Final Deficiency Rept 84-12 Re Removal of Nameplates from ASME Large Bore Spool Pieces.Initially Reported on 840824. Pieces Will Be Identified,Examined,Repaired & New Nameplates Attached.Completion Anticipated in Sept 1985
ML20127D644
Person / Time
Site: Braidwood  
Issue date: 06/10/1985
From: Miosi A
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
0242K, 242K, 84-12, NUDOCS 8506240291
Download: ML20127D644 (2)


Text

Commonwealth Edison

[

one First National Ptarr, Chcago, Ithnoo Address Reply to: Post Othee Box 767 Chicago, lilinois 60690 June 10, 1985 Mr. James G. Keppler Regional Administrator U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

SUBJECT:

Braidwood Station Units 1 and 2 10 CFR 50.55(e) No. 84-12 Final Report Removal of Nameplates from ASME Large Bore Spool Pieces NRC Docket Nos. 50-456/457 References (a):

E. D.

Swartz letter to J. G. Keppler dated August 24, 1984.

(b):

D.

H.

Smith letter to J. G. Keppler dated October 15, 1984.

(c):

D. H.

Smith letter to J. G. Keppler dated January 17, 1985.

Dear Mr. Keppler:

References (a) through (c) provided information concerning a deficiency reportable pursuant to 10 CFR 50.55(e) regarding the removal of nameplates from ASME large bore spool pieces at our Braidwood Station.

The purpose of this letter is to provide an updated status of the corrective actions being taken to resolve this issue.

This letter is considered to be a final Report.

Corrective Actions Being Taken As previously reported, Commonwealth Edison Company NCR No.

639 and Phillips, Getschow Company NCR No. 1783 have been generated to document this item and track its resolution.

The installed large bore piping spools that do not have ASME NPT nameplates continue to be identified as part of the Material Traceability Verification (MTV) Program.

Phillips Getschow Company is currently in the process of researching and verifying those spool pieces in accordance with their procedure, PGCP-51.

This research and verification will accomplish the following tasks:

1.

Determine the total population of installed spool pieces that do not have nameplates attached.

Verify the identity of installed spool pieces using ]?,

2.

manufacturer's documentation.

q-ga 8506240291 850610 gDR ADOCK 050 6

jun 131985 jo

pf" l'

ij[

a

, -3.-

Field check installed spool pieces without nameplates toglocate. nameplate removal areas.

4..

Perform NDE required by ASME Section III on nameplate removal areas.

5.

Measure pipe wall thickness at nameplate removal areas

.to insure that minimum wall thickness is maintained.

6.

Any required repair to the nameplate removal area will be performed per established procedures.

7.

With the concurrence of Commonwealth Edison Co. and the Authorized Nuclear Inspector, replacement identification plates will be attached to the installed spool pieces.

8.

Resolve on.a case.by case basis,~those spool pieces for which a nameplate or nameplate' removal area can not be located.

As previously identified, it is expected that approximately 600 spool' pieces will be involved in this program.

At present, there are 509 spool pieces-in this' program.

A list will be developed by Phillip's,' Getschow Company of isometric-. drawings outside the scope of MTV.- Spool pieces.not within the scope of MTV that was not1 subject to installation procedures to properly control removal of NPT nameplates will have a_

separate-visual exam to verify nameplate attachment ~.

Current estimates indicate-that1this program will be complete in September, 1985.

Final'results'will be available for NRC review at that time.

In the interim, the implementation-activities -and results to date will be' available for NRC review.

Please address.any questions that you or your staff may

.have concerning this matter to this' o f fice.