ML20128H989
| ML20128H989 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 02/11/1993 |
| From: | J. J. Barton GENERAL PUBLIC UTILITIES CORP. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| C321-93-2057, NUDOCS 9302170272 | |
| Download: ML20128H989 (2) | |
Text
-
a
- (
j 18 J GPU Nuclear Corporation G U iuclear
- eit:388 Forked River, New Jersey 087310388 609 971-4000 Writer's Direct Dial Number:
Feb ary 11,1993 C'.-93-2057 U. S. Nuclear Regulatory Conunission Att: Document Control Desk Washington, DC 20555
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219 Request for Relief from ASME Section XI, IWA-5214(a) and (b)
Dear Sir:
Reference:
Letter No. C321-93-2048, Barton to USNRC dated February 8,1993 '
On February 8,1993, GPU Nuclear requested schedular relief from the provisions of ASME Section XI, IWA-5214(a)and (b). Subsequent to that letter, a teleconference was held between GPU Nuclear and several sections of the USNRC. This leucc is being written to provide additional information to the USNRC as requested during that teleconference call.
The requested information is provided in Attachment I to this letter. If any additional-information or assistance is required, please contact Mr. John Rogers'at.
609.971.4893.
(Y M
\\V W
Jol J. Bar V' e PresicWnt and Director yster Creek JJB/JJR cc:
Administrator, Region I Senior Resident Inspector-Oyster Creek NRC Project Manager
-I 9302170272 930211' DR ADOCK 0500 9-q
' GPU Nuclear Corporation is a subsidiary of General Pubhc Utikties Corporation -
ii' 0
d ATTACIIMENT 1 The following information was requested by the USNRC staff during the teleconference call held on February 11, 1993:
1.
The crack which was repaired on the Condensate Transfer system was to a 2 inch piping socket weld on a "T" connection to a six inch header. In addition to the repair to the identified weld, a new support was added in the location of the connection to reduce stresses in the area.
2.
By this letter, GPUN requests permission to invoke ASME Code Case N-416 to allow alternative examinations to be performed on a Class 3 component. Specifically, a system inservice leak test was performed and a VT-2 inspection performed. No leaks were noted Additionally, a dye penetrant in>pection was performed to meet the surface examination requirements of the code case. Reliefis requested as the portion of the Condensate Transfer system in question is Class 3 piping, and N-416 allows -'ternative examinations to Class 2 piping.
I
\\