4 ATTACHMENT Consumers Power Company Palisades Plant Docket 50-255 1984 ANNUAL ENVIRONMENT REPORT ADDENDUM September 19, 1985 hA P

R 9 Pages IC0985-0284-NLO4

Palisades 1986 Environmental Annual Report Addendum A.

Introduction This supplement to the Palisades 1984 Environmental Monitoring Annual Report incorporates a total of twenty-five (25) pieces of analytical data that were unavailable during initial report preparation. The following sampling media types affected by the additional data are: _1) crops, 2) sediment and 3) aquatic biota. There were no significant changes in data interpretation with the incorporation of the completed results.

Sampling media data changes in the Environmental Monitoring Program are detailed in Table RSD-E-03A.

Table RSD-E-03D tabulates the high, low and average annual concentration of isotopes per sampling location. All data changes are noted in the right-hand margin.

B.

Discussion and Interpretation of Results 1.

Sediment Ten (10) previously unavailable sample results (5-Sr89 and 5-Sr90) were incorporated into the 1984 Environmental Monitoring Annual Report. With the additional data, one (1) reporting location was changed. The highest concentration of Sr89 shifted from the South Haven beach location to the plant discharge. All other reporting locations (per specified isotope) remained the same; although there was a slight increase in reporting average for Sr-90.

No reportable levels of Sr-89 or Sr-90 were reached.

2.

Fish Initially, ten (10) previously unavailable analyses (5-Sr89 and 5-Sr90) were to be incorporated into the Palisades supplemental Environmental Annual Report. However, due to some analytical errors and lack of enough remaining sample quantities to complete any reanalyses; only eight (8) sample results (4-Sr89 and 4-Sr90) could be used. There were no changes in highest reporting locations for either Sr89 or Sr90 concentrations. Loss of the two (2) data results did not appear to adversaly affect the Environmental Monitor-ing Program. No reportable limits for Sr-89 or Sr-90 were exceeded.

3.

Crops Again, twelve (12) previously unavailable analyses (2-gross beta, 5-Sr89 and 5-Sr90) were to be incorporated into the supplemental Environmental Annual Report. However, due to some analytical errors and limited sample quantities for the reanalyses; only seven (7) sample results (1-gross beta, 3-Sr89 and 3-Sr90) could be used.

With the additional data, both the Sr-89 and Sr-90 highest reporting locations were changed to location JS (3.5 mi SE of Palisades). The isotopic averages for Sr-89 and Sr-90 also increased. The missing IC0985-0223A-HP01

-: t data appeared to have minimal impact on the Environmental Sampling locations. No Sr-89 or Sr-90 limits were exceeded.

C.

Summary No required Technical Specification analyses were missed in 1984.

Seven (7) analytical results (1 gross beta, 3-Sr89 and 3-Sr90) were missing because of the unavailability of adequate sample quantities (per spec-ified media) for reanalysis. The missing. results did not constitute a significant reduction in the overall Env: ronmental Program. No re' port-ing levels of Sr-89 or Sr-90 were exceeded.

t 6

E IC0985-0223A-HP01

~

Pzgn 1 of 4 l

l TABLE RSD-E-03A Environmental Radiological Monitoring Program Suarnary l

Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1984 to December 31, 1984 Analysis and Lower Limit All All Nonroutine Medium or Total Number of of Indicator Location with Highest Control.

Reported l

Pathway Sampled Analyses Performed Detection (a)

Locations Annual Mean Locations Measurements (c) i Unit of Measurement LLD Mean(b)

Name Mean(b)

Mean(b)

Range (b)

Distance & Direction Range (b)

Range (b)

Air (pci/m )

Gross Beta 627 0.01 (457/468)

CR 55 mi NNE

.03 (152/159)

None 8

j 0.02(.02.03)

(.007.087) 0.02(.02.03)

I-131 627 0.02 all LLD N/A LLD.

None l

l Laka Water Gross Alpha 24 1.0 (0/12)

Discharge 1 ( 1)

(0/12) 1 None (pC1/1) 1 ( 1)

Gross Beta 24 1.0 (12/12)

Discharge 2.4(1.2-3.6) (12/12)

None 2.4(1.2-3.6) 2.3(1.1-3.0)

Tritium 24 100.0 (12/12)

Discharge 490.8 (12/12)

None 490.8(100-1570)

(100-1570) 189.2(100-400)

Drinking Water Gross Beta 12 1.0 l

(pC1/1)

Control, lake and well water samples are drinking water supplies.

l l

Tritium 12 100.0 i

Well Water Cross Eeta 36 1.0 (12/12)

State Park 4.8 (24/24)

None (pCi/1) 1.4(1-1.8)

(1 mi N)

(2.4-9.3) 3.2(0.7-9.3) l M10385-0059A-HP01 r

l

P ge 2 of 4 TABLE RSD-E-03A Environmental Radiological Monitoring Program Summary Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1984 to. December 31, 1984 All.

Nonroutine Analysis and lower Limit All Medium or Total Number of of Indicator location with Highest Control Reported Pathwsy Sampled Analyses Performed Detection (a)

Locations Annual Mean Locations Measurements (c)

Unit of Measurement.

LLD Mean(b)

Name Mean(b)

Mean(b)

I Range (b)

Distance En Direction Range (b)

~ Range (b)

Milk 1-131 48

.5 (0/36)

All LLD N/A' 0/12 LLD None I

(pCi/1)

Sr-89 48 5.0 (0/36)

All LLD N/A 0/12 LLD None i

Sr-90 48 1.0 (36/36)

CH (5 mi SE) 2.8 (12/12)

None 2.8(1-4.5)

(2.1-4.2) 1.5(1-2.6) l Cs-137 48 1.0 (0/36)

All LLD N/A 0/12 LLD None j

j Other Gamma 1.0 (0/36)

N/A N/A 0/12 LLD None i'

Camuna Exposure TLD (monthly) 276 1.0 (234/240)

ST-18 (.75 mi SE) 5.9 (36/36)

None (mR/ month) 5.3(3.3-11.1)

On Perimeter (3.9-11.1) 5.3(3.9-7.2) i l

(mR/ quarter)

TLD (quarterly) 92 (78/80)

ST-04 3.5 mi ESE 19.5 (12/12)

None l

15.4(12.2-27.0)

(16.2-27.0) 15.2(13.2-17.8)

TLD (annually) 23 (19/20)

ST-20 (0.5 mi S) 64.0 (3/3)

None l

(42.0-64.0)

On Perimeter (49.0-55.5)

$2.0 52.6 q

Crops Cross Beta 13 1.0 (12/13)

JS (3.5 mi SE) 2.3 None None l

2.2(0.8-7.0)

Turnip Creens (1.0-7.0)

Sr-89 13 0.025 (2/13)

JS (3.5 mi SE) 0.110 None None 0.080(.025.52) Turnip Creens

(.025.520)

I, M10385-0059A-IIP 01

~

Page 3 of 4 TABLE RSD-E-03A Environmental Radiological Monitoring Program Summary Palisades Nuclear Plant, Docket DPR-20 Van Buren Cour.ty, Michigan, January 1, 1984 to December 31, 1984 Analysis and lower Limit A!!

All Nonroutine Medium or Total Number of of Indicator Location with Highest Control Reported Pathway Sampled Analyses' Performed Detection (a)

Locations Annual Mean Locations Measurements (c)

Unit of Measurement LLD Mean(b)

Name Mean(b)

Mean(b)

Range (b)

Distance & Direction Range (b)

Range (b)

Crops Sr-90 13 0.005 (3/13)

JS (3.5 mi SE) 011 None None 0.010(.005.040) Turnip Creens

(.005-0.040)

Cs-137 13 0.08 (0/13)

N/A None None MDL I-131 13 0.08 (0/13)

N/A None None MDL Other Camma 13 0.1 (0/13)

N/A None None MDL Sedinent Cross Beta 12 1.0 (8/8)

Ludington S Pier 13.3 (4/4)

None 8.2(5.8-10.8)

N/A 10.4(7.5-13.3)

Sr-89 12 0.025 (5/8)

Discharge

.068 (1/4)

None 0.05(.025-0.11)

(.025-0.11)

.044(.025-0.10)

Sr-90 12 0.005 (8/8)

Discharge

.027 (1/4)

None 0.020(.016.032)

(.022.032).009( 005.019)

Cs-137 12 0.08 (0/8)

N/A (0/4)

None all LLD LLD Other Camma 12 0.1 (0/8)

N/A (0/4)

None all LLD LLD

      • I-1".

12 0.05 (4/8)

Discharge 1.76 (3/4)

None 0.72(.05-3.46)

(0.5-3.46) 0.29(.05.73)

NCEE: *** 1-131 results have elevated LLD's due to delay in sample counting times.

M103,85-0059A-HP01

s l

'PJg2 4 ef 4 i

l l

l TABLE RSD-E-03A l

Environmental Radiological Monitoring Program Sununary e

Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1984 to December 31, 1984 Analysis and Lower Limit All All Nonroutine Medium or Total Number of of Indicator Location with Highest Control ~

Reported Pathway Sampled Analyses Performed Detection (a)

Locations Annual Mean Locations Measurements (c)

Unit of Measurement LLD Mean(b)

Name Mean(b)

Mean(b)

Range (b)

Distance & Direction Range (b)

Range (b) l Aquttic Cross Beta 13 1.0 (7/7)

Vicinity of discharge 2.6 (6/6)

None (pci/g k'et) 2.2(1.6-3.1)

& Ludington S Pier (1.9-3.1) 2.3(1.4-3.4) i Sr89 13 0.025 (0/7)

Ludington S Pier 0.039 (1/6)

None I

All LLD

(.025.083) 039(.025.083)

Sr90 13 0.005 (2/7)

Ludington S Pier 007 (2/6)

None 0.006(.005.008)

(.005.009) 007(.005.009)

Camma 13 0.1 (0/13)

N/A None None I

All LLD l

l Cs-137 13 0.08 (0/13)

N/A None None All LLD l

      • I-131 12 0.05 (417)

Vicinity of discharge 1.03 (3/5)

None 0.39(.05-2.0)

(.05-2.0) 0.59(.05-1.94)

a. Nominal Lower Limit of Detection (LLD) as defined in HASL-300 (Rev 8/73), pages D-08-01, 02, and 03,
b. Mean and range based upon detectable measurements only. Fraction of detectable measurents at specified locations is indicated in parentheses.
c. Nonroutine reported measurements are defined in the Palisades Technical Specifications, Section 6.9.3.2.

NOTE: *** 1-131 results have elevated LLD's due to delay in sample counting times.

I MIO385-0059A-HP01

on P;ga.1 of 3 TABLE RSD -E-03D HICH, IDW AND AVERACE CONCENTRATIONS FOR llICHEST AVERACE SAMPLING LOCATION PALISADES NUCLEAR PLANT JANUARY 1, 1984 to DECEMBER 31, 1984

+

Medium Type of Analysis (1)

Location High low Average (5)

Air Cross Beta GR 55 mi NNE 0.087 pCi/m 0.007 pCi/m 0.03 pCi/m S

2 3

I-131 All LLD 02 pC1/m3 Lake Water Cross Beta Discharge 3.6 pC1/1 1.2 pCi/1' 2.4 pC1/1 Cross Alpha Discharge 1 pC$/1 1 pCi/1 1 pC1/1 Tritium Discharge 1570 pCi/1 100 pC1/1 490.8 pC1/1 Drinking Water Cross Beta See Table RSD-E-03A Tritium (4)

See Table RSD-E-03A Well Water Gross Beta State Park (1 mi N) 9.3 pC1/1 2.4 pC1/1 4.8 pCi/1 (1) Minimum detectable level (MDL) = air, gross beta 0.01 pCi/m, I-131 0.02 pCi/m'; water, gross beta 1.0 pCi/1, gross alpha 1.0 8

pCi/1,11-3100 pC1/1; milk, I-1310.5 pCi/1, Sr-89 5.0 pCi/1, gamma isotopic 1.0 pCi/1; crops and sediment, gross beta 1.0 pCi/g, Sr-89 0.025 pCi/g, Sr-90 0.005 pCi/g, gamma isotopic 0.05 pCi/g; some samples may have higher MDLs due to sample size, shipping delays or statistical phenomenon.

(2) Samples collected monthly in season.

(3) Two sampics per location.

(4) Tritium analysis performed on South Haven treated only.

(5) Only samples greater than LLD included in average.

(6) Includes transit dose which averages approximately 6.4 mR/round trip.

1 MIO385-0060A-HP01

_.._. = - -- - _.

. ~.

_~.

I l

Page 2 of 3.

e TABLE RSD -E-03D l

l HIGH, IDW AND AVERAGE CONCENTRATIONS FOR HIGHEST AVERACE SAMPLING IDCATION PALISADES NUCLEAR PLANT JANUARY 1, 1984 to DECEMBER 31, 1984 l

l Medium Type of Analysis (1)

Location High Low Average (5)

Milk I-131 All LLD i.

l Sr-89 All LLD l

Sr-90 GM (5 mi SE) 2.8 pC1/1 2.1 pCi/1 4.2 pC1/1 t

Cs-137 All LLD-Other Gamma All LI.D Gamma Dose (6)

TLD (Monthly)

ST-13.75 mi SE 11.1 mR 3.9 mR 5.9 mR ton perimeter)

{

j TLD (Quarterly)

ST-04 3.5 mi ESE 27.0 mR 16.2 mR 19.5 mR TLD (Annual)

ST-20 0.5 mi S (on perimeter)

Crops (2) '

Gross Beta JS(3.5 mi SE) 7.0 pCi/g 1.0 pCi/g 2.3 pCi/g Sr-89 JS (3.5 mi SE) 0.520 pCi/g 0.025 pCi/g 0.110 pCi/g Sr-90

{[

JS (3.5 mi SE) 0.040 pCi/g 0.005 pCi/g 0.011 pCi/g Cs-137 All LLD Other Gamma All LLD I-131 All LLD MIO385-0060A-IIP 01

a Page 3 of 3 TABLE RSD -E-03D HIGH, II)W AND AVERACE CONCENTRATIONS FOR HIGHEST AVERACE SAMPLING LOCATION PALISADES NUCLEAR PLANT JANUARY 1, 1984 to DECEMBER 31, 1984 Medium Type of Analysis (1)

Location High Low Average (5)

Sediment (3)

Gross Beta Ludington S Pier 13.3 pC1/g 7.5 pCi/g-10.4 pCi/g Sr-89 Discharge 0.11 0.025

.068 Sr-90 Discharge

.032 0.022

.027 Cs-137 All LLD Other Camma All LLD

      • I-131 Discharge 3.46 0.05 1.76 Aquatic Cross Beta Discharge and Ludington S Pier 3.1 pCi/g 1.9 pC1/g 2.6 pCi/g Sr-89 Ludington S Pier 0.083 pCi/g 0.025 pCi/g 0.039 pCi/g Sr-90 Ludington S Pier 0.009 pCi/

0.005 pC1/g 0.007 pCL/g Camma All LLD

      • I-131 Discharge 2.0 0.05 1.03 NOTE: *** I-131 results have elevated LLD's due to delay in sample counting times.

MIO385-0060A-HP01