CONFIRMATORY ACTION LETTER Docket No. 50-52.

License No. NPF-41 R 2 91985 Arizona Nuclear Power Project P. O.' Box 52034 Phoenix,' Arizona 850,2-2034 Attention: Mr. E. E. Van Brunt, Jr.

Executive Vice President Project Director Centlemen:

Subject:

Post Accident Sampling System (PASS) - Palo Verde Unit 1 This refers to a_tclephone~ conversation held on July 25, 1985 between J. Haynes (ANPP) and J. Crews (RV) and to your letter of July 26, 1985 describing your actions in regard to a post accident containment atmosphere sampling location.

Based upon your letter, it is our understanding that you will not return to Mode 3 until the PASS deficiency is corrected and the PASS is declared operable.

If our understanding concerning your actions in this matter is not correct, you should contact this office promptly. Your cooperation with us in this matter is appreciated.

Sincerely Or;%! ri~. : I Pv -

!:;w 3,turHn J. B. Martin Regional Administrator cc:

J._Bynum bcct J. Axelrad. D/ES OELD G. Knighton, NRR R. Zimmerman (fax)