ML20127B096

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 921026-30 & 1116-20. Violation Noted:On 921110,procedures Were Not Adhered to in That Survey Not Performed or Documented to Illustrate Impact of Cumulative Dose Rates
ML20127B096
Person / Time
Site: Palo Verde  
Issue date: 12/22/1992
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML20127B087 List:
References
50-530-92-38, NUDOCS 9301120170
Download: ML20127B096 (1)


Text

'

NOTICE OF VIOLATION Docket No. 50-530 Palo Verde Nuclear Generating Station License No. NPF-74 During an NRC inspection conducted on October 26-30 and November 16-20, 1992, a violation of NRC requirements was identified.

In accordance with the

" General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C, the violation is listed below:

Failure to Follow Procedure Unit 3 Technical Specifications Section 6.8 requires that written procedures be established, implemented, and maintained covering the activities recommended in Appendix A of Regulatory Guide 1.33. Revision 2, February 1978 (Reg Guide 1.33).

Section 7 of Appendix A to Reg Guide 1.33 includes operations to limit personnel exposure as an activity needed to be covered by procedures.

Palo Verde procedure 75RP-9RP07 Revision 2.03, " Radiological Surveys,"

implements this requirement and states in Section 3.2, "When Radwaste Volume Reduction (RVR) drums are added to or accumulated within an area, a survey shall be performed and documented to illustrate the impact of cumulative dose rates."

Section 1 of Appendix A requires that procedure adherence be covered by procedures.

Palo Verde procedure 01PR-0AP01 which implements this requirement, states in Section 3.7, " Procedures shall be used, adhered to, and enforced."

Contrary to'the above, on November 10, 1992, procedures were not adhered to in that a survey was not performed or documented to illustrate the impact of cumulative dose rates when two drums containing compacted radioactive waste were placed in the Unit 3 Radiological Control Area yard.

This is a Severity Level IV violation.

(Supplement IV)

Dated at W inut Creek, California this day.of December, 1992 4

9301120170 921222 PDR ADOCK 05000528 G

PDR

..,