_.

m Entergy operrtlin2,Inc.

~

River Bend Station 5485 U. S Highway 61 PO Box 220 St. Francisvdle. LA 70775 Tel 504 336 6225 Fax 504 635 5068 Rick J. King i

Deector Nuclear Safety & Regulatory Affairs I

l October 31,1996 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-37 Washington, D.C. 20555 l

l

Subject:

River Bend Station - Unit 1 License No. NPF-47 Docket No. 50-458 Update To Emergency Response Data System Data Point Library l

l File Nos.:

G9.5, Gl.13.6.3 RBF1-96-0412 l

RBG-43340 l

Gentlemen:

Pursuant 10CFR50, Appendix E, VI.3.a., enclosed is an update to the River Bend Station (RBS)

Emergency Response Data System (ERDS) Data Point Library. Fourteen data points contain some degree of change to the " Unique System Desc." field. One of the changes also added verbiage to the

" Level Reference Leg" field. Approximately ten of the changes were not submitted within 30 days as required by this subject regulation. The majority of changes which were not submitted within 30 days I

resulted from the RBS implementation of improved technical specifications in October of 1995. The submittal timefame inconsistency was identified by RBS personnel and is being addressed within the RBS corrective action program.

Should you have any questions, please contact Mr. David N. Imrfing at (504) 381-4157.

Sin. rely, 4

RJK/WJF/kv attachment I

l 060048 9611060299 961031 i

PDR ADOCK 05000458 F

PDR

t I

i l

l t

Update to ERDS Data Point Library l

October 31,1996 i

RBF1-96-0412 RBG-43340 j

Page 2 of 2 l

j l

cc:

U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 NRC Sr. Resident Inspector P. O. Box 1050 St. Francisville, LA 70775 David Wigginton l

U.S. Nuclear Regulatory Commission M/S OWFN 13-H-15 i

Washington, DC 20555 1

Mr. J. R. Joliceur ERDS Project Manager j

l U. S. Nuclear Regulatory Commission i

Mail Stop T4A43 Washington, D. C. 20555 i

1 l

l r

l l

i ATTACHMENT TO RBG-43340 i

page 1 of 29 i

i l

1 1

i i

l l

ERDS DATA POINT LIBRARY (DPL)

(28 Data Points) l l

4 a

l l

=

_ -. _. - -, _ _ ~

1 ATTACILMENT TO RBG-43340 l*

page 2 0f 29 Dite:

10/31/96 l

I Reactor Unit:

RB1 D:ts Feeder:

NOT APPLICABLE (N/A) l NRC ERDS Parameter:

DW TEMP Poi:t ID:

DRYWELLT t

Plant Spec Point Desc.:

DRYWELL TEMPERATURE l

Generic /Cond Desc.:

DRYWELL ATMOSPHERIC TEMPERATURE A 2. log / Digital:

ANALOG l

Ergr Units / Dig States:

DEGF I

t EIgr Units Conversion:

N/A i

Mi.imum lastr Range:

40 l

Maimum Instr Range:

440 Zero Point

Reference:

N/A Ref:rence Point Notes:

N/A i

PROC or SENS:

PROC Number of Sensors:

2 How Processed:

AVERAGE l

Se:sor Locations:

DRYWELL i

i l

Alirm/ Trip Set Points:

N/A NI Detector Power Supply l

Cut-off Power Level:

N/A NI Detector Power Supply T :rn-on Power Level:

N/A I:stnament Failure Mode:

N/A Temperature Compensation For DP Transmitters:

N/A Lev:1 Reference Leg:

N/A Urique System Desc.:

DRYWELL AVERAGE AIR TEMP ALLOWABLE 5145 DEGREES F.

REFERENCE RBS TECH SPEC 3.6.5.5.

I l

ATTACHMENT TO RBG-43340 page 3 of 29 Dite:

10/31/96 l

Reactor Unit:

RBI l

his Freder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

NIPOWER RNG l

PoiIt ID:

RXPOWER Plant Spec Point Desc.:

REACTOR POWER Generic /Cond Desc.:

NUCLEAR INSTRUMENT POWER RANGE A alog/ Digital:

ANALOG l

Ergr Units / Dig States:

Elgr Units Conversion:

2894 MEGA WATE THERMAL = 100%

Mirimum Instr Range:

0 Mr.ximum Instr Range:

125 Zero Point

Reference:

N/A Ref;rencr. Point Notes:

N/A PROC or SENS:

PROC i

l Number of Sensors:

SEE BELOW j

1 How Processed:

COMPLEX l

Sersor Locations:

IN REACTOR CORE i

l l

Al:rmffrip Set Points:

N/A j

l l

NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Tar.:-on Power Level:

N/A 1

I:stivment Failure Mode:

LOW 1

Temperature Compensation For DP Transmitters:

N/A Level Reference leg:

N/A 1

{

U11gue System Desc.:

111% THERMAL POWER TRIP REFERENCE RBS TRM TABLE 3.3.1.1-1.

l l

I

l ATTACHNENT TO RBG-43340 page 4 of 29 Date:

10/31/96 l

(

Reactor Unit:

RBI D:ta Feeder:

NOT APPLICABLE (N/A) l NRC ERDS Parameter:

REAC VES LEV Poilt ID:

RPVWTRLVL l

Plant Spec Point Desc.:

RPV WATER L.EVEL l

j Generic /Cond Desc.:

REACTOR VESSEL WATER LEVEL i

A~alog/ Digital:

ANALOG l

Ergr Units / Dig States:

IN E:gr Units Conversion:

N/A l

Milimum Instr Range:

-310 Mnimum Instr Range:

400 Zero Point

Reference:

MSSKRT l

RefIrence Point Notes:

N/A l

PROC or SENS:

PROC l

l Number of Sensors:

5 ZONES He,7 Processed:

COMPLEX SeIsor Locations:

N/A Al rm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply i

Tarn-on Power Level:

N/A 1:strument Failure Mode:

LOW I

Temperature Compensation l

F:r DP Transmitters:

YES 1

Lev;l Reference Leg:

STEAM COND POT WITH CRD BACKFILL l

Ucique System Desc.:

INSTRUMENT ZERO 162 INCHES ABOVE TOP OF ACTIVE FUEL. REFERENCE RBS USAR FIGURE 5.2-6.

l l

t

ATTACHMENT TO RBG-43340 page 5 of 29 Date:

06/03/92 Reactor Unit:

RBI D t3 Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

MAIN FD FLOW PriIt ID:

FEEDWATER Plant Spec Point Desc.:

FEEDWATER TOTAL FLOW Generic /Cond Desc.:

FEEDWATER FLOW INTO THE REACTOR SYSTEM Aralog/ Digital:

ANALOG Ergr Units / Dig States:

MLB/HR E:gr Units Conversion:

N/A Mi:Imum Instr Range:

J Mr.ximum Instr Range:

15 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

Sf,h 3 Number of Sensors:

1 How Processed:

N/A Se:sor Locations:

TURBINE BASEMENT Alirm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Ttrn-on Power Level:

N/A listrument Failure Mode:

LOW Temperature Compensation Far DP Transmitters:

N/A Level Reference Leg:

N/A Urique System Desc.:

REFERENCE USAR FIGURE 1.1-1, USAR FIGURE 5.1-1

A'ITACHMENT TO RBG-43340 page 6 of 29 Date:

06/03/92 l

Reactor Unit:

RBI Dats Feeder:

NOT APPLICABLE (N/A) l NRC ERDS Parameter:

RCIC FLOW i

Poi t ID:

RCIC i

Pl=t Spec Point Desc.:

RCIC DISCHARGE FLOW Generic /Cond Desc.:

REACTOR CORE ISOLATION COOLING FLOW Aralog/ Digital:

ANALOG Ergr Ifnits/PJg States:

GPM Eigr Units Conversion:

N/A MI:.imum Instr Range:

0 Mnimum Instr Range:

800 Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS j

l Nrmber of Sensors:

1 llow Processed:

N/A I

Sensor Locations:

AUX BUILDING BASEMENT 4

Alirm/ Trip Set Points:

N/A NI Detector Power Supply Cat-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

LOW Temiwrature Compensation l

Far DP Transmitters:

N/A lael Reference Leg:

N/A l

Ulique System Desc.:

MINIMUM PRESSURE FOR RCIC IS 150 PSIG l

2 RCIC PROVIDES 600 GPM AT 1192 PSI r

l REFERENCE RBS USAR SECTION 5.4.6.2.2.2 1

.~

l ATTACHMENT TO RBG-43340 page 7 of 29 D:te:

10/31/96 l

Reactor Unit:

RBI Dits Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

RCS PRESSURE Polit ID:

RPV PRES Plant Spec Point Desc.:

REACTOR PRESSURE Generic /Cond Desc.:

REACTOR COOLANT SYSTEM PRESSURE l

l A alog/ Digital:

ANALOG Ergr Units / Dig States:

PSIG l

Ergr Units Conversion:

N/A Mirimum Instr Range:

0 l

Mr.ximum Instr Range:

1500 i

1 Zero Point

Reference:

N/A l

Refrrence Point Notes:

N/A PROC or SENS:

PROC Number of Sensors:

SEE BELOW How Processed:

COMPLEX Se sor Locations:

N/A Alarm / Trip Set Points:

N/A l

NI Detector Power Supply l

Cut-off Power Level:

N/A NI Detector Power Supply Trrn-on Power Level:

N/A i

l I:strument Failure Mode:

N/A l

Temperature Compensation For DP Transmitters:

N/A Level Reference Leg:

N/A I

UsIque System Dest.:

SRV-1 (PSIG OPENS-1103), SRV-8 (PSIG OPENS 1113), SRV-7 (PSIG OPENS l

1123). REFERENCE RBS TECH SPEC 3.3.6.4, ATWS TRIP OF RECIRC PUMPS 1127 PSIG. REFERENCE RBS TECH SPEC TABLE 3.3.4.2-1.

l l

i

~

ATTACHMENT TO RBG-43340 page 8 of 29 D te:

10/31/96 l

1 Reactor Unit:

RBI DIts Feeder:

NOT APPLICABLE (N/A)

]

NRC ERDS Parameter:

CR SPRAY FL Poilt ID:

HPCS Plzt Spec Point Desc.:

HPCS PUMP DISCHARGE FLOW Generic /Cond Desc.:

HIGH PRESSURE CORE SPRAY FLOW Aralog/ Digital:

ANALOG Ergr Units / Dig States:

GPM Ergr Units Conversion:

N/A Mirimum Instr Range:

0 Mrximum Instr Range:

7000 Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS 1

Number of Sensors:

1 Haw Processed:

N/A Sexsor Locations:

AUX BUILDING BASEMENT Altrmffrip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A I

I strument Failure Mode:

LOW Temperature Compensation F r DP Transmitters:

N/A Level Reference Leg:

N/A Urique System Desc.:

HPCS PROVIDES 467 GPM AT 1177 PSID,1400 GPM AT 1147 PSID,4900 GPM l AT 200 PSID. REFERENCE RBS USAR TABLE 6.3-2B.3

ATTACHMENT TO RBG-43340 page 9 of 29 4

Dite:

10/31/ %

l Reactor Unit:

RBI D:ts Feeder:

NOT APPLICABLE (N/A) 5 NRC ERDS Parameter:

LPCI FLOW P litID:

RHRA Plut Spec Point Desc.:

RESIDUAL HEAT REMOVAL TRAIN A FLOW Generic /Cond Desc.:

LOW PRESSURE COOLANT INJECTION FLOW Aralog/ Digital:

ANALOG Engr Units / Dig States:

GPM Ergr Units Conversion:

N/A Miz.imum Instr Range:

0 Miximum Instr Range:

7000 Zero Point

Reference:

N/A Reference Point Notes:

N/A P

PROC or SENS:

SENS I

Number of Sensors:

1 How Processed:

N/A Sersor Locations:

AUX BUILDING BASEMENT Alirm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A I:strument Failure Mode:

LOW l

Temperature Compensation Fcr DP Transmitters:

N/A Levti Reference Leg:

N/A 1

Unique System Desc.:

FLOW MAY COMMENSE AT 225 PSID l

14900 GPM AT 20 PSID l

REFERENCE RBS USAR TABLE 6.3-2B.1

ATTACHMENT TO RBG-43340 page 10 of 29 Dite:

10/31/96 l

f Reactor Unit:

RB1 l

D:ts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

LPCI FLOW PoiIt ID:

RIIRB Plant Spec Point Dese.:

RESIDUAL HEAT REMOVAL TRAIN B FLOW l

Generic /Cond Desc.:

LOW PRESSURE COOLANTINJECTION FLOW Azalog/ Digital:

ANALOG Ergr Units / Dig States:

GPM Ergr Units Conversion:

N/A Mirimum Instr Range:

0 Mrximum Instr Range:

7000 Zers Point

Reference:

N/A Reference Point Notes:

N/A I

PROC or SENS:

SENS Number of Sensors:

1 l

How Processed:

N/A Se:sor Locations:

AUX BUILDING BASEMENT i

Al:rmffrip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Tu rn+n Power Level:

N/A I strument Failure Mode:

LOW l

Temperature Compensation F:r DP Transmitters:

N/A l

Level Reference Leg:

N/A U:dque System Desc.:

FLOW MAY COMMENSE AT 225 PSID I4900 GPM AT 20 PSID l

REFERENCE RBS USAR TABLE 6.3-2B.1

ATTACHMENT TO RBG-43340 pace 1I of 29 D:te:

10/31/96 l

Reactor Unit:

RBI Dits Feeder:'

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

LPCI FLOW Poilt ID:

RHRC Plant Spec Point Desc.:

RESIDUAL HEAT REMOVAL TRAIN C FLOW Generic /Cond Desc.:

LOW PRESSURE COOLANT INJECTION FLOW A= log / Digital:

ANALOG E:gr Units / Dig States:

GPM EIgr Units Conversion:

N/A Mirimum Instr Range:

0 Malmum Instr Range:

7000 Zero Point

Reference:

N/A Ref:rence Point Notes:

N/A PROC or SENS:

SENS Number of Sensors:

I How Processed:

N/A Sensor Locations:

AUX BUILDING BASEMENT Allrm/ Trip Set Points:

N/A NI Detector Power Supply Ctt-off Power Level:

N/A NI Detector Power Supply Tern-on Power Incl:

N/A Instrument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Level Reference Leg:

N/A U ique System Desc.:

FLOW MAY COMMENSE AT 225 PSID l

14900 GPM AT 20 PSID l

REFERENCE RBS USAR TABLE 6.3-28.I

ATTACHMENT TO RBG-43340 page 12 of 29 D:te:

10/31/96 l

Reactor Unit:

RBI D ta Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

CR SPRAY FL Poilt ID:

LPCS Plant Spec Point Desc.:

LPCS PUMP DISCHARGE FLOW Generic /Cond Desc.:

LOW PRESSURE CORE SPRAY FLOW l

Analog / Digital:

ANALOG Ergr Units / Dig States:

GPM EIgr Units Conversion:

N/A Mirimum Instr Range:

0 Mulmum Instr Range:

8000 Zero Point

Reference:

N/A 7

Refirence Point Notes:

N/A i

{

PROC or SENS:

SENS Number of Sensors:

1 l

H:r.r Processed:

N/A 1

j Sensor Locations:

AUX BUILDING BASEMENT j

A1:rm/ Trip Set Points:

N/A NI Detector Power Supply i

Cet-off Power Level:

N/A NI Detector Power Supply Tern-on Power Level:

N/A Instnament Failure Mode:

LOW Temperature Compensation Far DP Transmitters:

N/A l

l Lev;1 Reference Leg:

N/A Unique System Desc.:

LPCS FLOW MAY COMMENCE AT 265 PSID l

4900 GPM AT 113 PSID l

REFERENCE RBS USAR TABLE 6.3-2B.2

ATI'ACHMENT TO RBG-43340 page 13 of 29 D:t :

06/03/92 Reactor Unit:

RBI D:t3 Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

DW FD SMPLV Poirt ID:

DRYWELLS Plant Spec Point Desc.:

DRYWELL SUMP LEVEL Generic /Cond Desc.:

DRYWELL FLOOR DRAIN SUMP LEVEL Arlog/ Digital:

ANALOG E,igr Units / Dig States:

IN H2O l

Ergr Units Conversion:

12.27 GALLONS / INCH j

)

Minimum Instr Range:

0 Maimum Instr Range:

36 Zero Point

Reference:

N/A l

Ref:rence Point Notes:

N/A 1

PROC or SENS:

SENS Number of Sensors:

1 H:w Processed:

N/A SeIsor Locations:

DRYWELL BASEMENT Al rm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Level Reference Leg:

N/A Unique System Desc.:

i

A'ITACHMENT TO RBG-43340 page 14 of 29 D:te:

06/03/92

]

Reactor Unit:

RBI D:ts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

RADIOACTIVITY OF RELEASED GASSES PohtID:

MAIN PLANT Plant Spec Point Desc.:

MAIN PLANT STACK j

Generic /Cond Desc.:

MAIN PLANT GASEOUS EFFLUENT i

A alog/ Digital:

ANALOG 4

4 E gr Units / Dig States:

uC1/S E?gr Units Conversion:

N/A Milimum Instr Range:

10 j

M:.simum Instr Range:

10" Zero Point

Reference:

N/A RefIrence Point Notes:

N/A 4

PROC or SENS:

SENS N1mber of Sensors:

1 How Processed:

N/A Sensor Locations:

MAIN PLANT STACK 1

At:rm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A 1

NI Detector Power Supply Turn-on Power Level:

N/A IIstrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

N/A Levil Reference Leg:

N/A Unique System Desc.:

r ATTACHMENT TO RBG-43340 page 15 of 29 D:ta:

06/03/92 1

Reactor Unit:

RB1 l

e D:ta Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:.

RADIOACTIVITY OF RELEASED GASSES P: lit ID:

FUEL BLDG l

i Plant Spec Point Desc.:

FUEL BUILDING STACK 4

Generic /Cond Desc.:

FUEL BUILDING GASEOUS EFFLUENT i

Analog / Digital:

ANALOG Ergr Units / Dig States:

uCI/S Eigr Units Conversion:

N/A Minimum Instr Range:

10 i

Malmum Instr Range:

10" Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS i

i l

i Number of Sensors:

1 J

i How Processed:

N/A j

l Seisor Locations:

FUEL BUILDING STACK i

Al rm/ Trip Set Points:

N/A 4

j NI Detector Power Supply l

Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A 1

IIstrument Failure Mode:

LOW Temperature Compensation Far DP Transmitters:

N/A Level Reference Leg:

N/A Usique System Desc.:

A'ITACIEENT TO RBG-43340

~

page 16 of 29 D te:

06/03/92 l

l Reactor Unit:

RBI l

l Dit: Feeder:

NOT APPLICABLE (N/A) l l

NRC ERDS Parameter:

RADIOACTIVITY OF RELEASED GASSES i

P: lit ID:

RADWASTE l

Plant Spec Point Desc.:

RADWASTE BUILDING STACK l

1 l

Generic /Cond Desc.:

RADWASTE BUILDING GASEOUS EFFLUENT l

A= Jog / Digital:

ANALOG Ergr Units / Dig States:

uCI/S Esgr Units Conversion:

N/A 1

Mirimum Instr Range:

10 l

l M:ximum Instr Range:

10" Zero Point

Reference:

N/A Ref4rence Point Notes:

N/A PROC or SENS:

SENS Number of Sensors:

1 Hm Frocessed:

N/A l

Se sor Locations:

RADWASTE BUILDING STACK A1:rm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Tarn-on Power Level:

N/A Intrument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A l

Level Reference Leg:

N/A Urique System Desc.:

l

ATTACHMENT TO RBG-43340 page 17 of 29 Dite:

10/31/96 l

l Reactor Unit:

RBI Dit:: Feeder:

NOT APPLICABLE (N/A) l l

NRC ERDS Parameter:

DW PRESS j

l PoIIt ID:

DRYWELLP Plant Spec Point Desc.:

DRYWELL PRESSURE Generic /Cond Desc.:

DRYWELL ATMOSPHERIC PRESSURE Arlog/ Digital:

ANALOG l

Eigr Units / Dig States:

PSIG Engr Units Conversion:

N/A Mirimum Instr Range:

0 M;.zimum Instr Range:

75 Zero Point

Reference:

N/A Refrrence Point Notes:

N/A PROC or SENS:

PROC Number of Sensors:

4 How Processed:

AVERAGE Se:sor Locations:

DRYWELL AIIrm/ Trip Set Points:

N/A NI Detector Power Supply Cut-ofY Power Level:

N/A NI Detector Power Supply Tarn-on Power Level:

N/A listivment Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Level Refarence Leg:

N/A I

l Urique System Desc.:

DRYWELL PRESSURE REACTOR TRIP SETPOINT 1.68 PSID.

I REFERENCE RBS TRM TABLE 3.3.1.1-1.

i l

i

_. ~

l ATTACHMENT TO RBG-43340 4

page 18 of 29 Dite:

10/31/96 l

Reactor Unit:

RBI I

D ts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

SP TEMP 1

Poilt ID:

SUPPOOLT Plant Spec Point Desc.:

SUPPRESSION POOL TEMPERATURE Generic /Cond Desc.:

SUPPRESSION POOL WATER TEMPERATURE

{

A alog/ Digital:

ANALOG Engr Units / Dig States:

DEGF Ergr Units Conversion:

N/A Mirimum Instr Range:

0 i

M ximum Insir Range:

200 l

l N/A

. Zero Point

Reference:

j Refirence Point Notes:

N/A PROC or SENS:

PROC Number of Sensors:

SEE BELOW l

i Haw Processed:

AVERAGE i

i Sensor Locations:

CONTAINMENT SUPPRESSION POOL 1

Altrm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power Level:

N/A i

N1 Detector Power Supply Turn-on Power level:

N/A I:strument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Lev:1 Reference Leg:

N/A Uzique System Desc.:

REFERENCE RBS TECH SPEC 3.6.2.1 l

AT 110 DEGREES F MUST PLACE REACTOR MODE SWITCH IN SHUTDOWN POSITION.

ATTACHhENT TO RBG-43340 page 19 of 29 D;te:

10/31/96 l

Reactor Unit:

RBI D:ta Feeder:

NOT APPLICABLE (N/A) i NRC ERDS Parameter:

SP LEVEL l

PoiIt ID:

SUPPOOLL l

1 Plant Spec Point Desc.:

SUPPRESSION POOL LEVEL l

i Generic /Cond Desc.:

SUPPRESSION POOL WATER LEVEL l

A:alog/ Digital:

ANALOG Eigr Units / Dig States:

IN E;gr Units Conversion:

4392 GALLONS / INCH 1

Mirimum Instr Range:

0 M ximum Instr Range:

264 Zero Point

Reference:

N/A i

Reference Point Notes:

N/A j

PROC or SENS:

PROC Nzmber of Sensors:

4 How Processed:

AVERAGE Se:sor Locations:

CONTAINMENT SUPPRESSION POOL Al:rm/ Trip Set Points:

N/A NI Detector Power Supply Cet-off Power Level:

N/A NI Detector Power Supply Tarn-on Power Ixtel:

N/A lastrument Failure Mode:

LOW 1

Tcmperature Compensation j

Ftr DP Transmitters:

N/A Imel Reference Leg:

N/A Urique System Desc.:

137,571FT'(1929031 GALLONS)

INITIAL POOL LEVEL - 19'6" MINIMUM,20' MAXIMUM l

REFERENCE RBS TECH SPECS SECTION 3.6.2.2 l

~

ATTACHMENT TO RBG-43340 page 20 of 29 D:te:

06/03/92 Reactor Unit:

RB1 D:ts Feeder:

NOT APPLICAllLE (N/A)

NRC ERDS Parameter:

CST LEVEL Poilt ID:

CSTLEVEL PI:nt Spec Point Desc.:

CONDENSATE STORAGE TANK LEVEL Generic /Cond Desc.:

CONDENSATE STORAGE TANK LEVEL An' Jog / Digital:

ANALOG E gr Units / Dig States:

FEET Ergr Units Conversion:

15500 GALLONS / FOOT Millmum Instr Range:

0 Mrsimum Instr Range:

40 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

SENS Nimber of Sensors:

1 Hn Processed:

N/A Scisor Locations:

CST Alirm/ Trip Set Points:

N/A NI Detector Power Supply Cut-off Power 12 Vel:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Izstrument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Level Reference Leg:

N/A Urique System Desc.:

LAST 125000 GALLONS IN CST FOR RCIC AND IIPCS ONLY.

REFERENCE RBS USAR SECTION 9.2.6.2

ATTACHMENT TO RBG-43340 page 21 of 29 Date:

06/03/92 Reactor Unit:

RB1 Dita Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

WIND SPEED AT Tile REACTOR SITE i

Point ID:

WINDSPEEDU i

Pirt Spec Point Desc.:

WIND SPEED 150 FOOT Generic /Cond Desc.:

UPPER WIND SPEED A= Jog / Digital:

ANALOG Ergr Units / Dig States:

MPH Ergr Units Conversion:

N/A Mlzimum Instr Range:

0 Maximum Instr Range:

100 Zero Point Referetee:

N/A Ref rence Point Notes:

N/A PROC or SENS:

SENS Number of Sensors:

1 Ilow Processed:

N/A Sensor Locations:

METEOROLOGICAL TOWER A!:rmfTrip Set Points:

N/A NI Detector Power Supply Cit-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A listrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

N/A Level Reference Leg:

N/A Urique System Desc.:

=.

ATTACHMENT TO RBG-43340 l

page 22 of 29 Octe:

06/03/92 l

Reactor Unit:

RB1 Dats Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

WIND SPEED AT THE REACTOR SITE t

l Poiit ID:

WINDSPEEDL 1

l Plant Spec Point Desc.:

WIND SPEED 30 FOOT Generic /Cond Desc.:

LOWER WIND SPEED An. log / Digital:

ANALOG Eigr Units / Dig States:

MPH Ergr Units Conversica:

N/A Minimum Instr Range:

0 i

Maximum Instr Range:

100 Zero Point

Reference:

N/A Ref rence Point Notes:

N/A PROC or SENS:

SENS Nrmber of Sensors:

1 How Processed:

N/A Sensor Locations:

METEOROLOGICAL TOWER A!:rmffrip Set Points:

N/A NI Detector Power Supply Cat-off Power I.evel:

N/A NI Detector Power Supply Turn-on Power Level:

N/A IIstmment Failure Mode:

LOW Temperature Compensation For DP Transmitters:

N/A l

Level Reference Leg:

N/A l

Urique System Desc.:

i

o ATTACHMENT TO RBG-43340 page 23 0f 29 Cite:

06/03/92

+

t Reactor Unit:

RBI C ts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

WIND DIRECTION AT THE REACT 0k SITE I

I Poirt ID:

V'INDDIRU I

l i

l Plant Spec Point Desc.:

WIND DIRECTION 150 FEET I

l Generic /Cond Desc.:

UPPER WIND DIRECTION l

Aralog/ Digital:

ANALOG Ener Units / Dig States:

DEGREES i

Eagr Units Conversion:

N/A Minimum Instr Range:

0 l

Mr.simum Instr Range:

360 1

Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS l

Number of Sensors:

1 How Pmcessed:

N/A Sensor Locations:

METEOROLOGICAL TOWER Alirm/ Trip Set Points:

N/A NI Detector Power Supply l

Cut-off Power Incl:

N/A NI Detector Power Supply Tern-on Power Level:

N/A 1:strument Failun Mode:

LOW l

Temperatum Compensation F r DP Transmitters:

N/A Inci Reference Leg:

N/A l

Utique System Desc.:

0 DEGREES IS WIND FROM THE NORTH. A WIND BLOWING FROM THE SOUTH WOULD BE 180 DEGREES.

I

?

ATTACHMENT TO RBG-43340 e

page 24 cf 29 D:te:

06/03/92 Reactor Unit:

RB1 l

Ccts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

WIND DIRECTION AT THE REACTOR SITE l

Peint ID:

WINDDIRL -

l j

Plant Spec Point Desc.:

WIND DIRECTION 30 FOOT l

Generic /Cond Desc.:

LOWER WLND DIRECTION l

Analog / Digital:

ANALOG 1

Ergr Units / Dig States:

DEGREES i

Engr Units Conversion:

N/A Minimum Instr Range:

0 i

l M:simum Instr Range:

360 l

Zero Point

Reference:

N/A Ref; ence Point Notes:

N/A i

i PROC or SENS:

SENS t

i l

Number of Sensors:

1 How Processed:

N/A Seasor Locations:

METEOROIOCICAL TOWER y

Al rm/ Trip Set Points:

N/A l

NI Detector Power Supply Cut-off Power Level:

N/A l

NI Detector Power Supply l

Tarn-on Power level:

N/A i

1:strument Failure Mode:

LOW t

Tcmperature Compensation 4

Fcr DP Transmitters:

N/A Level Reference Leg:

N/A i

Urique System Desc.:

0 DEGREES IS WIND FROM THE NORTH. A WIND BLOWING FROM THE SOUTH WOULD BE 180 DEGREES.

i l

l.

_ _ _ _. _ _. _ _. -.. _... _... _. _ _. ~. - _ _ _.. _

_.m P

ATTACHMENT TO RBG-43340 page 25 of 29 i

D:te:

06/03/92 Reactor Unit:

RBI Dcts Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

AIR STABILITY AT THE REACTOR SITE Poilt ID:

STABCLASS j

Plant Spec Point Desc.:

AIR STABILITY (DELTA TEMP)

Generic /Cond Desc.:

STABILITY CLASS Ana og/ Digital:

ANALOG j

Elgr Units / Dig States:

STABA Eigr Units Conversion:

N/A Minimum Instr Range:

1 M ximum Instr Range:

7 Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS l

Nzmher of Sensors:

1 How Processed:

N/A i

Sensor Locations:

METEOROLOGICAL TOWER t

Al:rm/ Trip Set Points:

N/A NI Detector Power Supply Cct-off Power Level:

N/A NI Detector Power Supply Tern-on Power Level:

N/A I:strument Failure Mode:

LOW I

Temperature Compensation For DP Transmitters:

N/A Level Reference leg:

N/A Urique System Desc.:

STABILITY CLASS COMPUTED FROM DELTA TEMPERATURES BETWEEN 150 FOOT AND 30 FOOT. STABILITY CLASS 1 CORRESPONDS TO A AND CLASS 7 CORRESPONDS TO G.

4

a ATTACHMENT TO RBG-43340 page 26 of 29 Cite:

10/31/96 l

Reactor Unit:

RBI Dita Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

NI SOURC RNG Poilt ID:

SRMCNT Plzt Spec Point Desc.:

SOURCE RANGE MONITOR COUNT RATE Generic /Cond Desc.:

SOURCE RANGE NUCLEAR INSTRUMENT Aralog/ Digital:

ANALOG E;gr Units / Dig States:

CPS EIgr Units Conversion:

N/A Minimum Instr Range:

10

Mr.ximum Instr Range:

10 '

Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS Number of Sensors:

1 How Processed:

N/A 1

i Sensor Locations:

REACTOR CORE Al:rm/ Trip Set Points:

N/A i

NI Detector Power Supply C;t-off Power Level:

N/A NI Detector Power Supply Trrn-on Power Incl:

N/A I:strument Failure Mode:

LOW Temperature Compensation j

F:r DP Transmitters:

N/A I

Level Reference Leg:

N/A UIique System Desc.:

ROD BLOCK 1 X 10' CPS.

REFERENCE RBS TRM TABLE 3.3.2.1-1 NOTE: OPERATOR ACTION TO INSERT SRM AFTER SCRAM

e ATTACHMENT TO RBG-43340 page 27 of 29 i

D:te:

10/31/96 l

l Reactor Unit:

RBI i

D:(2 Feeder:

NOT APPLICABLE (N/A) i l

NRC ERDS Parameter:

CND A/E RAD i

Point ID:

OFFGAS 1

Plant Spec Point Desc.:

OFFGAS PRETREATMENT ROD Generic /Cond Desc.:

A alog/ Digital:

ANALOG E gr Units / Dig States:

Mr/H Eigr Units Conversion:

N/A Mkimum Instr Range:

1 Mrximum Instr Range:

10' Zero Point

Reference:

N/A Ref;rence Point Notes:

N/A PROC or SENS:

SENS i

Nrmber of Sensors:

1 How Processed:

N/A l

Se sor Locations:

OFFGAS BUILDING Al:rm/ Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Level Reference Leg:

N/A l

Uzique System Desc.:

-SYSTEM DESIGN REFERENCE RBS USAR TABLE 11.3-2.

-OFFGAS PRETREAT SETPOINT 1.5X FULL POWER PROCESS l

BACKGROUND RADIATION LEVEL (ALARM ONLY) NOT TO EXCEED l

TECH. SPEC. 3.7.4. REFERENCE RBS TRM TABLE 3.3.7.8.2-1.

~.. _.

l e

ATTACHMENT TO RBG-43340 page 28 of 29 1

l D:te:

06/03/92

)

l Reactor Unit:

RBI Cats Feeder:

NOT APPLICABLE (N/A)

NRC ERDS Parameter:

DW RAD Point ID:

DRYRAD Plant Spec Point Desc.:

DRYWELL RADIATION POST ACCIDENT MONITOR Generic /Cond Desc.:

RADIATION LEVELIN THE DRYWELL Ardog/ Digital:

ANALOG E gr Units / Dig States:

R/HR E2gr Units Conversion:

N/A Minimum Instr Range:

0 i

l Mulmum Instr Range:

10' l

Zero Point

Reference:

N/A l

RefIrence Point Notes:

N/A l

l l

PROC or SENS:

SENS l

Number of Sensors:

1 t

l How Processed:

N/A 1

l Sensor Locations:

DRYWELL Al:rmffrip Set Points:

N/A NI Detector Power Supply Cat-off Power Level:

N/A

'I NI Detector Power Supply Turn-on Power Level:

N/A I strument Failure Mode:

LOW Temperature Compensation F:r DP Transmitters:

N/A Lev:1 Reference Leg:

N/A t

Udque System Desc.:

REFERENCE RBS USAR TABLE 12.3-1 l

l

_ _... _ _ _ ~.

o i

ATTACHMENT TO RBG-43340 a

e l-page 29 0f 29 j

l D:t::

06/03/92 l

1 i

Reactor Unit:

RB1 l

t Cats Feeder:

NOT APPLICABLE (N/A) l NRC ERDS Parameter:

MN STEAM RAD Poilt ID:

CNTRAD 4

i Plant Spec Point Desc.:

CONTAINMENT RADIATION POST ACCIDENT MONITOR Generic /Cond Desc.:

RADIATION LEVEL IN CONTAINMENT Arlog/ Digital:

ANALOG l

I EIgr Units / Dig States:

R/HR l

Eigr Units Conversion:

N/A Miiimum Instr Range:

0 i

M:ximum Instr Range:

10' Zero Point

Reference:

N/A i

Ref:rence Point Notes:

N/A j

PROC or SENS:

SENS 1

I Nr.mber of Sensors:

1 How Processed:

N/A l

]

Selsor Locations:

CONTAINMENT Alirm/ Trip Set Points:

N/A l

NI Detector Power Supply Cat-off Power Level:

N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

N/A Level Reference Leg:

N/A i

i

+

UzIque System Desc.:

REFERENCE RBS USAR TABLE 12.3-1.

I a

NOTE: REACTOR VESSEL SAFETY RELIEF VALVES VENT TO SUPPRESSION POOL LOCATED IN CONTAINMENT u