Forwards Safety Evaluation Supporting Response to Generic Ltr 83-28 Re post-trip Review Program & Procedures
ML20126L877
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 07/17/1985
From: Varga S
Office of Nuclear Reactor Regulation
To: Farrar D
COMMONWEALTH EDISON CO.
Shared Package
ML20126L881 List:
References
GL-83-28, NUDOCS 8508010102
Download: ML20126L877 (3)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _

. a July 17, 1985 Docket Nos. 50-295 Distribution and 50-304 e $ NR DR Gray file OELD Mr. D. L. Farrar HThompson EJordan Director of Nuclear Licensing JPartlow BGrimes Commonwealth Edison Company ACRS (10) CParrish Post Office Box 767 JNorris Chicago, Illinois 60690

Dear Mr. Farrar:

SUBJECT:

GENERIC LETTER 83-28, ITEM 1.1 - POST-TRIP REVIEW - ZION NUCLEAR POWER STATION, UNITS 1 AND 2 By letters dated November 5,1983 and June 5,1985, Coninonwealth Edison Company responded to Generic Letter 83-28. We have reviewed your submittals and conclude that'your Post-Tvip Review Program and Procedures are acceptable. Our detailed evaluation is contained in the enclosed Safety Evaluation.

Sincerely,

/s/SAVarga Steven A. Varga, Chief Operating Reactors Branch #1 Division of Licensing

Enclosure:

As stated cc w/ enclosure:

See next page t

ORB #1:0 L ,C - #1:DL CParris J$e(r1 '

s $Varoa

! 07/$/85 07/d/5 07/( 5 l

e l

i s taq q'o,

~, UNITED STATES 8 n NUCLEAR REGULATORY COMMISSION

, t cj WASHINGTON, D. C. 20555

% ,,,,,+ July 17, 1985 Docket Nos. 50-295 "-

and 50-304 ,

Mr. D. L. Farrar Director of Nuclear Licensing Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Farrar:

SUBJECT:

GENERIC LETTER 83-28, ITEM 1.1 - POST-TRIP REVIEW - ZION NUCLEAR POWER STATION. UNITS 1 AND 2 By letters dated November 5,1983 and June 5,1985, Comonwealth Edison Company responded to Generic Letter 83-28. We have reviewed your submittals and conclude that your Post-Trip Review Program and Procedures are acceptable. Our detailed evaluation is contained in the enclosed Safety Evaluation.

Sincerely, [ i ff tha,, e Operating Reactors anch #1 Division of Licen n

Enclosure:

As stated cc w/ enclosure:

See next page

Mr. D. L. Farrar Coninonwealth Edison Company Zion Station cc:

Robert J. Vollen, Esquire The Honorable John E. Grotberg 109 North Dearborn Street United States Hous& of Chicago, Illinois 60602 Representatives Washington, D.C. 20515 Dr. Cecil Lue-Hing Director of Research and Development Mr. Michael C. Parker, Chief Metropolitan Sanitary District Division of Engineering of Greater Chicago Illinois Department of Nuclear 100 East Erie Street Safety Chicago, Illinois 60611 1035 Outer Park Drive. 5th Floor Springfield Illinois 62704 Mr. Phillip P. Steptoe Isham, Lincoln and Beale Counselors at Law Three First National Plaza Sist Floor Chicago, Illinois 60602 Susan N. Sekuler, Esquire Assistant Attorney General Environmental Control Division 188 West Randolph Street, Suite 2315 Chicago, Illinois 60601 Mayor of Zion Zion, Illinois 60099 Illinois Department of Nuclear Safety ATTN: Manager, Nuclear Facility Safety 1035 Outer Park Drive, 5th Floor Springfield, Illinois 62704 U.S. Nuclear Regulatory Coninission Resident Inspectors Office 105 Shiloh Blvd.

Zion, Illinois 60099 Regional Administrator, Region III U.S. Nuclear Regulatory Consnission 799 Roosevelt Road l Glen Ellyn, Illinois 60137 )

l