Forwards RAI Re Amend 4.1 to Second 10 Yr Interval ISI Program
ML20129F658
Person / Time
Site: Cooper 
Issue date: 10/24/1996
From: Hall J
NRC (Affiliation Not Assigned)
To: Horn G
NEBRASKA PUBLIC POWER DISTRICT
References
TAC-M95833, NUDOCS 9610290186
Download: ML20129F658 (6)


Text

__.

So ~ 3W pu ntu y~

,t UNITED STATES E

NUCLEAR REGULATORY COMMISSION If WASHINGTON, D.C. 2066H201

.....,o October 24, 1996 Mr. G. R. Horn Senior Vice President of Energy Supply Nebraska Public Power District 1414 15th Street Columbus, NE 68601

SUBJECT:

COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT 4.1 TO THE SECOND 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM (TAC NO. M95833)

Dear Mr. Horn:

By letter dated June 20, 1996, the Nebraska Public Power District (NPPD) submitted Amendment 4.1 to the Second 10-Year Interval Inservice Inspection (ISI) Program for the Cooper Nucle:r Station (CNS). Amendment 4.1 contains one revised and four new requests for relief from the ASME Code Section XI requirements for NRC review and approval, in accordance with the requirements of 10 CFR 50.55a. The need for these relief requests was identified during

~

the refueling outage ending December 30, 1995, the last refueling outage in the second interval.

The NRC staff, with technical assistance from its contractor, the Idaho 4

National Engineering Laboratory, has reviewed and evaluated the information i

provided in the above submittal.

Based upon that review, the staff will require additional information in order to complete its review of the relief requests associated with Amendment 4.1 to the Second 10-year Interval ISI 4

Program for CNS.

The staff's request for additional information (RAI) is attached.

In order for the staff to complete its review in a timely manner, we request that you submit a response to the attached RAI within 60 days of i

the receipt of this letter.

In addition, to expedite our review, please send a copy of your response to:

Michael T. Anderson INEL Research Center j

2151 North Boulevard PO Box 1625 Idaho Falls, Idaho 83415-2209 4

l 4

290010 hho Y C$TB Y da 9610290186 961024 u

PDR ADOCK 05000298 0

PDR

a

...a.

-.x

-. + -. - -

---a n.

I i

Mr. G. R. Horn l If you have any questions regarding this request, please call me at (301) 415-1336.

i Sincerely, l

m>L j

i s R. Hall, Senior Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV l

Office of Nuclear Reactor Regulation Docket No. 50-298 l

Enclosure:

Request For Additional Information cc w/ encl:

See next page i

Mr. G. R. Horn l If you have any questions regarding this request, please call me at (301) 415-1336.

Sincerely, ORIGINAL SIGNED BY:

James R. Hall, Senior Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket No. 50-298

Enclosure:

Request For Additional Information cc w/ encl:

See next page DISTRIBUTION:

Docket File-PUBLIC PD4-1 r/f JRoe JDyer, RIV EAdensam -(EGAl)

ACRS OGC (15B18)

JRHall GBagchi TMcLellan CHawes Document Name: C0095833.RAI 0FC PM/PD4-1 (A)LA/PD4-1 NAME JRHall/vw N CHawes(111rl4

)

DATE

/0 /lY/96 JJO/l[/96 COPY kES/NO YES/N0 0FFICIAL RECORD COPY l

1 Mr. G. R. Horn Nebraska Public Power Company Cooper Nuclear Station cc:

4, Mr. John R McPhail, General Counsel Lincoln Electric System Nebraska Public Power District ATTN: Mr. Ron Stoddard P. O. Box 499 lith & 0 Streets Columbus, NE 68602-0499 Lincoln, NE 68508 Nebraska Public Power District Midwest Power ATTN: Mr. P. D. Graham ATTN:

Richard J. Singer, Manager-Nuclear Vice President of Nuclear Energy 907 Walnut Street P. O. Box 98 P. O. Box 657 Brownville, NE 68321 Des Moines, IA 50303 Randolph Wood, Director Nebraska Department of Environmental Nebraska Public Power District i

l Control ATTN: Mr. B. L. Houston, Nuclear i

P. O. Box 98922 Licensing & Safety Manager Lincoln, NE 68509-8922 P. O. Box 98 Brownville, NE 68321 Mr. Larry Bohlken, Chairman Nemaha County Board of Commissioners Nemaha County Courthouse i

1824 N Street Auburn, NE 68305 i

Senior Resident Inspector U.S. Nuclear Regulai.ory Commission P. O. Box 218 i

Brownville, NE 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011 Ms. Cheryl Rogers, LLRW Program Manager Division of Radiological Health Nebraska Department of Health 301 Centennial Mall, South P. O. Box 95007 Lincoln, NE 68509-5007 Mr. Ronald A. Kucera, Department Director 1

of Intergovernmental Cooperation i

Department of Natural Resources P.O. Box 176 Jefferson City, MO 65102 i

REQUEST FOR ADDITIONAL INFORMATION AMENDMENT 4.1 TO THE SECOND 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION DOCKET NO. 50-298 By letter dated June 20, 1996, the Nebraska Public Power District (NPPD) submitted Amendment 4.1 to the Second 10-Year Interval Inservice Inspection (ISI) Program for the Cooper Nuclear Station (CNS). Amendment 4.1 contains one revised and four new requests for relief from the ASME Code Section XI requirements for NRC review and approval, in accordance with the requirements of 10 CFR 50.55a. The need for these relief requests was identified during the refueling outage ending December 30, 1995, the last refueling outage in i

the second interval. The NRC staff, with technical assistance from its contractor, the Idaho National Engineering Laboratory, has reviewed and evaluated the information provided in the above submittal.

Based upon that review, the staff requires the additional information discussed below, in order to complete its review of the relief requests associated with Amendment 4.1 to the second 10-year interval ISI program for CNS.

1.

Scoce/ Status of Review Throughout the service life of a water-cooled nuclear power facility, 10 CFR 50.55a(g)(4) requires that components (including supports) that are classified as American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Class 1, Class 2, and Class 3 meet the requirements, except design and access provisions and preservice examination requirements, set forth in ASME Code Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components", to the extent practical within the limitations of design, geometry, and materials of construction of the components.

This section of the regulations also requires that inservice examinations of components and system pressure tests conducted during the successive 120-month inspection interval comply with the requirements in the latest edition and addenda of the Code incorporated by reference in 10 CFR 50.55a(b) on the date 12 months prior to the start of a successive 120-month interval, subject to the limitations and modifications listed therein. The components (including 1

supports) may meet requirements set forth in subsequent editions and addenda of the Code that are incorporated by reference in 10 CFR 50.55a(b) subject to the limitations and modifications listed therein.

The licensee, Nebraska Public Power District, has prepared the Cooper Nuclear Station, Second 10-Year Interval ISI Program Plan to meet the l

requirements of the 1980 Edition of Section XI of the ASME Code with the 1981 Addenda.

ENCLOSURE 1

1

j i As required by 10 CFR 50.55a(g)(5), if the licensee determines that certain Code examination requirements are impractical and requests 4

i relief, the licensee shall submit information to the Nuclear Regulatory Commission (NRC) to support that determination.

4 The staff has reviewed the information in the Cooper Nuclear Station, Second 10-Year interval ISI Program Plan, Amendment 4.1, submitted by letter dated June 20, 1996, and the requests for relief from the ASME l

Code Section XI requirements that the licensee has determined to be impractical.

2.

Additional Information Reauired

)

Based on the above review, the staff has concluded that additional information and/or clarification is required to complete the review of i

the ISI Program Plan Amendment.

j 1.

In the amended second 10-year interval ISI program plan, the i

Nebraska Public Power District (NPPD) provided an adjusted weld i

i examination list.

From this list, it is not apparent what adjustments have been made.

Provide a summary of adjustments and the basis for the changes.

It should be noted that examinations j

performed during successive intervals should be performed on the l

same examination areas. Verify that the successive examination l

requirements of the Code (IWB-2420 and IWC-2420) have been l

satisfied.

2.

Relief Request Number RI-06, Revision 2, appears to be an end of interval relief request for reactor pressure vessel weld examinations.

It is unclear whether the information provided is l

based on actual examinations performed in accordance with Code requirements.

If so, NPPD aust submit information on the percentage 1

of coverage obtained for each weld, discuss the limiting factors, i

and provide a basis for the acceptability for the coverages 1

obtained. Discuss the approach used to maximize coverage of the Code-required examination volume (outside and inside vessel l

examinations).

)

3.

In Request for Relief RI-21, Rev. 0, NPPD included the Control Rod Drive Return Nozzle Inner Radius. However, the basis only discusses l

limitations associated with nozzle-to-shell welds.

Provide i

clarification for the subject request for relief relative to inner l

radius examinations performed on the subject nozzles. Discuss the percent of coverage for the CRD nozzle inner radius and the limiting i

factors.

i 4.

For Request for Relief RI-23, NPPD has requested relief from Code examination requirements associated with three RCIC welds in the Torus.

Provide the basis for the code classification of the subject 4

welds on the strainer, when the subject welds are within the torus.

i 4

5

~