Revised Tech Spec Page 5-1 Superseding Tech Spec Page 5-1 Submitted w/850426 Request to Amend License DPR-71 Re Fuel Cycle 5 Reload
ML20128G087
Person / Time
Site: Brunswick 
Issue date: 07/02/1985
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20128G085 List:
References
BSEP-60, NUDOCS 8507090041
Download: ML20128G087 (1)


Text

(BSEP-60) 5.0 DESIGN FEATURES 5.1 SITE EXCLUSION AREA 5.1.1 The exclusion area shall be as shown in Figure 5.1.1-1.

LOW POPULATION ZONE 5.1.2 The low population zone shall be as shown in Figure 5.1.2-1, based on the information given in Section 2.2 of the FSAR.

SITE BOUNDARY 5.1.3 The SITE BOUNDARY shall be as a shown in Figure 5.1.3-1.

For the release calculations, the boundary for atmospheric purpose of effluent releases is the SITE BOUNDARY and the boundary for liquid releases is the SITE BOUNDARY prior to dilution in the Atlantic Ocean.

5.2 CONTAINMENT CONFIGURATION The PRIMARY CONTAINMENT is a steel-lined reinforced concrete structure 5.2.1 composed of a series of vertical right cylinders and truncated cones which form a drywell. This drywell is attached to a suppression chamber through a series of vents. The suppression chamber is a concrete steel-lined pressure vessel in the shape of a torus. The primary containment has a minimum free air volume of (288,000) cubic feet.

DESIGN TEMPERATURE AND PRESSURE 5.2.2 The primary containment is designed and shall be maintained for:

Maximum internal pressure 62 psig.

a.

b.

Maximum internal temperature:

drywell 300 F.

suppression chamber 200 F.

Maximum external pressure 2 psig.

c.

5.3 REACTOR CORE FUEL ASSEMBLIES The reactor core shall contain 560 fuel assemblies, of 8x8R, P8x8R, and 5.3.1 BP8x8R fuel types. Each fuel assembly contains 62 fuel rods.

All fuel rods shall be cladded with Zircaloy 2.

Each fuel rod shall have a nominal active fuel icngth 150 inches.

l SBR 7%88uBI8'ofBR' P

BRUNSWICK - UNIT 1 5-1 Amendment No.

.