Insp Rept 50-302/96-11 on 960908-1005.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maintenance, & Plant Support
ML20129H731
Person / Time
Site: Crystal River 
Issue date: 10/30/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20129H731 (30)
Notice of Violation from Insp on 960908-1005.Violation Noted:Failure of Clearance for Work Request Nu 0337713 to Require Tripping Fuel Racks Prior to Opening Air Supply Isolation Valve Resulted in Inadvertent Start of Generator
ML20129H726
Person / Time
Site: Crystal River 
Issue date: 10/30/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20129H726 (2)
Forwards Insp Rept 50-302/96-11 on 960908-1005 & NOV
ML20129H720
Person / Time
Site: Crystal River 
Issue date: 10/30/1996
From: Landis K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: BEARD P M
FLORIDA POWER CORP.
References