{{#Wiki_filter:-- p May 15, _1985 ] 4 (Doclets Nos. 50-277- . DISTRIBUTION EJordan .and.50-278 ivocKet File _) JPartlow NRC PDR. -ACRS-10 L PDR Gray Files 1' Mr._ Edward G. Bauer,- Jr. '0 ELD BGrimes ORBf4 Rdg RIngram HThompson - GGears Vice President and General Counsel Philadelphia Electric-Company- .2301_ Market Street. Philadelphia, Pennsylvania 19101
Dear Mr.'Bauer:
SUBJECT:
~ DRAFT TECHNICAL EVALUATION REPORT (TER) FOR SALEM ATWS ITEM 1.2 (GENERIC LETTER 83-28)
The staff has completed a preliminary review to assess the~ completeness and -' adequacy of licensee responses to Generic Letter 83-28 Item 1.2. For the
- Peach Bottom Atomic Power Station,- Units 2 and 3, your response was found to
.be incomplete in four-of the areas evaluated. The enclosed TER provides.a technical evaluation representing the staff's initial judgment of the areas evaluated. Pen and ink changes have been made-to the TER by your. project manager to make the wording consistent with our approach. 'In order to preserve our present review schedule, we would appreciate your cooperation in obtaining additional information that will permit us to complete our review. It would appear thit the needed information on your facility could be obtained by telephone conference.within one week of your ' receipt of the DRAFT TER. Ycur project manager will be working with you to ' arrange ~ an acceptable time to conduct the necessary conference. calls. L The information requested in this letter affects fewer than 10 respondents; s therefore. 0MB clearance.is not required under P.L. 96-411.- l . Sincerely,
- %1u1curswu g lLW?*.3M4'f' John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing Ericlosure:
L . Draft TER on Salem ATWS Item 1.2 cc w/ enclosure: r See next page 9 0
- DL
-{ G i;cf. JS '5/ 35 5/ 8505290213 850515 PDR ADOCK 05000277. P PDR j.- k__ _.____________________o
l Mr. E. G. Bauer, Jr. Peach Bottom Atomic Power Station Philadelphia Electric Company Units 2 and 3 cc: Eugene J. Bradley Regional Radiation Representative Philadelphia Electric Company EPA Region III Assistant General Counsel Curtis Building (Sixth Floor) 2301 Market Street 6th and Walnut Streets Philadelphia, Pennsylvania 19101 Philadelphia, Pennsylvania 19106 Troy B. Conner, Jr. M. J. Cooney, Superintendent 1747 Pennsylvania Avenue, N. W. Generation Division - Nuclear Washington, D. C. 20006 Philadelphia Electric Company 7301 Market Street Philadelphia, Pennsylvania 19101 Thomas A. Deming, Esq. Mr. R. A. Heiss, Coordinator Assistant Attorney General Pennsylvania State Clearinghouse Department of Natural Resources Governor's Office of State Planning Annapolis, Maryland 21401 and Development P. O. Box 1323 Harrisburg, Pennsylvania 17120 Philadelphia Electric Company Thomas M. Gerusky, Director ATTN: Mr. R. Fleishmann Bureau of Radiation Protection Peach Bottom Atomic Pennsylvania Department of Power Station Environmental Resources Delta, Pennsylvania 17314 P. O. Box 2063 Harrisburg, Pennsylvania 17120 Albert R. Steel, Chairman Thomas Johnson Board of Supervisors U. S. Nuclear Regulatory Commission Peach Bottom Township Office of Inspection and Enforcement R. D. #1 Peach Bottom Atomic Power Station Delta, Pennsylvania 17314 P. O. Box 399 Delta, Pennsylvania 17314 Mr. Thomas E. Murley, Regional Administrator U. S. Nuclear Regulatory Commission, Region I Office of Inspection and Enforcement 631 Park Avenue King of Prussia, Pennsylvania 19406 - Mr. Anthony J. Pietrofitta, General Manager Power Production Engineering Atlantic Electric P. O. Box 1500 1199 Black Horse Pike Pleasaatville, New Jersey 08232 __.}}