fabrication operations were totally segregated from the non-nuclear manufacturing and other operations.
Buildings 1 and 2 were the only buildings existing at the time of nuclear fuel fabrication. Neither Building 1 or 2 is currently being used for any Engelhard operations, and there is no Engelhard worker population in these buildings. The afTected areas in Building 2 were well delineated, based on the results of the characterization survey and knowledge of the plant operating history. The afTected areas were entirely within Building 2 and consisted of:
Rooms where localized average surface contamination levels on the floor and in a
cracks and crevices exceeded applicable residual surface contamination criteria.
These rooms included the tunnel ramp, the former precious metal storage room (2L),
the former scrap melt room (2M), the corridor and part of the floor in the room north of the scrap melt room (2N), part of the floor in the former melt room (2H), and the room on the left of the entrance corridor in Building 2 (2B).
Rooms where localized average floor surface contamination levels were less than the residual surface contamination release criteria, but were elevated above background levels (greater than 2 to 3 times background). These rooms were decontaminated based on ALARA considerations. The rooms were designated as 2A,2C,2D,2F, room to the north of 21 (subsequently designated 2P), and 2K Subtloor piping originating in the affected area where elevated radiation levels were
+
l measured in the drain inlet openings and outlets.
l l
The remainder of Building 2, and all of Building 1, was classified as unalrected.
During decontamination activities, rooms 2E and 2G were added to the afTected area.
Engelhard Plant, Plamville. MM67N; December M IW,,
3 3 esur piens enseisora ooi
1 l
OBJECTIVE The objective of the survey is to obtain sutlicient radiological data for use by the NRC in evaluating l
l the radiological condition, relative to current guidelines, ofinterior areas of Building 2 of the l
Engelhard facility.
RESPONSIBILITY Work described in this survey plan will be performed under the direction of William L (Jack) Beck, Program Director, and Eric W. Abelquist, Assistant Program Director of ESSAP. The cognizant site supervisor has the authority to make appropriate changes to the survey procedures as deemed necessary. After consultation with the NRC site representative, the scope of the survey may be altered based on findings as the survey progresses.
i DOCUMENT REVIEW
]
ESSAP has reviewed Engelhard's final survey report for Survey Units I and 2 in Building 2 (Engelhard 1996) and correspondence between the NRC and Engelhard concerning NRC's comments j
on the final report. The information was used i'n the development of this survey plan.
SURVEY PROCEDURES i
A survey team from ESSAP will visit the Engelhard facility and perform a visual inspection and independent measurements and sampling. ESSAP survey activities will be conducted in accordance l
with the ORISE/ESSAP Suney Procedures and Quality Assurance Manuals (ORISE 1995a and b).
Specific survey procedures applicable to this survey are listed on pages 8 and 9 of this survey plan.
t Deviations to the survey plan or procedures will be documented in the site logbook. The survey will consist of a review of the final status survey data; alpha, beta, and gamma scans; surface activity measurements; exposure rate measurements; soil sampling; and, miscellaneous sampling.
En6elhard Plant, Phunville. MA (678). December 30.19%
4 h w3aap plans engelhard 001 l
i e
Engelhard divided the Building 2 interior areas into two affected survey units. Survey Unit 1 includes 2L,2M, and the tunnel Survey Unit 2 includes 2A, entry, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2K, 2N, and 2P.
l REFERENCE GRID Measurement and sampling locations will be referenced to either Engelhard's grid ystem where possible or to prominent building features and recorded on appropriate field drawings.
SURFACE SCANS Surface scans for alpha, beta, and gamma radiation will be performed on 50 to 100% of the afTected areas, and 10 to 25% of the unafTected areas in Building 2. Scans will be performed using gas proportional, GM, and/or Nal scintillation detectors coupled to ratemeters or ratemeter-scalers with audible indicators. Locations of elevated direct radiation identified by surface scans will be marked for further investigation i
I SURFACE ACTIVITY MEASUREMENTS Construction material specific backgrounds will be determined in areas of similar construction but without a history of radioactive material use.
Surface activity measurements for determining total residual uranium surface activity levels will be performed at a minimum of10 locations in each room in Building 2. Surface activity measurements will also be performed on the building roof Additional measurements will be performed at locations of elevated direct radiation detected by surface scans. Direct measurements will be performed using gas proportional detectors coupled to ratemeter-scalers. A smear sample for determining removable gross alpha and gross beta activity will be collected at each direct measurement location.
Engelhard Plant. Plmnville. MA (678)- December M i c,;o 5
n eoer pi,1, en,cin.,a oni
Areas of residual activity, in excess of the guidelines, will be brought to the immediate attention of Engelhard and the NRC. If additional remediation is performed during the ESSAP survey, follow-up measurements will be performed.
EXPOSURE RATE MEASUREMENTS Background exposure rate measurements will be performed at five to ten locations of similar construction, but without a history of radioactive material use. Exposure rates also will be measured at a minimum of five locations within both survey units in Building 2.
Exposure rates will be measured at I meter above the surface using a microrem meter.
SOIL SAMPLING Background soil concentrations determined from a previous ESSAP survey site in the vicinity will be used as background soil concentration data for this site (ORISE 1985).
. Soil samples will be collected from trenches and subfloor areas at a minimum of 10 locations within the Building 2 areas. Additional soil samples will also be collected from any locations of elevated direct radiation identified by surface scans.
MISCELLANEOUS SAMPLING Samples of miscellaneous material such as paint, drain residues, and roof sediments may be collected from locations where material may have accumulated, or from locations of elevated direct radiation detected by surface scans.
SAMPLE ANALYSIS ANG uATA INTERPRETATION Samples and data will be returned to ORISE's ESSAP laboratory in Oak Ridge, Tennessee for analysis and interpretation. Sample analyses will be performed in accordance with the ORISE/ESS AP Laboratory Procedures Manual (ORISE 1995c). Soil samples will be initially analyzed by solid-state b
Engelhard Plant Plamulle. ALU673) Daember 30. Im h hypl.mmplhard wt
i l
l l
?
l gamma spectrometry. The radionuclides ofinterest are U-235 and U-238; however, spectra will be reviewed for other identifiable photopeaks. A limited number of samples may also be analyzed by alpha spectrometry to determine isotapic uranium abundances. Soil and sediment sample results will be reported in units of picocuries per gram (pCi/g). Smears will be analyzed for gross alpha and gross beta activity using a low-background proportional counter. Direct measurement data and smear data 2
will be converted to units of disintegrations per minute per 100 square centimeters (dpm/100 cm ).
Specifically, the residual uranium surface activity will be calculated by:
1 I
surface activity = 2.9 *
(efficiency) (probe area /\\00) l This equation is specific to measurements of 4% enriched uranium using gas proportional detectors 2
(3.8 mg/cm window) calibrated to SrY-90; the technical basis is documented in the site logbook.
Exposure rates will be reported in microroentgens per hour (pR/h). The data generated will be compared with the NRC guidelines established for release for unrestricted use. Results will be presented in a draft report and provided to the NRC for review and comment.
GUIDELINES The primary contaminant of concern for this site is uranium. The applicable NRC guidelines for residual uranium surface activity levels are (NRC 1987):
Uranium 2
2 5,000 dpm a/100 cm, total, averaged over a 1 m area 2
2 15,000 dpm a/100 cm, total, maximum in a 100 cm area 2
1,000 dpm a/100 cm, removable activity The exposure rate guideline is 5 R/h above background at one meter above building surfaces (NRC 1991) l 7
h 4 ssip p.sns i ngdt.ird (n 4 EngelharJ Plant, Pl.imvills. Alai 674 Iktember M lWi
?
)
i The generic NRC guidelines for residual concentrations of uranium in soil are provided in the NRC
-l Branch Technical Position on " Disposal or Onsite Storage of Thorium and Uranium Wastes from Past Operations" (NRC 1981). Specifically, the Option I average soil guideline for enriched uranium is 30 pCi/g.
TENTATIVE SCllEDULE Measurement and Sampling January 8 and 9,1997 Sample Analysis January 1997 Draft Letter Report January 24,1997
)
LIST OF CURRENT PROCEDURES i
Applicable procedures from the ORISE ESSAP Survey Procedures Manual (Revision 9; April 30,1995) include:
I Section 5.0 -Instrument Calibration and Operational Check-Out
]
5.1 - General Information 5.2 Electronic Calibration of Ratemeters 5.3 Gamma Scintillation Detector Check-Out and Cross-Calibration 5.5 GM Detector Calibration and Check-Out 5.6 Proportional Detector Calibration and Check-Out 5.8 Pressurized Ionization Chamber Calibration and Check-Out 5.10 Floor Monitor Check-Out 5.13 Field Measuring Tape Calibration Section 6.0 Site Preparation i
6.2 Reference Grid System l
4 S
h 'essar planswgelhard in11 Engelhard Plant Pla nulle. Mw78 e thember V1.1%
Section 70 Scanning and Measurement Techniques 7.1 Surface Scanning 7.3 Alpha Radiation Measurement 7.4 Beta Radiation Measurement 7.5 Gamma Radiation (Exposure Rate) Measurement Section 8.0 Sampling Precedure 8.1 Surface Soil Sampling 8.2 Subsurface Soil Sampling 8.7 Determination of Removable Activity 8.8 Miscellaneous Sampling 8.9 Sample Identification and Labeling Section 9.0 Integrated Survey Procedures 9.2 General Survey Approaches and Strategies Section 10.0 Health and Safety and Control of Cross Contamination Section 11.0 Quality Assurance and Quality Control Applicable procedures from the ORISE/ESS AP Quality Assurance Manual (Revision 7; January 31, 1995) include:
Section 5 Training and Certification Section 6 Equipment and Instrumentation Section 7 Quality Control Section 8 Sample Chain-of-Custody Section 9 Data Management Section 10 Data Review and Validation Section 11 Records llandling and Storage h
h mp plans engelhad ml Engelh.rd Plant, Pl.unville. AtA (678). Iwember W IPk..
,e l
=
REFERENCES 1
Engelhard Corporation. Final Status Survey Report, Survey Units 1 and 2 in Interior of Plainville, Massachusetts Plant of Engelhard Corporation. Plainville, Massachusetts; November 1996.
Oak Ridge Institute for Science and Education (ORISE)
Radiological Survey of the Texas Instruments Site, Attleboro, Massachusetts. Oak Ridge, Tennessee; January 1985.
Oak Ridge Institute for Science and Education.
Survey Procedures Manual for the Energy / Environment Systems Division, Environmental Survey and Site Assessment Program, Revision 9. Oak Ridge, Tennessee; April 30,1995a.
Oak Ridge Institute for Science and Education.
Quality Assurance Manual for the Energy / Environment Systems Division, Environmental Survey and Site Assessment Program, Revision 9. Oak Ridge, Tennessee; January 31,1995b.
Oak Ridge Institute for Science and Education.
Laboratory Procedures Manual for the Energy / Environment Systems Division, Environmental Survey and Site Assessment Program, Revision 9. Oak Ridge, Tennessee; January 31,1995c.
U.S. Nuclear Regulatory Commission (NRC). Disposal or Onsite Storage of Thorium and Uranium Wastes from Past Operations. Washington, DC: Federal Register 46 (205): 52061-52063; October 23,1981.
U.S. Nuclear Regulatory Commission. Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of License for Byproduct, Source, or Special Nuclear Material Washington, DC; August 1987.
U.S. Nuclear Regulatory Commission. OfUce of Nuclear Safety and Safeguards, Review Plan:
Evaluating Decommissioning Plans for Licensees Under 10 CFR Parts 30,40, and 70, Washington, DC; 1991.
10 n
,n smngum,a mi Engelhard Plant Plainville. MA i 67N) - Ikcember L1 19.,
r ATfACllMENT A PERFORMANCE PERIOD FY 97 SPENDING PLAN From To Name of Laboratory:
Dec-96 Mar-97 Oak Ridge Institute for Science and Education RFTA Est. Project Cost Title of Project: #678 97 7
$30,500.00 Engelhard, Plainville, MA Fee or Non Fee Recoverable: Non-Fee NRC Fin Number ORISE Number TAC Number.
A9093 1285.51 A
N COST ELEMENTS Oct 96 Nov 96 Dec 96 Jan-97 Direct Costs
$0.00
$0.00
$6,932.00
$11,553.00 Indirect Costs-(G&A, DOE Factor)
$0.00
$0.00
$2,218.00
$3,697.00 Total Estimate Costs
$0.00
$0.00
$9,150.00
$15,250.00 Project Completion 0.00 %
0.00 %
30.00 %
80.00 %
COST ELEMENTS Feb-97 Mar 97 Apr-97 May 97 Direct Costs
$2,311.00
$2,311.00
$0.00
$0.00 Indirect Costs-(G&A, DOE Factor)
$739.00
$739.00
$0.00
$0.00 Total Estimate Costs
$3,050.00
$3,050.00
$0.00
$0.00 Project Completion 90.00 %
100.00 %
100.00 %
100.00 %
COST ELEMENTS Jun-97 Jul-97 Aug-97 Sep-97 Direct Costs
$0.00
$0.00
$0.00
$0.00 Indirect Costs-(G&A, DOE Factor)
$0.00
$0.00
$0.00
$0.00 Total Estimate Costs
$0.00
$0.00
$0.00
$0.00 Project Completion 100.00 %
100.00 %
100.00 %
100.00 %
ACTMTY INFORMATION Hours Estimated Cost Site Visit 0.0
$0.00 Document Review 10.0
$1,400.00 Presurvey 24.0
$2,500.00 Travel-Labor 54.0
$5,500.00 Travel Other Expenses
$6,200.00 Survey Activities 54.0
$5,500.00 i
Report Preparation 57.0
$6,000.00 Sample Analysis 30.4
$3,400.00 Other 0.0
$0.00 Total 229.4
$30,500.00 12.5.96.678.engelhard.sp,12/5/96-bil 11