AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-293 UNIT Pilerim 1 DATE
., Jay _13.198L COMPLETED BY_f., HamiltoD TELEPHONE _f617)746-7900 NONTH April 1995 l
DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL l
(MWe-Net)
(MWe-Net) l 1
661.
17
- 669, 2
653.
le 670.
3 666.
19
- 657, 4
300.
20 394.
r 5
St.
21
- 639, 6
562.
22 660.
7
- 154, 23 667.
f 8
595.
24 630.
9
- 654, 26
- 667, 10 660.
26 660.
11 669.
27
- 660, 12 6_69.
20 639.
i 13 669.
29 (18.
r i
14 667.
30 669 15 669.
31 N/A 16 669.
i.
L99TRUCTIO49 On this format, list the average daily unit power level in MWe-Net for each l
day in the reporting month. Compute to the nearest whole megawatt.
I 3
Mql.
VI
e OPERATING DATA REPORT DOCKET NO.
_ 50-293 DATE May 13.1985; COMPLETED BY P. Hamilton TELEPHONE (617)746-7900 OPERATING STATUS 1.
Unit Name Pilgrim 1 Notes 2.
Reporting Period April 1995 3.
Licensed Thermal Power (MWt) 1998 4.
Nameplate Rating (Gross MWe) 678 5.
Design Electrical Rating (Not MWe) 655 6.
Maximum Dependablo Capacity (Gross MWe) 683 7.
Maximum Dopondable Capacity (Net MWe) 663 8.
If Changes occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Roasons:
L None 9.
Power Level To Which Restricted, If Any (Not NWo)
None
- 10. Reasons for Restrictions, If Any N/A Ihis Month Yr-to-Date Cumulative
- 11. Hours In Reporting Period 719.0_
2979.0_
108623.0_
- 12. Number Of Hours Reactor Was Critical 700.0 2437.0 72348.6
- 13. Reactor Reserve Shutdown Hours 0,0 0.0 0.Q.
- 14. Hours Generator On-Line 681.0 7335,8 69904.3
- 15. Unit Reserve Shutdown Hours 0,0_
0,0_
0.0_
- 16. Gross Thermal Energy Generated (MWH)
L299816,0, 4134170.0_ 171085979.0
- 17. Gross Electrical Energy Generated (MWH)
_449570.0_ 1421550 0, 40653764,0 1
- 18. Not Electrical Energy Generated (MWH) 437756.0_
1)66700,0 _39063635.0
- 19. Unit Service Factor 94.f_
81.1_
- 20. Unit Availability factor 94.7 91.1 _
64 3 1
64.4
- 21. Unit Capacity factor (Using MDC Net) 90 8, 71,6 54,2 2
- 22. Unit Capacity factor (Using DER Not) 91.9 72,5 54.9 5 3_
- ll22,
- 23. Unit forced Outage Rate 99 1
1
- 24. Shutdowns Scheduled Over Nost 6 Months (Type, Date, and Duration of Each):
Mon.
- 25. If Shut Down At End Of Report Porlod, Estimated Date of Startup
- 26. Units In Test Status (Prior to Commercial Operation):
forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COPMERCIAL OPERAIION (9/77)
REFUELING INFORMATION The following refueling information is included in the Monthly Report as requested in an NRC letter to DECO, dated January 18, 1978:
For your convenience, the information supplied has been enumerated so that each number corresponds to equivalent notation utilized in the request.
1.
The name of this facility is Pilgrim Nuclear Power Station, Docket Number 50-293, 2.
Scheduled date for next Refueling Shutdown:
August 1986 3.
Geheduled date for restart following refueling: November 1986 4.
5.
Due to their similarity, requests 4, 5, & 6 are responded to collectively:
6.
The new fuel, which was loaded during the 1983-84 refueling outage, is of the same P8x8R design, as loaded the previous outage and consists of 160 P90R8202 assemblies.
In addition, 32 GE68-P80RB282 assemblies were also loaded.
7.
(a) There are 580 fuel assemblies in the core.
(b) There are 1,128 fuel assemblies in the spent fuel pool.
8.
(a) The station is presently licensed to store 2320 spent fuel assemblies. The actual spent fuel storage capacity is 17/0 fuel assemblies at present.
(b) The planned spent fuel storage capacity is 2320 fuel assemblies.
9.
With present spent fuel in storage, the spent fuel pool now has the capacity to accommodate an additional 642 fuel assemblies.
-m
BOSTON EDISON COMPANY PILGRIM NUCLEAR POWER STATION 00CNET NO. 50-293 Oserational Summarv for April 1985 The month' commenced with the unit operating at 100% power until the fourth when a reactor scram occurred as the result of a turbine high vibration signal (Ref.: LER 85-009)..After satisfactory completion of turbine vibration detection equipment repairs, the unit was returned to service on the fifth.
On the seventh, the turbine was removed from the grid at 0352 hours0.00407 days <br />0.0978 hours <br />5.820106e-4 weeks <br />1.33936e-4 months <br /> to investigate a Hi/Lo oil level alarm on the "B" recirculation pump motor, repair a reactor water sample system valve (A0-220-44), and investigate a
(
turbine high vibration alarm (#9 bearing).
After successful completion of L
these tasks, the unit was synchronized to the grid on the same day (seventh) t at approximately 1740 hours0.0201 days <br />0.483 hours <br />0.00288 weeks <br />6.6207e-4 months <br />.
An average daily power level of 100% was achieved on the tenth and essentially maintained until the twentieth when power was reduced to backwash and heat treet the main condenser. Full power was achieved on the twenty-first and maintained through the end of the month, with the exception of the
[
twenty-eighth when a slight power reduction was made to backwash the main condenser.
Safety Relief Valve Challenges Month of April 1995 Requirement: NUREG-0737 T.A.P.
II.N.3.3 I
There were no safety relief valve challenges during the month.
l l
4 L
. m
UNIT SHUTD0kmS AND P0hER REDUCTIONS DOCKET ND.
50-293 UNIT NAFE Pilerim 1 DATE May 13, 1985 COWLETED BY P. Hamilton TELEPHONE (617) 746-7900 REPORT MONTH April 1985 METHOD OF LICENSE CAUSE & CORRECTIVE DURATION SHUTTING EVENT SYSTER CONONENT ACTION TO ND.
DATE TYPEI (HOURS) REASON 2 D0hWI REACTOR 3 REPORT #
CODE 4 CODES PREVENT RECURRENCE 10 4/4/85 F
27.0 A
3 85-009 JJ DET Rx scram on turbine high vibration signal due to inadequate-wibration detector lubrication. Restored L.O. flow to detector and replaced detector.
11 4/7/85 F
11.0 H
I N/A ZZ N/A Shutdown to check "B" RFP Hi/Lo oil alarm and turbine high wibration alarm.
12 4/20/85 S
0.0 H
1 N/A ZZ N/A Reduced power for heat treating and condenser backwash.
1 2
2 3
4&5 I
j F-Forced A-Equip Failure F-Admin 1-Manual Exhibit F & H L
S-Sched B-Maint or Test G-Oper Error 2-Manual Scram Instructions for l
C-Refueling H-Other 3-Auto Scram Preparation of D-Regulatory Restriction 4-Continued Data Entry Sheet E-Operator Training 5-Reduced Load Licensee Event Report
& License Examination 9-Other (LER) File (NUREG-1022)
., _ -. ~
~ - - -,__ _ _.
1 Month April 1985 PILGRIM NUCLEAR POWER STATION MAJOR SAFETY RELATED MAINTENANCE CORRECTIVE ACTION SYSTEM COMPONENT MALFUNCTION CAUSE MAINTENANCE TO PREVENT ASSOCIATED RECURRENCE LER HPCI Connector Overspeed Faulty Replaced connector.
N/R 85-008 on EG/R Trip j
HPCI Rupture Ruptured Age Replaced rupture N/R 85-008 Disc, PSD-68 disc.
HPCI HPCI Turbine Broken Snubber Suspected Rebuilt snubber.
Increased 85-008 Steam Exhaust Shaft Water Hammer Tested the frequency and Line Snubber (Engineering
" mating" snubber duration of the
)
Review in satisfactorily.
exhaust line l
Progress) purging.
1 Surveillance of line after each operation.
HPCI PS-2389A Would Not Trip Balance Level Cleaned and Routine surveillance. N/R Low Pressure Binding lubricated lever -
Switch to be Isolation Recalibrated to replaced during Switch correct setpoint.
EQ project.
Turbine Vibration Faulty Obstructed Replaced detector N/R 85-009 Detector Lube Oil and cleaned lube Orifice oil orifice &
flushed line.
Secondary Dampers Inoperable Faulty Gears Replaced gears.
Plan to replace 85-010 Cont.
AON-82 & 83 dampers.
. Isol.
Increased surveillance frequency.
' Month April 1985 PILGRIM NUCLEAR POWER STATION MAJOR SAFETY RELATED MAINTENANCE CORRECTIVE ACTION SYSTEM COMPONENT MALFUNCTION CAUSE MAINTENANCE TO PREVENT ASSOCIATED RECURRENCE-LER PCIS PS-261-23A Setpoint Drift Unknown Re-calibrated Routine N/R switch.
surveillance.
Switch to be
/-
replaced during-
- EQ project.
Diesel "B" Diesel Loose Fuel Oil Worn Replaced belt as y N/R -- Routine N/R
~
Gen.
F.O. Belt Pump Drive Belt preventive Maintenance maintenance.
Rx Water AO-220-44 Inoperable Did not meet Replaced solenoid.
N/R N/R Sample closure time.
~
System 1
r Post-1001-606A Bad Power Supply Unknown Replaced power Routine. calibration N/R s
Accident
~
supply; recalibrated once/ cycle.
F.or:itoring drawer.
4 4
_-..---_.--_--.A__.___-__----
D
-/
M-x J
y BOSTON EDISON COMPANY t
B00 BOYLSTON STREET BasTON, MAaBACHUS ETTE O2199 WILUAM D. HARRINGTON seweenwees ensessaut enom May 13,1985 BECo Ltr. #85- 086 Director Office of Inspection and Enforcement _
U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attn: Document Control DesN License No. DPR-35 Docket No. 50-293
Subject:
April 1985 honthly Report i
Dear Sir:
In accordance with PNPS Technical Specification 6.9.A.2, a copy of the Operational Status Summary for Pilgrim Nuclear Power Station is attached for your information and planning.
1 i
(
Respectfully submitted, W
D l
W. D. Harrington s
i f
- caw Attachment cc: Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 SE3+