ML20129A194

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-327/96-09 & 50-328/96-09 & Nov. Violation Identified Re Corrective Actions Associated W/Edg Starting Air Compressor Pressure Control Switch Failures
ML20129A194
Person / Time
Site: Sequoyah  
Issue date: 10/10/1996
From: Lesser M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Kingsley O
TENNESSEE VALLEY AUTHORITY
Shared Package
ML20129A195 List:
References
NUDOCS 9610220056
Download: ML20129A194 (4)


See also: IR 05000327/1996009

Text

_

..

.

.

4

October 10, 1996

4

i

Tennessee Valley Authority

ATTN: Mr. Oliver D. Kingsley, Jr.

President, TVA Nuclear and

Chief Nuclear Officer

6A Lookout Place

,

1101 Market Street

Chattanooga, TN 37402 2801

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50 327/96 09 AND 50-328/96-09

NOTICE OF VIOLATION

Dear Mr. Kingsley:

On September 14, 1996, the NRC completed an inspection at your Sequoyah

facility. The enclosed report presents the results of that inspection.

During the period covered by this inspection period, your conduct of

activities at the Sequoyah facility was generally characterized by acceptable

operations, engineering, maintenance practices, and radiological work

{

controls. We are concerned, however, about a violation of NRC requirements

that was identified. Corrective actions, associated with the emergency diesel

generator (EDG) starting air compressor pre;sure control switch failures, were

considered to be untimely and inadequate.

In addition, the root cause

determinations for the 1995 and initial 1996 problems were considered to be

weak in that they failed to identify the defective EDG compressor pressure

switches.

We are also concerned that repetitive equipment problems continued to cause

added operator burden ard impacted maintenance resources, operation's

switching and tagging resources, and da) to day operations.

Problems with

plant material condition indicate weaknesses in maintenance and engineering

,

support.

This violation is cited in the enclosed Notice of Violation (Notice), and the

circumstances surrounding the violation are described in detail in the

enclosed report.

Please note that you are required to respond to this letter

and should follow the instructions specified in the enclosed Notice when

preparing your response. The NRC will use your response, in part, to deter-

mine whether further enforcement action is necessary to ensure compliance with

regulatory requirements.

.?20033

i

!

9610220056 961010

=

PDR

ADOCK 0S000327

0

PDR

A di

_

._

. - .

.. __

___

_

_ . . . _ - - _

. _ . _ .

>

_._ _ _

. _ . _

o

i,

.

'

.

'

2

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of

this letter and its enclosures will be placed in the NRC Public Document Room

.

(PDR).

Sincerely.

,

OriginalSigned by

M.S.Lasser

Mark S. Lesser, Chief

Reactor Projects Branch 6

.

Division of Reactor Projects

1

Docket Nos.: 50-327, and 50-328

License Nos:

DPR 77 and DRP 79

-

Enclosures:

(See page 3)

,

e

,

4)

i

5

l

i

.

'

1

l

-

_

=

i,

.

'

.

3

cc w/encls:

Mr. O. J. Zeringue, Senior Vice President Mr. Ralph H. Shell

Nuclear Operations

Site Licensing Manager

Tennessee Valley Authority

Sequoyah Nuclear Plant

6A Lookout Place

Tennessee Valley Authority

1101 Market Street

P. O. Box 2000

Chattanooga, TN 37402-2801

Soddy Daisy, TN 37379

Dr. Mark 0. Medford, Vice President

TVA Representative

Technical Services

Tennessee Valley Authority

6A Lookout Place

One Massachusetts Avenue

1101 Market Street

Suite 300

Chattanooga, TN 37402-2801

Washington, DC 20001

Mr. R. J. Adney, Site Vice President

Mr. Michael H. Mobley, Dir.

Sequoyah Nuclear Plant

Div., of Radiological Health

Tennessee Valley Authority

3rd Floor, L and C Annex

P. O. Box 2000

401 Church Street

Soddy Daisy, TN 37379

Nashville, TN 37243 1532

General Counsel

County Judge

Tennessee Valley Authority

Hamilton County Courthouse

.

ET 11H

Chattanooga, TN 37402 2801

400 West Sumit Hill Drive

Knoxville, TN 37902

Distribution w/encls:

(See page 4)

Mr. R. R. Baron, General Manager

Nuclear Licensing

4G Blue Ridge

1101 Market Street

Chattanooga, TN 37402-2801

.

_

_

_ _ . _

i

.

.

.

'

.

TVA

4

Distribution w/encls:

E. W. Herschoff, RII

H. S. Lesser, RII

S. E. Sparks, RII

F. J. Hebdon, NRR

R. W. Hernan, NRR

H. L. Whitener, RII

C. F. Smith, RII

D. H. Thompson, RII

J. H. Moorman, RII

D. W. Jones, RII

PUBLIC

'

NRC Resident Inspector

U. S. Nuclear Regulatory Commission

2600 Igou Ferry

Soddy Daisy, TN 37379

NRC Resident Inspector

U. S. Nuclear Regulatory Commission

1260 Nuclear Plant Road

Spring City, TN 37381

1

DrFICF

DRP/Dif

DDP/Pff

DDP/off

nop/pff

DP9/Dif

DRp/pff

!

$!GNATURE

f'Sk

ghv

4[k

NME

sparks:

MShannon

and

RStarkey

ymour

kVan0oorn

DATE

10 /

/ 96

10 / 7 / 96

10 / 9 / Yt

10 / I / 96

10 /

/ 96

10 / 8 / 96

  1. '?

YES

N0

YES

NO

YES

N0

YES

NO

'

_ _ .

__!E__ _..-_"U_

_

, . .

_

_

DFFfCE

DRP/RIl

DRS/PIf

SIGNATURE

NAME

GMacDonald

JBlap

DATE

10 / 9 /_96

10 / J0 / 96

10 /

/ 96

10 /

/ 96

to /

/ 96

10 /

/ 96

COPY?

YES

(NO)

hS)'

NO

YES

NO

YES

NO

YES

NO

YES

NO

OFFICIAL RELut(U COPY

WGUMENI hAMt: 6:\\BR6.5Q\\5t096-09.WP5

I

!