r TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374ol 1630 Chestnut Street Tower II July 12, 1985 BLRD-50-438/85-11 BLRD-50-439/85-11 U.S. Nuclear Regulatory Commission Region II Attn:

Dr. J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Dear Dr. Grace:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - CRACKED CYLINDER BLOCK ON TDI DIESEL GENERATORS - BLRD-50-438/85-11 AND BLRD-!4-439/85 FINAL REPORT This letter is to correct the content of our cover letter dated July 9, 1985 transmitting the final report on the subject matter. The first paragraph should read as-follows:

The subject deficiency was initially reported to NRC-OIE Inspector Al Ignatonis on March 18, 1985 in accordance with 10 CFR 50.55(e) as

.i.

NCR 4030. This was followed by our first interim report dated April 12, 1985. Enclosed is our final report. We consider 10 CFR Part 21 applicable to this deficiency.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY J. W. Hufham, Manager Licensing and Risk Protection ec:

Mr. James Taylor, Director office of Inspection and Enforcement U.S. Nuclear Regulatory Comnission Washington, D.C.

20555 Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 73 h P

Eh v,

_.._,E.,.,.

op

. _..