ML20127L416

From kanterella
Jump to navigation Jump to search
Partial Response to FOIA Request for Documents.Record Listed in App C Already Available in Pdr.App B Records Encl Are Also Being Made Available in PDR
Date released: 05/20/2020 Download: ML20127L416


Forwards Summary of Info About Masoneilan Valve Parts.States That J Buechler Will Be Out of Ofc (in Washington) on Wednesday & Thursday & Will Be Back on Friday
ML20127L554
Person / Time
Site: Palisades 
Issue date: 01/09/1992
From: Buechler J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: PETROSINO J J
Office of Nuclear Reactor Regulation
References
FOIA-92-231
Download: ML20127L554 (7)
Summary of 881028 Meeting by Util at Plant Re Nonconforming Parts Received from Sample-Webtrol for Masoneilan Valve. Meeting Brought Together Parties Involved & Discussed Possible Causes of Problem
ML20127L502
Person / Time
Site: Palisades 
Issue date: 11/09/1988
From: Petrosino J
Office of Nuclear Reactor Regulation
To: BRACH E W
Office of Nuclear Reactor Regulation
References
FOIA-92-231
Download: ML20127L502 (4)
Part 21 & Deficiency Rept Re Info on Discovery That Some Masoneilan Valve Parts Supplied by Samole-Webtrol Inc Are Not Genuine.Also Confirms 881018 Telcon Rept Re Notification Criteria of 10CFR21.21(b)(2)
ML20127L452
Person / Time
Site: Palisades 
Issue date: 10/21/1988
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
FOIA-92-231, REF-PT21-88
Download: ML20127L452 (7)
Partial Response to FOIA Request for Documents.Record Listed in App C Already Available in Pdr.App B Records Encl Are Also Being Made Available in PDR
ML20127L410
Person / Time
Site: Palisades 
Issue date: 10/05/1992
From: Grimsley D
NRC OFFICE OF ADMINISTRATION (ADM)
To: CORTE B
COR-VAL, INC.
References
FOIA-92-231, REF-PT21-88
Download: ML20127L410 (9)