._- -__ - _ _-.

PDR c

o DISTRIBUTION

. JUL 2 6 1971 Dockst File (M BWR-1 Reading Docket No. 50-263 R. S. Boyd S. M. Kari V. Benaroya E

Dr. Spencer H. Bush Chairman, Advisory Committee on Reactor Safeguards U.

S. Atomic Energy Commission Washington, D. C.

20545

Dear Dr. Bush:

copies of the following are transmitted f@ree the Committee:

the information of Northern States Power Company (Monticello Nuclear Generating Plant) 1.

NSP letter, dated June 29, 1971, submitting report on errors involving inclusion of isolated pellets of incorrect enrichment in fuel rod loads 3 2.

NSP letter, dated July 2,1971, furnishing additional infore sation to May 12, 1971 letter concerning inoperable main steam line high flow sensors.

t Sincerely;

,,c 5

4 Peter-A. Morris,fDirectori w

Division of Reactor: Licensing

'E

  • ; f,, ^

% I& +

~.qj)fN

Enclosures:

As stated BR

.BWR /DR RI.,, AD:,

I.,__,

oma SMK t

DFKnuth d

j_

.. 7....!.f k.

-.N-

+

  • ~ - - +

DATE >

Forn AEC=818 (Rav. 9-63)

UA.cyggnuDrT RtlNftle.QmG ittID-O' g o g J 4 6

.Y 9211100426 710726

{DR ADOCK 05000263

+

"ym yn PDR M j...:.

j

.i...

-c:

_ ;u.

y ' iM98 J

'