l CONTAINMENT SYSTEMS l

PfilMARY CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION 3.6.1.2 Primary containment leakage rates shall be limited to:

l*

a. An overall integrated leakage rete iType A test) in accordance with Specification l

6.8.6, Primary Containment Leakage Rate Testmg Program.

b. A combined leakage rate in accordance with Specification 6.8.5, Primary

~

j Containment Leakage Rate Testmg Program, for all penettstione and all valves i

listed in Table 3.6.31, except for main steam line leoletion valves', main steam line drain volves' and valves which are hydrostatically leak tested per Table 3.6.31, subject to Type 8 and C tests.

  1. c.
  • Loss than or equal,to 100 sof por hour for any main steam isolation y s

I and a combined maximum pathway leakage rate, s gscf per hour for all four I

mein steam lines throcgh the isolation velves who tesked stP, 22.5 psig, or Pa..

d.

'Less than or equal to 1.2 scf per hour for any one li j

when tested in accordance with Specification 6.8.6, Primary Containment j

Leakage Rate Testing Program.

A combined leakage rate of less than or equal to 3.3 gpm for all containment e.

isolation valves in hydrostatically tested lines which penetrate the primary containment, when tested at 1.10 P,.

l APPLICABILITY:

When PRIMARY CONTAINMENT INTEGRITY is required per Specification i

3.6.1.1.

ACTION, i

With:

c

{

a. The measured overall integrated primary conteinmefit'leskoge rate (Type A test) not in accordance with Specification 6.8.5, Primary Containment Leekage Rate Testing Program, or
b. The measured combined leakege rate for all penetrations and all valves listed in Table 3.6.31, except for main steam line isolation volves', main steam line drain i

valves' and valves which are hydrostatically leak tested per Table 3.6.3-1, j

i subject to Type 8 and C tests not in accordance with Specification 6.8.5,. Primary l

Containment Leekage Rate Testing Program, or l

  1. c.The measured leekoge rate exceeding 100 scf per hout for any one main steam Iso!ation valve or a total maximum pathway leakege rate of > 300 scf per hour for I

all four main steam lines through the isolation volves, or

d. The measured leek rate exceeding 1.2 scf per hour for any one main steam line drain velve, or
e. The measured combined leakege rate for all containment isolation valves in hydrostatically tested lines which penetrate the primary containment exceeding 3.3 gpm, Exemption to Appendix 'J' of 10 CFR 50.

's Deletion of the MSIV Leakege Control System wes approved in Amendment No.151 and implemented during the U1 gRIO.

l SUSOUEHANNA - UNIT 1 3/4 6 2 Amendment No. 29, 15/ 158l 9609300189 960923 i

PDR ADOCK 05000387 e

PDR

_ _ _ -.. = _ _

i o

l CONTAINastarr sYSTERAs l

pfmEARY COMTARRAERfr tRAKAGE l

LEAfTING CONDm0N POR OptRATION 3.6.1.2 Pnmary containment leakage rates sheE be Emited to:

e e.

An overed integrated leakage reto (Type A toets in accordance wfth Specification 0.0.5, Primary Containment Leakege Rate Testing Program.

j 1

b. A combined leakage rete in accordanos with Spesincetion 9.8.5, Primary Containment Leekage Rate Teeting Program, for su penetratione and su valves Ested in Table 3.8.3-1, except for main steam Ene leoistion valves *, main steem Ene drein vehme* and c

volves which are hydrostaticaly leak tested per Table 3.6.31, subject to Type B and C tests.

l and a c.

  • Laos then er aquel to 100 ocf per hour f one stee m corr.bined maximum pathway leakage r of 5 300 ocf per hour for as four

' steem lines through the isolation valves when at 2.5 peig) p,.- 4, i

d.

' Lees then or equel to 1.2 scf por fcr any one main steam Ene drain when tested in accordance with

.E.5, Primary Contammes Mate Teetmg Program.

e.

A combined leakage rate of less than or equal to 3.3 gpm for au centainment isoistion velves in hydrostatically tested lines which penetrete the primary containment, when tested at 1.10 P..

l l

APPLICABILITY: When PRIMARY CONTAINMENT INTEGRITY is required per Specification 3.6.1.1.

ACTION:

l winu i

s.

The measured overall integrated pnmary contenment lerAege rate (Type A testi not in i

accordance with Specification 6.8.5, Primary contrenment Laakege Bete Testing i

Program, or b.

The measured combined leakage rate for all penetratione and all velves listed in Table i

3.6.31, except for main steam line isolation veives', main steam line drain valves

  • and velves which are hydrostatically leek tester.1 per Tab's 3.6.31, subject to Type 5 j

and C tests not in accordance with Specifimeon S.8.6, Primary Containment Laakage i

Rate Testing Program, or j

c.

The measured leakage rate exceeding 100 scf per hour for any one main otsam leolation valve or a total maximum pathway leakage rate of > 300 scf per hour for all i

four main steem lines through the leolation valves, er j

i' d.

The measured leak rate exceedeg 1.2 sci per hour for any one main steam Ene drein velve, or i

s.

The measured combined '4akage rate for aI containment isolation velves in hydrostaticady tested. lines which penetrate the primary containment exceeding 3.3

spm, t

j

  • Exemption to Appendix 'J* of 10 CFM 50.

)

SUSOUEHANNA - UNIT 2 3/4 6-2 Anendment No. 727, 129 l

n.

4 a

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION in the Matter of Docket No. 50-388 PENNSYLVANIA POWER &

LIGHT COMPANY I

REVISION TO PROPOSED AMENDMENT NO.153 FACILITY OPERATING LICENSE NO. NPF-22 SUSQUEHANNA STEAM ELECTRIC STATION UNIT NO. 2 Licensee, Pennsylvania Power & Light Company, hereby files revised proposed Amendment No.153 to its Facility Operating License No. NPF-22 dated March 23,1984.