Notice of Violation from Health Physics Appraisal on 801201-12
ML20126G090
Person / Time
Site: Farley  
Issue date: 03/13/1981
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20126G083 List:
References
50-348-80-41, 50-364-80-52, NUDOCS 8103260360
Download: ML20126G090 (2)


Text

-

O t

APPENDIX B 9

NOTICE OF VIOLATICN' Alacama Power Company.

License Nos. NPF-2 '

Farley Facility NPF-8 As a result of the insoection conducted on December 1-12, 1980, and in accordance-with tne Interim Enforcement Policy, a5 FR 6675a (October 7,.1980), the following violation was identified.

Technical S:e:ification 6.S.1 requires that written procedures. be estab-lisned, imolementec and maintained.

Con.rary to the above, written procedures were not established, implementec and maintainec in tnat:

a.

On Novemoer 15, 1930, a maintenance work request for work on a residual heat removal system check valve was releasec for work although the plant conditions necessary for performing this work were not estab-lished as required by plant procedure FNP-1-AP-52, paragraph 6.7.

The valve was not isolated, b.

On August 5,1980, a maintenance work request-for removal of a steam generator blowdown pump in Unit I was released for work although the plant conditions necessary for performing the work were not established as required by plant procedure FNP-1-AP-52, Paragraph 6.7.

The drain line valve was not properly set.

c.

On June 12, 1980, a maintenance work -request was released for work although the. plant conditions necessary. for performing the work were not established'as required by plant procedure FNP-1-AP-52, paragraph 6.7.

The IB waste gas compressor unloader manual. isolation valve was not closed.

d.

On June 6, 1980, the tagging official authorized removal of tags returning the reactor coolant systems and pressurizer liquid and steam

~

~'

samp.le 1.ines at the. primary sample sink without completi.ng the " post-tioning' action" portion' of the tagging operations order as required by plant procedure FNP-0-AP-14, paragraph 6.1.2.

Improper valve position and tag removal sequence resulted insa spill of radioactive liquid at the primary sample sink.

This is a Severity Level V Violation (Supplement I.E).

Pursuant to the provisions of 10 CFR 2.201, you are herecy requitec to submit to.

this of fice within twenty-five days of the date of this Notice, a written state-ment or explanation in reply, including: (1) acmission or cenial of the alleged viola. ions; (2) tne reasons for tne violations if admitted; (3) the corrective b10 3 2 6 03 bot ;

.. -. ~.

steps wnich have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the cate when full comoliance will ce achieved. Under the authority of Section' 182 of the Atomic Energy Act of

.954, as amencec, this response shall :e sucmitted under oath or affirmation.